Probably back emf generated by fan rotation hitting compressor. Can be fixed with double pole contactor with fan hot moved to bottom. Isolates fan from compressor.
@Garth2011
11 ай бұрын
Looked like an ECM fan motor. Same applies?
@HVACRDUDE
11 ай бұрын
Winner winner. 🏆
@brunoshvac2578
11 ай бұрын
That is not an ECM fan motor on that unit. The it’s definitely a known issue. With TRANE/ American Standard units going back to 2020 16 SEER units and 14 SEER. Seems like we are getting more calls about this on newer units now. We’ve had about 4 this summer so far. Their is a bulletin about this from AMS/ TRANE engineering department. It’s been mentioned already. Change to 2 pole contactor and move run winding for fan motor to L2 from T2. Same way all Carriers come factory wired. Engineering dept states it’s a back EMF issue.
@countryfriedhvac
11 ай бұрын
Thanks for the learning! I’ll try this next time I run up on this issue
@throttlebottle5906
11 ай бұрын
yeah, back EMF from one or the other, probably compressor/cap combo hitting the fan motor, that would make the higher pitch bang, especially since it's hooked to giant noise emitters (the top and blades). compressor is generally a dull low tone thump.
@jamesvojir8988
11 ай бұрын
It's caused from the fan motor. Disconnect the compressor and it'll still make the noise upon shut down. Usually only does it when the pad is not on regular ground but on rocks or cement. Tighten the fan mounting bolts as tight as you can by hand and put vibration pads on all 4 corners of the unit. It's worked every time.
@nikcook2340
11 ай бұрын
Nice timing with the hand tap on the downstairs condenser!
@lonewanderer9872
11 ай бұрын
Forever grateful for your a videos, first summer as a service tech and you ans your videos have helped so much. I see so much wrong in a majority of homes I work home , super neglected and i get overwhelmed. I end up at your channel, thank you sir!
@joeyf504327
11 ай бұрын
there is another youtube tech who installed Carrier and had the same customer complaint. A loud bang when turning off. He installed a delay timer to turn the fan off a few seconds after the compressor shutoff. It worked well. The noise was completely gone. Just an anomaly that the one specific unit resonated when turning off. Staging the shutdown solved it
@jeromes58
11 ай бұрын
Your customer should hear my water furnace compressor at turn off. 14 years old and it has hammered at shutdown from day one. Still running fine. Great videos Ted
@Big-Rouge
11 ай бұрын
I had a Trane 5 ton unit installed in my new construction 8 months ago and it has the same loud noise when the unit shuts off! The unit runs great and really cools my house in southwest Louisiana. It has been really HOT and Humid down here this summer too!
@mikenonameneeded3485
11 ай бұрын
I'm in Lake Charles. I commented also
@Straycurrent
11 ай бұрын
Although there may be some back emf factor with these units causing the fan to jerk, I believe the actual clunk can be coming from a loosening of the fan blade shaft bolt. I observed this happening with an Am Std Silver Series CU about two years ago. The noise started like the sound of these units and gradually worsened over a week or two. It eventually resulted in the fan blade falling off the shaft and damaging the compressor discharge line as well as the blade itself. .
@stress_headache
11 ай бұрын
You service some absolutely beautiful homes.
@chatrkat
11 ай бұрын
Nice to see a pair of new Trane condensers setting side by side.
@davidspade7654
11 ай бұрын
Always honest and professional love it brother ❤ not every call is a win but we stay professional consistently finished my last call as a recall was out there last week for annual maintenance she calls us today saying system is down come out right away she explained to me she had a pest control out there two days ago the pest control guy left the power off in the crawl space which killed power to the unit always feels good to be Superman flipping switches
@elBusDriverKC
11 ай бұрын
I hear Copeland scroll compressors on Lennox units shut down hard all the time like that. Just a lot of mass moving around then all of a sudden stops.
