its been an amazing 2022 team! Let me know what's been your favorite video down below!
@garybrown2039
Жыл бұрын
Hey man love your videos and thank you for making them. They really help me review when I am not working on the weekends but want to improve my knowledge. If you don't mind me asking is there a specific book you recommend for civil Fe engineers to study.
@muntahaabuhijleh329
Жыл бұрын
First, I would like to thank you for your great efforts, however I would like to see more critical cases like higher walls more than 30 feet. Many thanks again 🙌🙌🙌🙌🙌🙌🙌🙌
@Shehryk9
3 ай бұрын
My fav Structural Content Creator. Thanks!
@Kestava_Engineering
3 ай бұрын
thank you so much!
@lamtnguyen7083
10 ай бұрын
Hi, why didn't you use W_L and W_soil in calculating the resisting moment?
@jackyeh7512
Жыл бұрын
You might want to check if additional seismic load from the retained soil needs to be considered since the wall is quite high, at least in California.
@Kestava_Engineering
Жыл бұрын
yes very good point! I often have seismic load to account for up here in OR as well!
@kellytang5329
4 ай бұрын
why no passive earth pressure in resisting moment?
@hilmyzulfikar9243
Жыл бұрын
Hi, i would like to ask if seismic loads should be considered only for stability or also structural design? thank you
@goudhaantje3569
5 ай бұрын
Do you know any video with solutions when a 20 feet retaining wall is leaning (~5 degrees) ?
@FreekeeFang
Жыл бұрын
Would you be interested in helping with some retaining wall designs in Florida?
@himanshunegi3365
Жыл бұрын
Could you plz make videos over software design like Enercalc, shear wall excel and Staad.
@himanshunegi3365
Жыл бұрын
GREAT JOB BRO, CAN I HAVE YOUR CONTACT BRO, WANT TO LEARN FROM YOU.
@tmashadi
Жыл бұрын
Hello. Thanks for great video. Unrelated question for you about vertical cold joints. If I pour concrete retaining wall one section at a time leaving rebar sticking out to tie into the next section and keying the new wall into the old one, is it likely to leak and stop me from installing wall covering on top of the cold joint successfully? Is there a method to do this successfully? I appreciate any advice.
@Kestava_Engineering
Жыл бұрын
you'll definitely need to do extra detailing at the cold joists to ensure a water tight structure. there are products that can be cast into the joint and many other products that are for this exact situation.
@MartinAshmead
8 ай бұрын
Active soil depth should be measured down to the lowest level of the passive
@MartinAshmead
8 ай бұрын
Key depth.
@khurramali1975
Жыл бұрын
Please do video on tie back retaining wall
@stephenblasco8557
Жыл бұрын
Hey Kestava, any recommendations how to design a cantilevered retaining wall that retains water?
@Kestava_Engineering
Жыл бұрын
youll need to design for the additional hydrostatic pressure and you should look into additional ACI requirements for concrete structures in continuous contact with water. the concrete mix and detailing changes I believe off the top of my head.
@YonasBerhane-b5o
Жыл бұрын
At 3:46 why is equivalent fluid pressure 30psf?
@rezaahmadpour5402
7 ай бұрын
I think he should calculate the surcharge by multiplying 2' by 110 not 30!
@borisdjokaboris6424
Жыл бұрын
Hi, amazing channel. Hope that you'll do the external and internal design of this retaining wall in excel.
@Kestava_Engineering
Жыл бұрын
That's the plan!
@justv4487
Жыл бұрын
Can you explain, please, why you didn't take into account passive and active coefficients in the calculation of active and passive soil pressure? Cause in NBCC I see the formulas for finding this coefficient. Thank you, for your time and work)
@Kestava_Engineering
Жыл бұрын
Hi Just V - we were given the "equivalent fluid pressure" for our design this pressure already accounts for the active and passive coefficients. in the professional field it is common that the geotechnical engineer will provide these pressures in their geotechnical report so the structural engineer doesn't have to go through the process of calculating them.
@justv4487
Жыл бұрын
@@Kestava_Engineering Thank you for your reply! I asked this, cause in my practice, we really rarely have a geotechnical report. We design residential buildings and must calculate coefficients.
@prabasprabakar5632
Жыл бұрын
Can we design a cantilever retaining wall without heel slab height -7 m
@Kestava_Engineering
Жыл бұрын
good luck! I think your going to need to do sheet piles of some type...
@basilismail1179
Жыл бұрын
Hey Racz, Loved the video! Could you make a complete design tutorial for the flat slab as well?
@Kestava_Engineering
Жыл бұрын
After the retaining wall design is complete Im moving on to one way slab design and concrete beam design !