Output Power: The following are guaranteed minimums for standard 1-kHz power from 120 VAC, 60 Hz North American units. Maximum average watts per channel (unless in Mono mode) at 1 kHz with 0.1% or less THD.
Stereo mode with both channels driven:
1800 watts into 2 ohms
1565 watts into 4 ohms
1120 watts into 8 ohms
Bridge-Mono mode:
3505 watts into 4 ohms
3140 watts into 8 ohms
Parallel-Mono mode:
3555 watts into 1 ohm
3190 watts into 2 ohms
Load Impedance: Rated for 16, 8, 4, and 2 ohm use only. Safe with all types of loads, even reactive ones
AC Power Requirements: 100 VAC, 50/60 Hz; 120 VAC, 50/60 Hz; and 230 VAC, 50/60 Hz units are available. 230 VAC, 50/60 Hz units can be used with 220 and 240 VAC. All versions draw 90 watts or less at idle. 100 and 120 VAC units can draw up to 30 amps of current; 230 VAC units can draw up to 15 amps.
Performance
Frequency Response: 0.1 dB from 20 Hz to 20 kHz at 1 watt.
Phase Response: 10 from 10 Hz to 20 kHz at 1 watt.
Signal-to-Noise Ratio: Greater than 105 dB below rated output (20 Hz to 20 kHz, A-weighted); 100 dB below rated output (20 Hz to 20 kHz, no weighting).
Harmonic Distortion (THD): At rated output, less than 0.05% from 20 Hz to 1 kHz increasing linearly to less than 0.1% at 20 kHz.
IM Distortion (IMD): Less than 0.05% from 368 milliwatts to full rated output.
Damping Factor: Greater than 1,000 from 10 Hz to 400 Hz.
Slew Rate: Greater than 30 volts per microsecond.
Voltage Gain: (At maximum output) 20:1 6% or 26 dB 0.25 dB at +26 dB gain setting, and 124.6:1 6% or 41.9 dB 1.0 dB at 0.775 volt sensitivity.