@TheBaum1
10 ай бұрын
Dam for the money you have to spend on these units, it really shouldn’t make any unusual sounds or vibrations cycling through a shut down sequence ? that would probably indicate a less than optimal life span of trouble free usage down the road? It’s like buying a new car with a bad bearing in the engine, it’s all good until it runs out of the manufacture warranty down the road and then it’s on your dime. Just change out anything & everything in that unit under the factory warranty… until it sounds right. make it run like the other unit next to it does. Kinda hard to tell a customer that “oh it’s ok that’s normal”, when you have a comparison unit sitting right next door and it’s working without the issue.. When you’re retired and done and that unit kicks the bucket down the road , their in for more downtime and aggravation..
@khakiswag
11 ай бұрын
Normal. My XR14 has been doing that since day 1. Running trouble free for 8 years and no problem handling the 100 degree days we’ve been having.
@zeldamoore8371
11 ай бұрын
My trane has noisy shut off too. Almost 3 yrs old now & no issues. Just different from other brand I had
@sknight0391
11 ай бұрын
The good ol' 410A jolt. 😎👍
@Eddy63
11 ай бұрын
Good little vid Ted ... Thx
@wtgkb8
11 ай бұрын
My American Standard has that compressor shutdown rattle too, but hasn't been an issue for the 9 yrs I've had it make that sound
@mattmishoe157
11 ай бұрын
As I was watching intently and turning the volume up, I got scared I was gonna get a full screen scary face and scream from back in the day. 😂
@cyberlight22
11 ай бұрын
That was funny right as you touch the second unit turned on Great video
@lucidphysics7891
11 ай бұрын
ive been working with newer compressors. the ones i learned on in school dont necessarily make that noise because they are older units to be trained on. on the case with the newer compressors, they all stop like that. i just worked on a year old system and when i pulled the disconnect it make that exact same noise. its a manufacturing issue as far as im concerned.
@mikenonameneeded3485
11 ай бұрын
I have the same 4 ton Trane XR. Installed 2015. Mine makes the same noise. No worries here.
@j.rcoker9051
11 ай бұрын
My Rheem does the same thing as the smaller one...always has and actually sometimes its louder.
@hvacjay3201
11 ай бұрын
Had this issue and trane sent me a 2 pole contractor and I was skeptical but it did work. No more noise on shut down.
@quaarjet
11 ай бұрын
The smaller unit seems like the compressor shut off bump is louder.
@jeffsworld2
11 ай бұрын
I have a new 3 year old system, not a Trane, that does the same thump. Mine is more at start up. I questioned it as well and was told that all the new style compressors will do this, clutch noise I believe
@danwittels5542
11 ай бұрын
I've never seen a Goodman do that! 😅
@c.blakerockhart1128
11 ай бұрын
Goodman high static heat pumps with scroll compressor is louder than that is.
@criticalw88
11 ай бұрын
“Dad-gum Goodman”!
@unorthodoxridez
11 ай бұрын
Do you think that the compressor could be loose and when it torques on shutdown that it moves slightly? That definitely doesn't sound good (acceptable) on the first unit especially if it's new. I'm not in the business but as a consumer if I paid to have that put in I wouldn't want it to sound like that.
@camac57
11 ай бұрын
Mine makes the same noise. Same unit. Six years old. No problems
@watermanone7567
11 ай бұрын
Are the compressor mounts o.k. and not split. I use to see this on some refrigeration units. Thanks
@erinm9534
11 ай бұрын
Good job ted❤😂🎉
@XGamesJ6
11 ай бұрын
I often get a whistling sound from my system after it satisfies. I assume it's the pressure equalizing in the lines/coils.
@uxwbill
11 ай бұрын
That definitely doesn't sound unusual to me.
@Channel-cm7yc
11 ай бұрын
Scroll unloading is what it sounds like to me? My Amana does the same exact thing and it’s 10 years old and has always done it.
@Paul-IE-Repairs
11 ай бұрын
that sounds like normal the valve noise. When the compressor stops there is still head pressure and motor will shutter back and forth a few cycles until the opposing forces equalize and the motor stops in a neutral position.
