Try this if you like using a 3-way stopcock to administer adenosine: instead of swiveling the stopcock between syringe pushes, put it in the “all ports open” position. First give the adenosine, then the flush. No swiveling needed. Remember to hold pressure on the flush syringe while the adenosine goes in, or the adenosine can back up into the flush syringe. Then hold pressure on the adenosine syringe when flushing.