Very good information helpful and great advice excellent explanation valuable video thanks you God bless you sir jai hind 🇮🇳
@pramodverma8884
Жыл бұрын
Very practical knowledge, alot of thank
@RamanPrajapati-w5g
11 ай бұрын
Core cutter koi Girder 10-15 MTR height se fall huva hai to uska result correct mil sakta hai kya?
@saiprakashraju1253
3 жыл бұрын
what about steel inside, you take still also, so strength had came more....in cube at the time of concrete inside no steel, kindly explain.
@pankajkumarchauhan8236
Жыл бұрын
Arrow kaise draw kiye?
@rajatsingh2581
2 жыл бұрын
Core cut karne k baad sabse pehle Hume 48hrs k liye 24 to 30 degree temp pr water me dip karke rakhna padega phir iss procedure ko follow karenge kya sir
@ajay7148
11 ай бұрын
Sir RCC MEMBER SE cutting karte h usme steel bhi to hoti h plz explain kariye
@sportclub8529
3 жыл бұрын
you work great sir u great ................... love you from pakistan
@rbsinghcivilengineeringaca6777
3 жыл бұрын
Thank you brother 🙏🙏🙏
@deviddas9511
3 жыл бұрын
Sir, jaha se apne core cutting kiya woh toh ek important structure hein...toh core cutting krne ke bad jo hole ban gya usko kya karna sahie? Usko ese hi sor dia jaai ya fir var dia jai....var dia jaie toh uska process kya hein?
@rbsinghcivilengineeringaca6777
3 жыл бұрын
Dear jahan per ham log core cutting lete hain vahan per GP2 grouting material aata hai jisko use Karke usko feel Kiya jata hai, uski strength cement concrete ki Eastern se 2 guna hoti hai..
@deviddas9511
3 жыл бұрын
@@rbsinghcivilengineeringaca6777 Thnq you for the information 🙏sir, iss topic ko vi ek video banake smja dijie...toh sabke lie thik rhega... grouting material ka use kese kre...kaha kaha pe kre.. advantage disadvantage sab milake...
@ranjeetdas8230
4 ай бұрын
But isme Stirrups Cut nhi hota??
@sjc7108
2 жыл бұрын
Bhai ye test Kuch year baadme karege to jo purna cube ka result aaya thaa phir ohi aayega ya Kuch Kam jyada aayega Aur ye kitne saal ke andar kar sakte hai yaa kabhi bhi?
@rockyprasad817
3 жыл бұрын
Sir cube fail ho gaya hai core me kitna aana chihiye strength... Please help me
@AkashSharma-wd3zz
Жыл бұрын
Sir core cutting m strength 9 NM mil rhi h for m 25 concrete after 30 days for slab what should we do in this case please suggest.
@veersinghchaudhary927
Жыл бұрын
Sir prime coat and tack coat par video bnay full ditels me 🙏🙏🙏💖
@santoshnamdev1238
2 жыл бұрын
Sir yadi L/d ratio 2 se jyada aata h to us condition me kya correction factor use krte h
@nageshwaryadav6752
Жыл бұрын
Sir phese rete kitna rkhte h CTM ka
@SachinSharma-tv2dj
3 жыл бұрын
I have one doubt mr singh are we passing cylinder cube on comparing 28.28 with 35.48 i.e. cylinder strength and required strength respectively
@mukundkachhot8559
3 жыл бұрын
Great video sir
@rockyprasad817
3 жыл бұрын
Nice video sir..
@rockyprasad817
3 жыл бұрын
Sir Core ka dia kya liya jata hai.. Fix hai kya..
@pramodjadav7437
Ай бұрын
Thanks alot 👏👍🙏
@md.musharraf7950
3 жыл бұрын
Great post 👌
@AnuragYadav-hp2un
2 жыл бұрын
sir cement treated or lime trrated soil me kyu krte ha kab krte ha plzzz sir ye videoo banyee utube me koi aacha nhi ha plzzz sir sirr plzzz
@zulfiqarahmadmubarez
10 ай бұрын
Mr How to make graph of foctor and ration
@mukeshsharma7746
3 жыл бұрын
Very good video..
@hemantraturi3938
2 жыл бұрын
Where is dolly of core cutter test?? Kya wo dusra test h
@rakeshkumarbind5915
7 ай бұрын
Tcc concrete kyu karte hai site par
@souravmukherjee1992
3 жыл бұрын
Sir core 200mm depth me jayega.....to usme to steel rahega.....to hum 200 mm depth kaise jayenge
@rbsinghcivilengineeringaca6777
3 жыл бұрын
Concrete mein core lete samay Steel aata hi hai, but usse jyada koi fark Nahin padta hai, isiliye core lete samay as per Drawing Steel ka spacing check karna jaruri hai.. koshish karte hain jitna kam Steel aaye..
