CURTIS PC programmer 1314-4402: www.noco-evco.com/product/131...
CURTIS handheld programmer 1313-4331: www.noco-evco.com/product/131...
CURTIS controller 1268-5403: www.noco-evco.com/product/126...
CURTIS controller assemblage: www.noco-evco.com/product/126...
With the CURTIS PC Station Programmer 1314-4402 with 1309 USB Interface Box, we can easily diagnose a CURTIS programmable controller, identify its fault or failure cause.
For the 1268 DC SepEx controllers, a safety function "Walkaway" is provided (optional by setting the controller parameter "AUX DRVR MODE" as 1). The WalkAway function applies field current to slow a vehicle that is detected as moving while the main contactor is open. The motor force created from this function is intended to limit the vehicle’s rolling speed, but may not be sufficient to slow heavy vehicles on steep slopes. The warning buzzer is pulsed to create an audible indication that the vehicle is rolling.
When the Walkaway function is selected, a fault code 5,4 (CIRCUIT BRKR OPEN) is often noticed by the user. In this video, we present how this fault code could be removed.
Негізгі бет Автокөліктер мен көлік құралдары CURTIS DC SepEx Controller 1268-5403 Diagnostics
Пікірлер: 41