The "punchline" is at 5:30: oil failure is the only way to signal that the compressor's not running when one of the three legs of the contractor is out, right? But it sounds like the compressor started running again when the customer "hit" the reset switch on the pressure sensor. ? complicated, confusing. * * * Thanks for making. Am adding this one to the HVAC hall of fame playlist.
@hvacrjunky6119
6 ай бұрын
Thanks
@Mgear1217
4 жыл бұрын
Thank you for posting this video. It helped me what to look for oil failure problem.
@hvacrjunky6119
4 жыл бұрын
Glad it helped
@hg2.
2 жыл бұрын
Good nuance. Thanks for making.
@hvacrjunky6119
6 ай бұрын
Thanks for watching!!
@sjefoekel6058
4 жыл бұрын
Nice catch! That unit is in desperate need for a little love and care. Capacitor layin on the ground, leak at discharge line after vibration damper, condenser need straightning right fan, no thermal overload, fase loss prot.
@hvacrjunky6119
4 жыл бұрын
Yeah, it is one of those locations.
@hg2.
2 жыл бұрын
"Sharp eyes". - how can you tell there's a leak? Is it the oily discoloring to the left of the 'thingy' on the pipe (vibration damper?) - how can you tell the right fan needs straightening? - how an you tell there's no thermal overload? - what is fase loss prot?
@510DEACON
3 жыл бұрын
Big EZ,,,,, lol corona,,,,,, and that contractor just get out your pocket file and she's good for another year or two like catching your videos every now and again im chilling in Texas take care Brother
@hvacrjunky6119
3 жыл бұрын
What up The Butcher...lol. Good to hear from you. Yeah, I made these vids to hopefully help the guys coming up in the trade see the real refer life. There might be a day that I make my way to Texas too. Glad you're doing good, keep in touch.
@DWAYNE2ism
4 жыл бұрын
Great video with a lot of information
@hvacrjunky6119
4 жыл бұрын
Glad you enjoyed it
@AL3XW4R2
3 жыл бұрын
Now with a Johnson control oil safety to test it out. can just shut off the breaker directly to the compressor and allow the coil to energize the contactor and see if it breaks. Correct?
@hvacrjunky6119
3 жыл бұрын
Correct! That will initiate the control into timing mode and due to the compressor not running the net oil pressure will be zero and the control should time out and fail.
@goldhammer561
4 жыл бұрын
Awesome video Thanks for sharing Be safe from coronavirus
@hvacrjunky6119
4 жыл бұрын
Yeah, this CORONA stuff is crazy. I am good with the social distancing but some of the customers are acting like everything is normal and getting to close and touchy feely. Maybe I will loose a few pounds from avoiding fast food. Gotta look at the positive side. Stay healthy my friend.