This video is a 15-minute segment of an hour-long presentation presented by Todd Hatfield of HECO at the 2017 Reliability, Process, and Maintenance Symposium. This presentation discusses common preventable causes of electric motor failures. This section of the presentation discusses bearing related failures as bearings account for about 51% of all electric motor failures.
This presentation discusses bearing failures related to:
Insufficient lubrication
Too much lubrication
Mixing incompatible lubricants
Contamination
Electrical damage or fluting
Besides showing the issues, this presentation discusses what you may be able to do to help prevent these failures from occurring.