We have a factory that requires 6 MVA electric power , Can we use one large transformer and limit the fault current with NGR? our transformer is 11/0.4 KV
@varadharajanelectricalengi5954
3 жыл бұрын
AWESOME EXPLANATION
@surendrakverma555
2 жыл бұрын
Very good. Thanks 🙏🙏🙏🙏
@ebrahimkhalil630
3 жыл бұрын
If NGR available is it require the metrosil
@srinikasamarakoon7924
4 жыл бұрын
Great explanation 👌
@prabhakarangovindaraj9238
4 жыл бұрын
Super sir keep it up 👏👏
@sriramprakash97
4 жыл бұрын
What will happen p1 and p2 direction are changed what is theory behind this direction changing
@007srv1
3 жыл бұрын
sir can you confirm the position of NCT and NGR in the circuit?
@trilochan9152
4 жыл бұрын
sir please make video of motor relay setting calculations video
@rukmagoud
4 жыл бұрын
sir what are the ratings of metrosil I. e current rating voltage rating power rating. In market how to order a metrosil
@electricaltechnologyandind5335
4 жыл бұрын
Good question. But i haven't found any thing related metrosil rating yet. If it is each relay maker indicates above which voltage their relay will require metrosil. So suppose you are using relay of a particular manufacturer. Then check their voltage limit for metrosil requirement like 3 kv or 2.5 kv. If the calculated voltage is higher than that, you have to ask for metrosil. And the manufacturer as per their standard design will provide the metrosil. However i will find further if i can get the standard ratings of metrosil....
@thinkseeeatthroughvickus4555
4 жыл бұрын
Plz do a video on relay burden calc - for both VT & PT
@electricaltechnologyandind5335
4 жыл бұрын
Pt and vt are same.. relay burden on ct will come in few days
@raselahmedtopu227
4 жыл бұрын
pls more for VC/SF6 control wiring with diagram
@vijaybabu8305
4 жыл бұрын
Why do we use stabilizing resistor????
@राज-च2छ
4 жыл бұрын
Sir 5 mva transformer ki protection scheme kya hoti hai?उस पर भी एक vedio बनायें।10 mva transformer की protection क्या है?
@electricaltechnologyandind5335
4 жыл бұрын
As shown in my video. Only trafo differential relay is mandatory which is not required for trafo less than 5 MVA.
@gourangbehura6791
4 жыл бұрын
Sir you have not explain.. How metro seal work.. When heavy voltage occurs
@electricaltechnologyandind5335
4 жыл бұрын
That will require another video..... This video is only for metrosil calculation
@himanshu2232
4 жыл бұрын
What is difference between restricted and unrestricted earth fault please elaborate it?
@electricaltechnologyandind5335
4 жыл бұрын
Please see my restricted earth fault philosophy video. Restricted earth faulr means the protection will work within a certain zone.
@ktsmurthy21
4 жыл бұрын
REF Relay will Operates , When Fault Occurred inside the Transformer Secondary winding , That is Called in zone. (Before Phase CT )
@sriramprakash97
4 жыл бұрын
Why NCT direction is changed i.e p2to p1
@ktsmurthy21
4 жыл бұрын
During Fault , Current Direction will flow to words Star Point. So Current Entry is P1.
@ktsmurthy21
4 жыл бұрын
In Phase CT side P1 &P2 and S1 & S2 to be reversed , otherwise Current will not nullify in normal Operation.
@electricaltechnologyandind5335
4 жыл бұрын
Can you give me reference? As per as i am concerned the ct terminals are given like that. And that is nomenclature only. Directional of primary and secondary current will be opposite. And under no circumstances the phase ct will give feed to relay as they are residually connected. So for a balanced suppy, (there could be negetive sequence current but no zero sequence or third harmonic current) the three ct will produce a net result of zero. Please watch my ct connec3for detection of earth fault video. You will have a clear idea.
@electricaltechnologyandind5335
4 жыл бұрын
If the both the terminals are reversed then it will not effect the result
@ktsmurthy21
4 жыл бұрын
I did REF testing Practically by Primary Current injection. Both Stable and unstable condition by Reversing CT Secondary terminals.
@electricaltechnologyandind5335
4 жыл бұрын
Could you Please share the circuit diagram at electricaltechnology04@gmail.com