as a SAP2000 beginner, I find this video very helpful. Keep it up brother.
@anastaha2438
Ай бұрын
Hi sir, say inclined rafter and straight IPE bottom beam both connected to column flange , in realltiy the bottom straight beam will be shifted down because of joining plate between rafter and column flange to take space , so in reality the beam is shifted down , shall this be reflected also in sap?
@chinyerenwankwo1245
4 жыл бұрын
Great video. Please what's the aim of assigning compression limits for some members?
@Ricardo-hm1dl
4 жыл бұрын
compresion limit set in 0 implies that the element only develope tensile but is needed to activate the nonlinear analisys
@aniliqbal6654
5 жыл бұрын
why did you release release M22 and M33. Please explain
@Ricardo-hm1dl
4 жыл бұрын
because those bars are supposed to be articulated. but it is not necesary to release both of them generally it is enough with M33 for beams