Before switch on the apu bleed valve, run the apu for two full minute this is important
@hansloyalitat9774
2 жыл бұрын
no
@wazifiskandar1810
7 ай бұрын
Yes
@FlatOutMatt
5 ай бұрын
@@hansloyalitat9774if you care about it, you will
@damhaugandreas
3 жыл бұрын
whats the minimum battery volt before/ grnd/apu start? and can you do a complete startup, from you go on board and end with fmc?
@damhaugandreas
3 жыл бұрын
thank you ,but can you do a complete startup, ( apu gpu, and fmc)?
@SelvanSelvaraj
3 жыл бұрын
Thank You... Will surely do...
@spiritzm
3 жыл бұрын
Thank you, sir.
@Driver170
4 жыл бұрын
Hi, how noisy are the packs in the flightdeck
@SelvanSelvaraj
4 жыл бұрын
Yes.. unedited video...
@Driver170
4 жыл бұрын
Selvan Selvaraj are you able to do a video on the recirculation fans noise
@SelvanSelvaraj
4 жыл бұрын
Stuck in Lockdown...
@SelvanSelvaraj
4 жыл бұрын
But surely will do...
@Driver170
4 жыл бұрын
Selvan Selvaraj Stay safe
@pradeepnehra594
2 жыл бұрын
Sir can u plz explain pneumatics system
@fraserm803
3 жыл бұрын
Why fuel pump in tank 1 switched on after apu start?
@SelvanSelvaraj
3 жыл бұрын
Normally APU takes fuel from Left wing tank through Gravity Feed. There is no separate fuel pump for APU as in A320 aircraft. Gravity feed is through the fuel feed line (for engine#1) on LH Wing. So Fuel Pump of LH tank is normally kept ON to supply a Positive Fuel pressure though it is not really required.
@SelvanSelvaraj
3 жыл бұрын
Moreover the fuel boost pumps require AC power to operate which will be available after APU start..
@speedbird9313
2 жыл бұрын
@@SelvanSelvaraj APU takes fuel through gravity feed?! Are you serious??🙆🏻♂️😂
@SelvanSelvaraj
2 жыл бұрын
@@speedbird9313I might be wrong.. If you know please answer...
@speedbird9313
2 жыл бұрын
@@SelvanSelvaraj Gravity fuel feed requires the fuel to gravitate😉 Meaning the fuel tank must be above the apu.. If you dont use AC boost pumps to supply fuel (I dont) the APU DC boost pump will (automatically) supply fuel from the left main tank. If the AC and DC boost pumps do not supply fuel, the APU will suction feed from the left main tank.