Special requirements in mechanical seals occur in the operation of sterile processes, such as food processing, in the pharmaceutical industry and in biotechnology. Therefore EKATO offers a complete sterile system consisting of a mechanical seal and a sterile installation. The EKATO sterile system is used when the vessel/process shall be sealed from any germs and microbes by the mechanical seal.
More Info: www.ekato.com/...
The EKATO sterile system is an ideal solution for the process demand of a hot and completely sterile seal liquid where germs and microbes cannot grow. On the other hand to serve the mechanical seal demand of cool seal liquid for seal face lubrication and cooling.
The operation of the sterile systems occurs in 3 steps:
Step 1: Flow-through sterilization
• The agitator remains in standstill
• Cleaning and sterilization of all parts with fresh steam
• No cooling by the heat exchanger
Step 2: System-filling
• The agitator remains in standstill
• Filling the system with sterile condensate
• Condensation by the heat exchanger
Step 3: Continuous loop-operation
• The agitator can be started
• Cyclical sterilization of the condensate by fresh steam
• Cooling of the seal liquid condensate by the heat exchanger
• Constant system filling level due to a steam trap at the storage vessel
• Overpressurized system due to steam pressure
• Seal liquid condensate with ideal operating temperature for extended seal lifetime
Негізгі бет EKATO Sterile System - for mechanical seals