@WayneBain
11 ай бұрын
I have one that makes 10-12 knocks on shutdown. Sounds like someone threw a handful of rocks at it. My service company ordered me a new compressor (scroll) but said to wait until the old one failed as it was working perfectly and using no more electricity than a new one. That was three years ago and it still works perfectly just noisy on shutdown. I don't know if it is a rattling seal or what but pressures are perfect. I just knew it would throw in the towel a long time ago but it has not.
@irisbaez1972
10 ай бұрын
I bought a brand-new Amana 4 ton, and it does the same noise at stop. I thought was the fan blades, but I stand closed to the compressor and I hear from there and it feel like clan,clan,clan when is stop. it looks like the compressor when it stop. Maybe cause its bran new and the piston inside do that.
@onenikkione
11 ай бұрын
We had a Trane 5 ton installed in Jan 2021and ours makes a rattle/noise when it shuts off.
@tc7922
11 ай бұрын
Compressor sounded fine on shut down… sounded like the fan motor to my ear … I have had the same complaint from customer that has a Trane package unit.
@jtalonrider4769
11 ай бұрын
Some customers are annoying 😂😂
@myHVAClife
11 ай бұрын
We get those calls all the time, nothing wrong. Just homeowners! Sounds fine to me.
@clintgray1623
11 ай бұрын
Looks like the installers could turn some of the units 90 degrees to allow for easier service, the control panel and service area, if heat pump would be a lot easier to service
@mariachurch9275
9 ай бұрын
I have a 2023 amer Stan silver that started doing this 4 wks after install. The installer tells me its normal with the new compressor design. I wish they could do something to quiet it down. It runs quiet and the entire system with blower installed. It’s going to get used a lot in Az. Kicker is if the rotary designed compressor wears out the entire compressor needs replaced. 10 year warranty I hope has me covered if it happens.
@powerstorke03
3 ай бұрын
Do you ever have issues with the scroll coming apart in the compressor?
@stevekline5608
11 ай бұрын
My Trane is doing same thing. My Tech said if I installed a soft start it would reduce the start up and shut down noise. It didn't help at all. Did I get scammed?
@gregnettles3677
11 ай бұрын
I have the same 4 ton unit does the same thing had it installed in 2017 zero issues
@pya102
11 ай бұрын
We have a Trane installed in 2018 and makes the same noise. If you find the cause/remediation please share. It’s mostly a mild annoyance.
@c.blakerockhart1128
11 ай бұрын
Sadly it is just the sound they make on shut down. The compressor becomes torqued in one direction while running and the sound is the compressor immediately releasing the torque.
@Sesamestreet9080
11 ай бұрын
Carriers have problems with scrolls when they shut off they make a thud sounds it’s because a valve is worn inside the compressor
@robalexander7348
11 ай бұрын
Ted, Please don't oil that squeeky hinge on your work van, we all look forward to that squeek when you arrive at the next job, and open the door 😀 👍 Au
@United_HVAC_and_Fans
11 ай бұрын
Some people amaze me
@dimbag1
9 ай бұрын
Need to put some W D 40 on that door hinge giving chevy a bad name big Ted.
@wmalden
11 ай бұрын
My 2014 Bryant 3 ton makes the same noise on shutdown. No problems. Normal.
@nekochristmas
10 ай бұрын
I just got a brand new Rheem 5-ton 19seer installed and the compressor makes a chattering sound when it turns off, hopefully that's normal operation 😅
@fastzombie1
11 ай бұрын
Even the Copeland scrolls make that hissing noise when they shut down.
@davo912
11 ай бұрын
open you listen ears..it was no hissing noice
@fatalberti
11 ай бұрын
had my compressor on my new 2021-22 trane unit go out at 13 months. original compr indicated made in louisiana. replacement was proudly made in china. maybe pandemic conditions resulted in reduced quality control on new trane. but if a trane laid down after a year can you expect any mftr to be reliable?
@applianceman6009
11 ай бұрын
Trane does not use Chinese compressors. Some have LG compressors, and those are made in Korea. Most include an Alliance, and they are still made in Louisiana from what I have seen. Maybe yours was a certain batch.