@rbsinghcivilengineeringaca6777
3 жыл бұрын
Lekin core lete samay is spacing jarur check karna hai Steel ka as per drawing taki core ke bich mein Steel Na aaye.. 👍👍
@ravishankarmishra3065
2 жыл бұрын
Very nice
@Akash24274
3 жыл бұрын
Very nice video
@sadanandpandey1
3 жыл бұрын
very good presentationj
@pranavnaxane2252
3 жыл бұрын
Great job
@jitendrashah205
2 жыл бұрын
Good.exlent.marvelous.
@ankitkumarrai6646
2 жыл бұрын
Nice video sir
@khanfahad93
3 жыл бұрын
Sir correction factor ki reading knha se li hi kaise?
@rajvernekar3515
6 ай бұрын
nice
@SushilKumar-mj6ch
3 жыл бұрын
Sir cc road me kitane Sqmt. me ek test hona chahiye
@navneetabhayrajput9929
3 жыл бұрын
Sir concrete to everyday strength gain karti hai or cube test 28 days mai hota hai to core cutter test kitne din baad karna chahiye
@rbsinghcivilengineeringaca6777
3 жыл бұрын
Casting karne ke 14 days ke bad hi..
@rbsinghcivilengineeringaca6777
3 жыл бұрын
Minimum no's of days -14 days , not Is code mention but generally 14 days ke bad hi Karna hai.
@SonuKumar-ej8im
3 жыл бұрын
👍👍👍👍 so nice sir
@mahadevchinchali2843
3 жыл бұрын
Excellent explanation
@AnuragYadav-hp2un
7 ай бұрын
28.23 KAHA SE AAYA SIR O TO 28.39 HOGA
@AliNawaz-nd5do
Жыл бұрын
Best
@desiteam100
3 жыл бұрын
Sir apka lab kaha hai.
@naveensrivastava8229
3 жыл бұрын
Sir ek video mai aap cylender ka lenght dia ka 3 guna bataye the aur isme 2 guna.,🤔
@rbsinghcivilengineeringaca6777
3 жыл бұрын
Dear 3D core cutting ke liye hota hai & 2 D testing ke liye..
@naveensrivastava8229
3 жыл бұрын
@@rbsinghcivilengineeringaca6777 thank u sir. 😊
@civilengineerknowledge6620
3 жыл бұрын
Good job sir
@rbsinghcivilengineeringaca6777
3 жыл бұрын
🙏🙏🙏
@khanfahad93
3 жыл бұрын
Bht bht shukriya sir 🥰🥰🥰🥰🥰
@Avineesh4RIDER
2 жыл бұрын
Core cutting ki frequency kya hoti hai
@vikaspradhan9425
6 ай бұрын
150 cum me 2 core cut karte h
@harendrathakur2104
2 жыл бұрын
🙏🙏
@visioncivil1143
3 жыл бұрын
Corrrction factor ko sir 1.08 se multipy ku nhi kiya
@rbsinghcivilengineeringaca6777
3 жыл бұрын
Dear correction factor 1 hai naki 1.08 , aur strength ke sath multiply kiya jata hai tab ja kar cylindrical strength aati hai.. uske bad ush strength ko cubical strength mein convert Kiya jata hai..
@visioncivil1143
3 жыл бұрын
@@rbsinghcivilengineeringaca6777 sir sp 24 1983 mai 1.08 se multiply kiya sir.dia less than 100mm or h/d ratio less than 2.0
@rbsinghcivilengineeringaca6777
3 жыл бұрын
@@visioncivil1143 Good morning dear , As per Sp24 - 1980 , yadi aapke pass graph table nahin hai to aap 100mm ki niche diameter ke sabhi core ko 1.08 ke correction factor se multiply karenge, lekin hamare pass already graph hai aur ham log as per IS code actual diameter of core hai & graph bhi available hai isliye actual correction factor nikalkar multiply karna.., aur yadi hamare pass graph & core ka actual diameter Nahin hota to 1.08 se multiply karte, ok dear very good 👍👍
@shubhamnarayankar4561
3 жыл бұрын
Incase core test me bhi fail hogaya toh means concrete ki strength nahi mili toh?
