Fixed my problem perfectly. It took three cycles of waiting for the error, turning off and on. Eventually it ignited. Thank you so much you saved me a support call.
@outdoormcbain2346
4 жыл бұрын
Thanks for the video. Saved me some money!
@1947froggy
4 жыл бұрын
You helped me before, same issue. Heater shuts off b4 reaching set temp (104f) . It fires up and heats from ambient pool water temp to about 100f and shuts off. I have replaced both the temp sensor near the inlet outlet pipes (part of the Hayward heater) and also the sensor that is stuck into the pvc pipe and goes to the electronic control circuit board (that goes to an indoor control panel). So indoor panel calling for 104f but heater shuts off at 100f. I twister the dial on the heater a few times and left it at max setting. Funny thing is the first day I put the new (PVC mounted) sensor it it worked and went up to 104f and shut off) The sensor is a factory Hayward brand. Is there some other sensor or temp. setting dial or else that I can clean or fix? THANKS! Froggy.
@mchaelhron279
6 жыл бұрын
Good video. ty. i had as SNS problem ( sensor) on the display. Changed the sensor & the unit fired up right away & ran for a day. Then it went back to SNS on the display & would not light again. Any ideas on the problem? Ty.
@Askthepoolguy
5 жыл бұрын
Sometimes there is more than one part that needs to be replaced to "reset" the system. There could also be something ancillary going on that is damaging the sensor even after it is replaced. Best to go step by step through the process of a heater firing, and exhaust to determine where the issue could be.
@scottsugarbearpearson518
7 жыл бұрын
any chance you have a video of a "safety loop test" on an old LAARS Lite ? (circa 1999) changed the water sensor,it fired up on test,won't fire up now....and no buzzing before it lites like before,i was told to do a Safty loop test
@stevemoyer4009
6 жыл бұрын
Can u please explain when u say flip it on and off do you mean the main gas valve or the on /off button on the heater thank you
@Askthepoolguy
5 жыл бұрын
Flipping it off and on would be toggling the heater on/off switch. It's also a good idea to try the breaker if you have electronic components - and the gas line at the heater and the house (sometimes they randomly get shut off and you may not think to double check). Good luck!
@kathyhardy1387
7 жыл бұрын
How to fix a fault fuse link / field on a Legacy lrz pool & Spa heater?
@kathyhardy1387
7 жыл бұрын
Do you have any help for Legacy lrz heater that wont stay lit?
@Askthepoolguy
7 жыл бұрын
Sounds like something is telling the heater to shut down if it's the burners. Troubleshoot everything from the gas valve, to the ignitor, to cleaning out the internals, and even the filter pressure and air blower. www.zodiacpoolsystems.com/~/media/072f82733ed447a0bcab6afb9d4e1ef0.ashx
@MrBillybob57
5 жыл бұрын
Good information man but my raglan 266 propane reads ignition lockout. I shut everything off including the gas, bring everything back up and it fires off but goes off within 5 minutes and says the same thing. Could it be the gas pressure sensor ?
@raybridge7159
6 жыл бұрын
Hi, I have a Raypak P-D266A-EN-X pool heater. It will heat for about five minutes and then kick to the high limit and shut down for about three minutes then will start up again on it’s own. Any idea why this is happening? We have used this heater one season and just now starting up this season.
@MrBillybob57
5 жыл бұрын
Btw.. This is a commercial indoor pool and the heater is always on. It spots up almost monthly now and the burners look terrible.
@steveleahy1655
5 жыл бұрын
Any video on unblockng the pilot tubes? This seems to happen to mine a lot and someone needs to come out to service it. I haven't had the chance to be home when they do it, but I've wondered if it is something I can do myself.
@Askthepoolguy
5 жыл бұрын
Cleaning it with a pipe cleaner, steel wool or other tube cleaning tool may work.
@kimpolitsky5438
6 жыл бұрын
Mine randomly shuts off with a CFH code- thoughts?
@lindakramer6285
6 жыл бұрын
What about CFH constantly. Started this morning, then I vacuumed and got a lot of air into the lines. I assume you're not talking about water air. :)) SPK isn't even happening now. Mine is natural gas fed and has been working ok for a week after long winter.
@Askthepoolguy
5 жыл бұрын
If you have a lot of air in the lines or you aren't even getting a spark the flow indicator or pressure switch/pressure valve could be overriding the system and preventing the heater from trying to fire. Clean the flow, clean the filters, bleed air out of the lines with the filter air bleed setup and try again...
@FranksBmwAdv
6 жыл бұрын
good video , pay more attention to audio quality!
@Askthepoolguy
5 жыл бұрын
We're continuing to improve audio and video quality. Some of our videos were filmed on the original flip camera when it was the "best" easy to access technology. Our philosophy is still "if the content is worth it, post it, even if the video or audio have some issues"
@jeffhamula
6 жыл бұрын
I see rust below the burner tray. I have Extensive rust under the burner tray after only one season. Do you see this often and is it worth pulling out and painting with high temp rustoleum?
@michaelhart688
5 жыл бұрын
Me too. What's up?
@andynicky
4 жыл бұрын
My heater says sensor failure/sensor shorted. Do you have any suggestions? Thanks
@Askthepoolguy
4 жыл бұрын
Video Response: kzitem.info/news/bejne/um1_2nmuk2J0mmU
@Jaysonthomas128
7 жыл бұрын
I was wondering if you have ever come across this issue. Easy touch remote system activates raypak heater in rem on mode but it uses the raypak thermostat settings instead of the easy touch. Temperatures have to be changed in rem off and off course looked out in rem on but it won't let the easy touch control the temp. It even displays spa temp setting of the raypak heater in rem mode. I think the board is failing. Any thoughts??
@Askthepoolguy
7 жыл бұрын
It is sometimes complicated to get non Pentair equipment to play well with automation system. The auto mode should make the easyTouch panel control the heater, service mode should put the heater controls back in charge, however, they won't work unless the heat button is pressed on the panel. Pentair customer service (printed inside the easyTouch box) should also be able to troubleshoot with you...good luck!
@Jaysonthomas128
7 жыл бұрын
askthepoolguy thanks for the reply. It turns out it was the easy touch system. It wasn't closing the relay when it hit the set temperature.
@kcbr7048
7 жыл бұрын
how about if "spk" just stays on and it doesn't get past that
@Askthepoolguy
7 жыл бұрын
If it's just spk , Sounds like it's a gas issue. Is the Valve open? Or it could be a bad sparker.
@kcbr7048
7 жыл бұрын
gas valve is open. I am not sure what should be on the screen when it is working properly.
@franzapolski8863
4 жыл бұрын
Piolet lite lights but the burner will not light , changed piolet because the last piolet didn't light , ignition lock outcomes on piolet sensor.