1. Do not provide crank bar 2. The stirrups spacing should be maximum at supports 3. The angle. Of hook not designed for 135degrees 4.there is no designed for development length according to 0.87*fy*dia/4toeb*d 5.the Bending wires not tiet properly..... Thank you sir 😍
@bubblespark4265
2 жыл бұрын
stirups minimum space at supports ..l/4 length..centre space more
@cliffriifiu1586
4 жыл бұрын
Great lecturing, thank you.
@JavedKhan-ny3pm
3 жыл бұрын
Can you show an example of 135 deg stirrup bars as most people are using 90 deg. ?
@yxhankun
Жыл бұрын
Would u mind turn on the CC so that words are on the screen be recorded as still picture and we can capture the main mistakes in this lecture without retyping? Please and TIA.
@edrisesmaely
11 ай бұрын
what is the minimum and maximum space of stirrups? in L/4 and in the middle ?
@romanditobongalus7202
3 жыл бұрын
Alayqumisalam. Watching from Philippines.
@paagou3496
Ай бұрын
Crank is not necessary in beams because it will be supported by thousands of bricks and that 90° rings are also not a problem as long as you mixed up the joints alternately
@taffythegreat1986
3 жыл бұрын
When you point out these mistakes, do they rectify them, or do they carry on and pour the concrete ? Nice to ‘now video as I’m in the middle of constructing my own house. 👍👍👍
@nigelunruly3543
2 жыл бұрын
I would like someone to answer the question
@amacdavidz
4 жыл бұрын
its very clear. thanks for the info
@AA-om4vb
2 ай бұрын
Amazing work
@sathishkaruppiah8788
4 жыл бұрын
Thank you for the information brother.....do more videos bro
@tapasbhunia8895
3 жыл бұрын
Sir make a video for design of cantilever beam and reinforcement details and SF, BF
@vijaynarayan1936
3 жыл бұрын
Greetings Sirji, Does the undersize steel and all the mistakes get certified by the building inspector before pouring concrete?
@vikrantparihar5962
2 жыл бұрын
Please make a video on how to check beam shutting line level & plumb bob
@jongmagoncia1735
4 жыл бұрын
That problem should have been prevented if there was an active site/resident engineer on that construction.
@sripalsri
3 жыл бұрын
Good information bro thq alot 🤜🤛❤
@CivilEngineerss
3 жыл бұрын
Welcome 🙏
@hendrabangsawan875
3 жыл бұрын
Waalaikum salam....god !! Salam from indonesia..
@mohammadtalhashah3260
3 жыл бұрын
Dear, crank bar is not provided for shear resistance, but it is provided to encounter negative moment at the support or any position it needed. Secondly in SMRF design code recommends the spacing btw stirrup at the support should be less than 4in. And at the last, according to the code i never see 135 bending in stirrup of the beam. Thank you.
@sampangibalakrishna5276
3 жыл бұрын
Sir why we are provided max steel reinforcement bare in bottom of simply supported beam
@ahmadmustafa3937
2 жыл бұрын
developing lenth kisay banaty hae?
@gurmailchanddhiman4062
2 жыл бұрын
Nice 👍👍👍👍👍 information sir
@ramonplee
3 жыл бұрын
Good commentary. Ur right.
@manjunathkk9425
2 жыл бұрын
Suuuoper Tq u
@aglbakers
3 жыл бұрын
Hello, I have some cracks that have developed. May I send you a video?
@SONUKUMAR-uo4di
4 жыл бұрын
Sir Why captions is not available
@MohamedJamir-pl8nw
3 жыл бұрын
Crank not mostly given instead extra bars are given in L/4 at top reinforcement to counter shear at junctions
@alongzorlymzorlym4032
2 жыл бұрын
Sir evn they did nt put the crank bar in beam why??
@paonamdineshmangang6179
3 жыл бұрын
Sir can you please give some idea of 17.5 feet beam
@rolando3853
4 ай бұрын
You need hooks spliced to beam steel thus tying in beam to columb.
@Faizkakar2233
6 ай бұрын
Yar hum ny gar Ka tamerr Kia Abi beAm kase deay chath Abi tak nhi banaaya hin
@ayoubenaciri
4 жыл бұрын
Thank you Sir 🙏🙏
@selvamv4680
3 жыл бұрын
Column striupps is also not there inside the depth of beam junctions...
@epindarkharkongor7127
2 жыл бұрын
Sir Please .show the drawing of crank bar
@ramonplee
3 жыл бұрын
The problem there is that the engr who signed the design did not see it but he makes guarantee for the building.
@radhikat6496
3 ай бұрын
Good
@royangraham5695
4 жыл бұрын
noted ‼️💯
@Abu-Dhabi786
4 жыл бұрын
Good Job
@DesignReady.
4 жыл бұрын
This is Ileagal .... Report this construction
@MasterCivilEngineering
4 жыл бұрын
True
@shahidghafoor3541
Жыл бұрын
yaar waisay samaj zara be nae aaye. aap asan language use kerain instead of technical terms. ta kay aik normal person be samaj jae. or saath main solution be be bataen, assan basha mai.
@aus2tigran
4 жыл бұрын
top bars transfer load to bottom bars?? that's not how beams work...
@MasterCivilEngineering
4 жыл бұрын
Yes dear
@aus2tigran
4 жыл бұрын
@@MasterCivilEngineering top bars are mainly there to hold up the stirrups, or for negative moment, or to reduce the neutral axis depth. The bottom bars resist the tensile stresses from bending action
@MasterCivilEngineering
4 жыл бұрын
Stirrups are used for shear while top bars are used for negative moment at supports
@DesignReady.
4 жыл бұрын
This building will collapse
@ramzysaikadatu7350
4 жыл бұрын
The hook. That’s one of the mistake
@MasterCivilEngineering
4 жыл бұрын
Right bro
@MasterCivilEngineering
4 жыл бұрын
Video solutions of civil engineering questions here
@epindarkharkongor7127
3 жыл бұрын
Thank you sir do more vedio
@bulbulebaagemadina
4 жыл бұрын
Walaikum assalam bhai
@noslen6077
3 жыл бұрын
You know why it's all mistake? Ba cause some already it budgets is in the pocket of the foreman
@johnbrando2666
8 ай бұрын
Not ok amigo
@Canada4Israel
10 ай бұрын
Okay
@williamsgiancarloyenquecar189
3 жыл бұрын
el gancho de los estribos no es correcto
@rickyguade3304
4 жыл бұрын
Okay okay okay okay
@sathishkaruppiah8788
4 жыл бұрын
All of them are mistakes.....
@MasterCivilEngineering
4 жыл бұрын
Beam is full of mistakes bro
@viosog9661
3 жыл бұрын
Etrierii nu sunt corecti , nu ai etrieri in noduri ,ciocuri la barele de la grinzi