@rbsinghcivilengineeringaca6777
3 жыл бұрын
Required strength Nahi mil Rahi hai, is situation mein ek bar designer se consent karna chahie kyunki designer automatic 1.6 time extra lekar chalta, safe load.. aur yadi usmein bhi fail hota hai to fir concrete structure ko todna hi padega ya Fir extra jacketing kar sakte hain..
@shubhamnarayankar4561
3 жыл бұрын
@@rbsinghcivilengineeringaca6777 thank you sir
@anootalks4077
3 жыл бұрын
Sir as we already got strength of cylinder value in CTM machine as 29.56 then why we have to calculate again with load per area formulae.. pls tell? And why we have to compare cylinder strength with cube strength as we know concrete grade and ctm value of our core.
@rbsinghcivilengineeringaca6777
3 жыл бұрын
Already we have fitted the area of core in the CTM machine. How is it calculated? It has been told about this.
@anootalks4077
3 жыл бұрын
@@rbsinghcivilengineeringaca6777 sir we have fitted and core and obtained value reading directly then why again calculation?
@rbsinghcivilengineeringaca6777
3 жыл бұрын
Generally the strength of concrete is in cubicle shape, so the strength to comparison is done by converting cylindrical strength into cubicle shape, Already mention the formula in Is code..
@rbsinghcivilengineeringaca6777
3 жыл бұрын
only for explain the calculation.
@rbsinghcivilengineeringaca6777
3 жыл бұрын
Feed the core area in a digital CTM machine , So that direct strength show in CTM machine display.. ( N/mm2)
@Rashidiill
3 жыл бұрын
What if my core cut is low but rebound hammer is high?
@rbsinghcivilengineeringaca6777
3 жыл бұрын
There is no actual reading in the rebound hammer , Actually rebound hammer test results are + - 15 to 30 % fluctuate, So core test better than rebound hammer , And the strength of the core actually comes , Whereas the result of the rebound hammer test does not come actual.. So finally core cutter test better than rebound hammer test..
@Rashidiill
3 жыл бұрын
@@rbsinghcivilengineeringaca6777 but the problem is cutting core in beam or column is highly not recommended.
@Rashidiill
3 жыл бұрын
Do we have any other test who can give us clear results apart from ultrasound
@R_Ankit
3 жыл бұрын
Guru ji ko namaskar 🙏🙏
@rbsinghcivilengineeringaca6777
3 жыл бұрын
🙏🙏
@Blogcompany_New
3 жыл бұрын
Lekin DIA TO 94 se km nhi hona chahiye as per ASTM C42
@ramdevpaswan922
5 ай бұрын
Please explain graph 📈sir.
@anootalks4077
3 жыл бұрын
And plss explain how to measure thickness of various layers of road pavement.. how we will know at what time to stop core for each layer. For example if drlc layer is 200mm thick and above it 100mm pqc is there. Our core cutter length is 200mm and I want to measure drlc thickness whose bottom layer is 300mm below. How to measure?
@anootalks4077
3 жыл бұрын
Plss reply to this also
@rbsinghcivilengineeringaca6777
3 жыл бұрын
The minimum core diameter is usually 100 mm but 75 mm and 50mm diameters may be used in special cases, Already core mould available in Quality lab..
@rbsinghcivilengineeringaca6777
3 жыл бұрын
We should do the layer wise test and the result is satisfactory after that allow the next layer..
@rbsinghcivilengineeringaca6777
3 жыл бұрын
DLC - Dry lean concrete, This is a cement concrete with low slump value to be laid for rigid pavement over sub-base and rolled & compacted by mechanical roller , capacity of roller 08 to 10 ton with vibro roller, With compaction not less than 97% as per morth guideline.
@rbsinghcivilengineeringaca6777
3 жыл бұрын
concrete core cutting test and compaction core testing both are difference test method..
@jayshreeconstruction1986
3 жыл бұрын
👍
@dr.akashmohanty5638
2 жыл бұрын
Excellent
@rajneeshsharma70
2 жыл бұрын
Thank You, Sir
@sankartavar1867
3 жыл бұрын
Very good
@rockyprasad817
3 жыл бұрын
👌 👌
@sumanvishwakarma4407
3 жыл бұрын
👌👌👌
@AnandKumar-jg5cg
3 жыл бұрын
Sir ji core cutting test ka formate chahiye sir plz
@rbsinghcivilengineeringaca6777
3 жыл бұрын
Ok Please send the mail id
@sushmasarpane898
3 жыл бұрын
Me ,too Sir send the format of test to ynb.nbnscoe@gmail.com Wating for you response Thank u ...