Thank you nice explain and how much this h2s sensor
@anandarun326
Жыл бұрын
Txs bro
@vishnuvichu6758
2 жыл бұрын
Thanks for your information sir, Can you make one calibration video for Gastronic sensors
@theAestheticMariner
2 жыл бұрын
Sure it will come soon 🔜
@nepal_declassified
Ай бұрын
Where do you find H2 Span cylinders in india. Can you please provide vendor details.
@gunasekharpallala2605
2 жыл бұрын
Nice video brother can u make calibration video for itrans sensor
@theAestheticMariner
2 жыл бұрын
Yes sure I trans 2 sensor calibration video will come soon
@TamilBisayan
Жыл бұрын
Nice 🙏🏿... I would like to learn from your experience and knowledge regarding all fault errors... How to find out what the exact fault is and how to rectify it ... Can u help me
@theAestheticMariner
Жыл бұрын
Sure
@dayarao1555
Жыл бұрын
Can you post o2 calibration on xcd
@alanfate4853
Жыл бұрын
Which gas did you use? If I were to use 50% LEL methane (2.5%), should my PPM be 25000?
@theAestheticMariner
Жыл бұрын
Am using gulf cryo Gas for the Combustible Gas sensor using 50% LEL methane. Just change the sensor cell
@alanfate4853
Жыл бұрын
@@theAestheticMariner how do I do that?
@lordfizzz
Жыл бұрын
We set the XCD to 50% lel CH4 or 100ppm for CO. I use 2.5% (50% lel) also
@mohammedmujahid829
3 ай бұрын
Sir, I need wiring how to connect and start the device
@theAestheticMariner
3 ай бұрын
There is only 3 connections + ve -ve signal
@mohammedmujahid829
3 ай бұрын
Sir, your WhatsApp number..??
@theAestheticMariner
3 ай бұрын
@@mohammedmujahid829 +966553557811
@tony-10
Жыл бұрын
Are you using any mask or any safety equipment while calibration
@theAestheticMariner
Жыл бұрын
Yes am using n95 mask
@shameersharafudeen4530
Жыл бұрын
How to rectify communication error
@user-kc4lt7nt7x
Жыл бұрын
one of gms have some issue when going for zero calibration i found some value in zero calibration which not going to zero level .Do u have any solution about that
@theAestheticMariner
Жыл бұрын
Use the zero gas cylinder for the zero calibration
@sachidanandadhal9023
Жыл бұрын
@@theAestheticMariner it going to be -26 when I m going for zero calibration, I am using sensopoint xcd
@sachidanandadhal9023
Жыл бұрын
In zero calibration mode it showing - value when I applying gas it going to positive value but return to negative after tht
@sachidanandadhal9023
Жыл бұрын
Can u please elaborate the issue & the display showing fault alarm F-03
@Kannanvel78
Жыл бұрын
Can u pls help me after entering the menu up and down keys are not working
@theAestheticMariner
Жыл бұрын
Bro just remove the outer enclosure and try with magnet
@Kannanvel78
Жыл бұрын
@@theAestheticMariner yes bro i removed the cover . Enter button is working only up down key button not working
@theAestheticMariner
Жыл бұрын
Then you need to change the display unit bro. Try with big magnet