The most quick-and-easy way to measure your battery capacity is to connect it to a constant current load, then count the time it takes to discharge the battery.
Capacity is the leading health indicator of a battery, but estimating it on the fly is complex. The traditional charge/discharge/charge cycle is still the most dependable method to measure battery capacity. While portable batteries can be cycled relatively quickly, a full cycle on large lead acid batteries is not practical for capacity measurement.
SAE (Society of Automotive Engineers) specifies the capacity of a starter battery by Reserve Capacity (RC). RC reflects the runtime in minutes at a steady discharge of 25A. DIN (Deutsches Institut für Normung) and IEC (International Electrochemical Commission) mark the battery in Ah at a typical discharge of 0.2C-rate (5h ate) for starter batteries. A 60Ah battery would discharge at 12A. No accurate RC to Ah conversion exists but the most common formula is RC divided by 2 plus 16. A short method is dividing RC by 1.9.