I have the 15KW unit on 240V. Never tripped my 30A circuit breaker so not even 7.5KW. These are chinese KW. You need to divide by 2 to get the rest of the world KW
@sempertard
5 ай бұрын
Two things. Please hold he camera still. You're waving it around way too much. And, zoom out a bit. That will help with focus and allow us to look over the object as if we were actually there.
@rjvanderpoel
5 ай бұрын
Great video, can a unit like this be made with a hand lead? We would like to induction heat 1 1/4” diameter bolts and the corresponding nut which has a diameter closer to 2.5”. The wand length we would need would be about 6’ min 10’-12’ optimally. Thanks
@thomaseidst3170
6 ай бұрын
Hi can you make a video how it works and how you connect it I got my from china but it didnt have eny wire connected to plug it into the wall Much love from norway ❤
@MrZetor
Жыл бұрын
Interesting. Did you check out the data sheets of the IGBT modules and the caps? I am wondering whether these components are limiting the output power. If the gates are driven properly, and there is no massive I/C mismatch, I don't see what else it could be, except of course the output transformer.
@chuckmccown8893
11 ай бұрын
I did get the data sheets. Don't recall the details. Bottom line is I that fed these machines with the voltage they specified and got about half the input power consumption compared to what they claim for output power. The factory and the folks behind Amazon reviews never address this issue.
@Rowow
11 ай бұрын
researching online it states its input power is half the output power. Not sure how that works and obviously fraudulent. But seems like the manufacturer is aware of this but simply falsely advertising@@chuckmccown8893
@GurmeetSingh-su5ve
Жыл бұрын
Good job
@wh33lhousediecast
3 ай бұрын
Did you find a chiller that works with this heater?
@ajfreeze215
2 ай бұрын
Does it matter if the input voltage is single phase 220v 60Hz versus 220v 50Hz? I just want one for heat shrink tooling. The 220v ones on Ebay seem to be 50Hz......thank you. AJ
@car9167
2 ай бұрын
Doesn't matter here. The AC is rectified anyways into a DC and then fed to a full bridge high frequency transformer.
@danieloropeza86
Жыл бұрын
Thank you great video..I need a manual. What is the contact you used. Please ?
@chuckmccown8893
11 ай бұрын
Try this one: jxtsd01@163.com
@duanduan3736
20 күн бұрын
how price ?
@paridecontini9773
11 ай бұрын
The consumation current for induction 15kw?
@chuckmccown8893
11 ай бұрын
I don't recall but I think we powered it with 208 and it drew about 7kW so the current would have been 33 amps.
@MuhammadNaeem-i5g
7 ай бұрын
I want to purchase this machine where to buy it
@chuckmccown8893
6 ай бұрын
Ebay
@stanjarmolowicz
11 ай бұрын
gush !.. i just pull out one of those from box and find out that there is no power IN cord nor instruction where to connect the f power . no picture of back panel , instruction is a joke .. contradicting instructions ..talking about '"submachine "!? ...should be there another unit which is missing ??!! i try to get tech support from amazon ....it just boil my blood... wasted about 40 minutes of my life !! would you please just show us where to hock up the power supply cord on back panel ...??? there is to large connectors which is almost self explaining but guessing is not the way to mess with electricity . ... that scattering poor instruction says that this unit should be connected to 220v ac .. but i'm not sure of anything after glancing trough that literature . it effectively strip costumer from trust . i would hate to return it to amazon just for missing info , i want to own induction heater
@chuckmccown8893
11 ай бұрын
You just connect a source of single phase to those two lugs. 240 volts if you have it. And you have to find a screw terminal for a ground. It is certainly not designed to work with our NEC approved wiring in the US.
Пікірлер: 22