Dear sir, VFD se not only speed and smooth starting but torque bhi control kiya jata hai... In vector control mode.
@sarojkumarpradhan1917
10 ай бұрын
Sundar prachestha sir thanks
@kedarnathswain2540
5 ай бұрын
Sir squirel cage induction motor main resistance type stator q use karte hain,
@krishpatel2398
10 ай бұрын
Why is PT secondary never short-circuited????
@sujay3025
10 ай бұрын
What is cathodic protection system?
@gouraharisahu1583
10 ай бұрын
👍👍👍👍👍
@VivaanTiwariworld
Ай бұрын
But cant high starting torque be achieved by VFD's also nowadays?
@mehersb6561
10 ай бұрын
Great sir good information ❤❤🇵🇰🇮🇳
@Rakeshsharma-un2bg
5 ай бұрын
Sir grr and lrs ke bare me batey
@tejaskamble6738
10 ай бұрын
Please take lecture on Plc and plcs used in industries
@pramodsahoo1375
10 ай бұрын
Dear sir, in crane application during hoisting the rpm is low but lift full load. And during full load hanging condition the hoist run upwards without freefall. Plz explain
@sandeeprana3996
10 ай бұрын
Sir ht line ka fuse selection kaise krte hai iss pr ek video banana pls
@yadavkajalelectrical7312
5 ай бұрын
Sir yadi vfd ki life jyada old ho gayi hai aur vo 50 hz pe chal rhi hai to kya vfd ke jagah soft starter use kar sakte ??
@mariwala7608
10 ай бұрын
Good sir, MV VFD ki video banaye plz
@arvindnarake3574
4 ай бұрын
Nice
@rajendra138
10 ай бұрын
❤❤❤❤
@bernardlarsen8748
2 ай бұрын
Boiler ID fans having Slip ring motor planning to place vfd drive . What about your opinion?
@mirza4980
10 ай бұрын
Sir kindly explain why insulated bearing used in VFD drive motor?
@knbbrothers28199
10 ай бұрын
Sir G Yha sugar mill m slipring motor ko vfd se chalaya jata hai Ur vfd ke saat DBR use Kiya jata hai Please pura process btaye ki y kese hota hai❤
@pravintiwari8874
10 ай бұрын
High starting torque k liye bhi drive use hota hai sir
@cvrafeek
10 ай бұрын
Lift me konsa motor youse aathaahe
@samirmahato3907
5 ай бұрын
Why are used star delta
@dilipgore1332
10 ай бұрын
Can we start slipring motor on soft startor drive method
@km-kk5oz
10 ай бұрын
Line tester jab wooden table pe khade ho kar line test karte hai tab bhi kaise work karta hai ?
@AnilRathore9818
10 ай бұрын
Sir crane main konsi VFD work karti hai
@harjeetsingh-qy1dm
10 ай бұрын
132kV line used CTR 100/1 T/f 20MVA Normal current 56 amp Earth fault minimum and maximum settings......%
@uttamgajjar260
25 күн бұрын
Glr
@fazalurrehman7433
10 ай бұрын
But we have run a slip ring motor through a vfd after short its slipring side and it is working fine
@faizmuhammad7779
9 ай бұрын
Yes it will work fine. We can call it as induction motor. It will also provide High starting torque because we know condition for high starting torque..Rotor resistance should be equal to rotor reactance. R=Xl. Now let consider we have starting frequency from 5Hz, and inductance of coil is 1 Henry, Resistance of coil is 31.4 ohms. Reactance Xl = 2pi fL= 2*3.14*5*1= 31.4ohms. Here resistance will equal to reactance 31.4=31.4so it will provide high starting torque. So it will provide smooth starting and high torque....
@Abhishekpanwar001
10 ай бұрын
Sir please explain DG set GCB fail to close alram and explain your thoughts to help us and create video DG operation iam working on PCC department and I face these problems 🧑🔧@abhishek jhosi sir
@monal6305
10 ай бұрын
I think please check the closing ckt and UV relay or timer and their connections it's my opinion
Пікірлер: 35