@cthomaspac
11 ай бұрын
The scroll compressor , upon shutdown will make that noise . It's the pressure in the system that actually pushes the scroll backwards for a brief moment. It is Totally normal. On the trane csha scrolls (15 ton) upon shut down they actually turn bakwards for up to 2-3 seconds. Take is easy bro.
@ronaldclark8187
11 ай бұрын
That sounds like the reasonable explanation. The early type rotary used to tick while equalizing. Back EMF,resonance,moving loads around.IDK about that shyt.
@HonestyHVAC
11 ай бұрын
Yeah idk what everyone is talking about the fan making the noise, bigger scroll compressors do it unmistakably so that’s probably why I know it’s the compressor
@The.Lone.Wolf.
11 ай бұрын
Backpeddling or back spin upon shut down mine does that too it's a scroll compressor kinda annoying but what're you gonna do....
@hvacrefrigeration5204
11 ай бұрын
Never seen that too, should call to tech support to get some opinion about it.
@damonried1720
6 ай бұрын
Yes, the noise may be normal, however, what is CAUSING the noise? Is it from 'fluid shock' when a valve shuts closed suddenly?
@jameskoch7780
11 ай бұрын
Hi Ted do you know or have talked to Curts the HVAC GUY?
@SteveM-426
11 ай бұрын
I have a Goodman that makes those sound like a mouse with slippers! LOL!
@mistervacation23
Ай бұрын
Mine makes a thump sound when it shuts off is it serious?
@roynewling6599
11 ай бұрын
I had one do that it was the rubber grommets on the anchor bolts
@mattluongo7763
11 ай бұрын
That was the fan motor, not the compressor.
@c.blakerockhart1128
11 ай бұрын
That's just the way a scroll compressor sounds. It's spring loaded from the sound of it.
@davo912
11 ай бұрын
problem is it didn't do it when it was new did it? Only because it's a Trane does he think its ok.
@austinanderson32
11 ай бұрын
Have a American standard which almost a year old. It does the same thing also
@normandriscoll3320
11 ай бұрын
Normal sound for a rotary compressor. Their valves behave differently for a reciprocal compressor, and this is perfectly normal.
@joshmc4328
9 ай бұрын
I for one do not believe it's normal, maybe with these two-stage compressors nowadays but it is definitely not normal on a basic compressor, I would like to find a way to drop down to first stage before shut down, I can tell the difference in sound from first to second stage, I have a f****** geothermal unit and as loud as f*** in the house... makes you want to run and go look and make sure you ain't got no lines blown off an flooding your house...lol
@rubberman2006
11 ай бұрын
Hate to see his electric bill having 2 units cooling that house.
@joeshearer1247
11 ай бұрын
Its that fan thump noise I can make it stop doing that with a double pole contactor
@ChingusTheOneAndOnly
11 ай бұрын
Joe knows , I remember that video
@danwittels5542
11 ай бұрын
That's interesting, maybe Ted will try that, I'd like to know if it works.
@jasonshearer1870
11 ай бұрын
Yup, you should make a video on that
@lucidphysics7891
11 ай бұрын
sure would love for you to show me, I always want to learn how to get a customer off my back lol. please make a video on your solution to prove your hypothesis.
@bills6946
11 ай бұрын
I only install double pole contactors when they need replacing
@Austin23191
11 ай бұрын
I added a compressor blanket to my AC yesterday and it cut down on the noise considerably.
@KarlWatson-ro9ms
Ай бұрын
So youre telling me they designed that ac unit to make that kind of noise? I cant believe that. If the customer had the opportunity to “test drive” the unit before they purchased it nobody would buy one. I spent $20k to have 2 american standard units installed and they make the same noise which I was told is normal. I will never purchase that brand again or use the contractor that sold them to me.
@garrettrush1467
11 ай бұрын
Completely normal. However you would think nowadays they would make even basic compressors quieter. They have the technology just don’t want to spend the money.
