Brother you can go 00-02 setting ,set.default Factory reset for 50 Hz motor ,enter 9 for 50Hz,10 for 60 Hz motor
@ashaq143
5 ай бұрын
Please tell me do we need to enter any new parameters after resetting the vfd. We are using them in Milk packing machine
@Sakthivel-om7ss
Жыл бұрын
இந்த டிரைவை பயன்படுத்தி 2 பேஸ் இபி லைன் ஐ 3 பேசாத மாற்றமுடியுமா
@valsonvasanth9233
Жыл бұрын
பண்ணமுடியாது, ஆனால் 5 hp drive la 2 hp 2 phase la run agum,otherwise 2 phase to 3 phase choke type transforme in input side
@valsonvasanth9233
Жыл бұрын
Special edition VFD available contact delta supplier
@Jayarajkanna
19 күн бұрын
Enna price sir?
@valsonvasanth9233
14 күн бұрын
You want VFD?
@Ragavenutb
6 ай бұрын
Sir, Cd1 error varuthu as soon as on, no load connected..
@valsonvasanth9233
6 ай бұрын
Brother cd 1 u phase current CT sense ஆகவில்லை (internal problem) Factory reset,dust and moisture clean(wd40 spray use,power off condition) இது மட்டும் பண்ணி பாருங்க, Current Transformer terminal moisture la short ஆனாலும் sense ஆகாது ,இதுல சரி ஆகவில்லை என்றால் service தான் (authorised service person) possible
@Ragavenutb
6 ай бұрын
@@valsonvasanth9233 Thank you sir, but second board (capacitors) yeppadi remove panrathu, theres no screw or lock holding but its very hard to pull out to access CT & igbt board..
@rajv6907
Жыл бұрын
Voice over noise 😡😡😡
@valsonvasanth9233
Жыл бұрын
புதுசா முயற்சி பண்ணியது plant near by running, அடுத்த முறை சரி பண்ணுறேன்
Пікірлер: 21