Setting up your inverter and battery for optimal depth of discharge and SOC cut off. And force charge to prevent batteries going completely flat.
Overdischg SOC
ForceCharge SOC
For Ref: (DoD = Depth of Discharge)
Pylontech US2000B - 80% DoD for 6000 cycles or 90% DoD for 4500 cycles lifespan
Pylontech US2000C - 95% DoD
Pylontech US3000 - 90% DoD
Pylontech US3000C - 95% DoD
Pylontech US5000 - 95% DoD
Pylontech US5000B - 95% DoD
Fox LV5200 - 90% DoD
RHI-3K-48ES-5G RHI-3.6K-48ES-5G RHI-4.6K-48ES-5G RHI-5K-48ES-5G RHI-6K-48ES-5G
S5-EH1P3K-L S5-EH1P3.6K-L S5-EH1P4.6K-L S5-EH1P5K-L S5-EH1P6K-L