@111000100101001
11 ай бұрын
Sadly for customers the mfg keep trying to cut cost out and keep function. Notice how much lighter a same capacity, new compressor is vs one from 15yrs ago?
@chetmyers7041
11 ай бұрын
2:16 Smaller unit switches off with clunk. 3:33 2nd unit makes no thump sound.
@finallyanexpert.301
11 ай бұрын
I usually have to be standing around 15 feet away to isolate the compressor vs fan sounds but from the video it sounds like something is missing from the functionality of something 🤷🏻♂️ if they donate that unit to my not for profit conditioned space laboratory I could send them some stickers or maybe a hat
@Ageehvac
11 ай бұрын
The Hvac G.O.A.T
@BurtBartlow
11 ай бұрын
Scroll compressor. That's what they do.
@Kartertheblackmamba
2 ай бұрын
Sounds fine lol. They just don’t understand how their units work…
@timcastilo6962
11 ай бұрын
Holy moly put some WD-40 on your van door hinges 😂
@Ageehvac
11 ай бұрын
I had a damn goodtime on a trane system with a bad recip the other day....
@joeduck348
11 ай бұрын
Omg. Good luck with comment sir 👍
@mikeniehaus7872
11 ай бұрын
My Trane XR makes the same noise. It is only a year old.
@DarkDraconX1
11 ай бұрын
Damn.
@rcpasc1948
11 ай бұрын
My 4 ton does that.
@MOAONAABE
11 ай бұрын
my carrier is 2 years old and it clunks when it kicks off, and it clunks when it turns on. it replaced a trane i installed in 1990
@Perly53
11 ай бұрын
My next door neighbors newly installed Trane makes a loud clunk every time it shuts off. It doesn't seem normal to me.
@DanTheManIOM
18 күн бұрын
should a newly installed compressor make noise on start up ? like cavitation or a "rod knock" on start up ? I'll have to record it, BUT, I am not getting the same idiot who came out the last time. Yes, coincidently I had a FIRE in my fuse panel starting at the AC circuit breaker WHILE he was here working on the unit.
@ntsecrets
11 ай бұрын
Play a video of a Goodman turning off and he will feel better
@Garth2011
11 ай бұрын
Interesting...if those were mine and under warranty...I would for sure be communicating with Trane ! Yes very minor but NOT really normal so Trane should correct it. By the looks of previous comments, maybe it should have a dual pole contactor?
@TheBrad605
11 ай бұрын
My brand new ac unit makes same noise when it shuts off.
@FB-111A
11 ай бұрын
I have two carrier units that makes a similar noise on start up. Both units were installed when the home was constructed in 1999. They continue to perform effortlessly in the humid Louisiana climate.
@OnusBones
11 ай бұрын
Any possibility the compressors are loose on their mounts, and just need to be tightened down a little?
@HVACRDUDE
11 ай бұрын
😅😅😅😅😅 wow
@c.blakerockhart1128
11 ай бұрын
Not very likely. They are torqued at the factory. Occasionally that may be the case, but not very likely. It is the sound that a scroll compressor makes when shutting down. The noise could actually be reduced by loosening the bolts just a little, but make sure to dab a bit of rtv across the bolt to prevent it from backing out more.
@hvacwonders7081
11 ай бұрын
What are they talking about? That wasn’t that loud shutting down
@noahholt482
11 ай бұрын
She makes a lot of noise when satisfied ey
@alanwagen
11 ай бұрын
My neighbors Trane makes the same noise.
@negan454ss
11 ай бұрын
Scroll compressor are noisy on shutdown
@krob08
11 ай бұрын
Trane has got be one of the best ACs out there.
@vernondouglas4425
11 ай бұрын
What a waste of a call
@irisbaez1972
10 ай бұрын
Big mistake talk in the moment the noise will come. Don't talk if you want to show any noise. WOW
@silverS70
11 ай бұрын
I would have marked the units or disconnects so you and the homeowner knows which is for what floor. Should have been done at install.
@mrjprice3
11 ай бұрын
My five ton does that same thing. I only hear it in the basement where the line set is exposed.