I like him!....not monotoned and also funny!......thanks for sharing friend!
@prodoommania4157
3 ай бұрын
Have you considered asking him out?
@rafaelortiz-er7yj
2 ай бұрын
@@prodoommania4157🎉🎉
@coldfinger459sub0
Жыл бұрын
Even though I attended these classes and seminars, I still come back and re-watch the videos
@elijahbasika3126
Ай бұрын
Thankyou Sir for your service and teaching... From Papua New Guinea
@leonelvelazquez9224
Жыл бұрын
As a young Technician in the trade I appreciate you sharing your knowledge about Static and Air flow, taking notes to implement it in the field... Thanks for sharing!!
@danwesten2771
11 ай бұрын
Wait til the statics way off but the customer doesn't want to pay to change it by changing the duct work. The problem will always exist for everyone who is unlucky enough to be dispatched there.
@acrservicesmathewr7565
Жыл бұрын
This was a great teaching video. Static is so misunderstood and can confuse even the more experienced techs
@elijahgoodman3140
4 ай бұрын
This guy is super smart and funny as hell! It must be fun working with him.
@randywheeler1223
Жыл бұрын
Mr. Henderson is a great guy !!! Very Intelligent man and always keeps moving forward. From Prosperity SC Randy Wheeler Randy Wheeler
@stephenacman3244
Жыл бұрын
Such a good teacher!! thank you
@Elisummit845
Жыл бұрын
@bryan you gotta put him on the main stage next year 🤣. I watched all classes virtually this year, no idea how I missed this class. Hope to see you in person next year 🙏🏻
@tomkacandes8286
Жыл бұрын
Fantastic instruction, thank you
@tc7922
Жыл бұрын
Thanks for the education Mr. Henderson. I am grateful!
@natepeterson7145
Жыл бұрын
Good job, learned me some airflow!
@Wdbx831
Жыл бұрын
Really great presentation, very informative - thanks!!!! As an aerospace engineer, my only question is how do ever find a service tech or installer who is qualified in duct work. I am considering buying the equipment and just doing it myself. I wanted to get static pressure checked along with a superheat measurement (piston system) and not one of the three service techs I had for an assessment even had a working manometer. So truly, any advice would be appreciated, how do you find a service tech? I did try confirming they did the static pressure measurement when making a service appointment only to find they didn't carry the manometer or it didn't work or they had no clue how to use it. I live in the Daytona Beach Fl area if you have any folks you know. Thanks!!! RZ
@winstagram1785
5 ай бұрын
Why isn’t this one of your top videos! Airflow, airflow, airflow baby!
@Elisummit845
Жыл бұрын
Sure already bought my tickets for next year's 🥳
@rafaelfelix1072
Жыл бұрын
Outstanding presentation. Thank you for sharing
@fisheye42
4 ай бұрын
25:34 - Rule of thumb for correct Amp draw on PCM vs ECM (X13 and Constant CFM) motors.
@Angel.Gabriel.Macias
Жыл бұрын
Cool video! 💯
@staycoolwithrob
Жыл бұрын
Thanks for this🎉
@rogerweisse1213
Жыл бұрын
Well done thank you
@performancehvacr6629
Жыл бұрын
A Constant Torque would ramp up and have a higher current draw with restricted airflow? If they had a lower current draw with restricted airflow, they wouldn't fail like they do on undersized ductwork?
@chuckgillard9771
Жыл бұрын
I like to measure static and use the fan. Table. If there is a better/easier? I'm told don't trust a anemometer. Could I measure a total airflow with like a reverse blower door?
@michaelmorassi4953
Жыл бұрын
Do you have any videos that use air flow as a diagnostic for secondary heat exchanger issues?
@oversober
10 ай бұрын
TAB work is interesting but the most stressful job in all of HVAC
@eskinderteshome3720
Жыл бұрын
I have questions why my air return sound like earthquake when it started to blow cold air
@LispyJesus
Жыл бұрын
How does that 3-5 foot rule work for an upflow on a furnace in a basement? Most common set up here and they just use a plenum. There’s no room to run 3-5 feet up before splitting generally
@anthonybernier9952
6 ай бұрын
To my understanding you check static pressure somewhere after a 3 foot run of duct not a the top of the unit if it turns right away like you stated.
@LispyJesus
6 ай бұрын
@@anthonybernier9952 depends on if it’s a furnace with a coil or air handler here. On Air handler the blower performance charts static includes the coil in it so 3-4 out works as they are generally horizontal in attics here for the most part. More common is a furnace with a Cased coil plopped on top. I’ll just go between the furnace and coil with one proble and hit the return no filter the other for my static there
@anthonybernier9952
6 ай бұрын
@@LispyJesus yes, you are correct. I guess I was just talking about a air handler in that case and should’ve specified that.
@DaríoMartínez-w6w
5 ай бұрын
That's when you use a 90 degrees tee
@Elisummit845
Жыл бұрын
@45:25 I actually saw that on a job 🤣
@asperbergers7136
5 ай бұрын
@4:45 safe to say this guy knows what he’s talking about.
@pastypatsy7515
Жыл бұрын
Hello 👋 So I am Getting all sorts of white looking powdery stuff and like little fiber looking stuff inside the house. And I mean all over and if you clean it it just is back within a day. It looks like debris of some sort and definitely coming from the hvac air duct vents. The vents were “supposedly” cleaned by FOLKS but this stuff remains. They put an electro static filter in the furnace and took out the paper replaceable filters from both air intakes vents. Is this normal? This stuff is literally everywhere and is bothering my skin and lungs. If I take a flashlight and look it’s everywhere