I heard that if your static is no good its going to affect your furnace gas setting ( regarding this ULN furnaces
@davidfreeman2316
3 жыл бұрын
You ARE worthy.
@bmkolb
3 жыл бұрын
I don’t like using a combustion Analyzer to measure gas pressure. Should use to separate tools. And you should check Gas Pressure at High and low fire to make sure gas regulator is operating correctly.
@NighthawkHVAC
3 жыл бұрын
Agreed. Using the built in manometer adds the reading to the reported by the Analyzer. This unit uses a modulating gas valve. Adjusting this gas valve only adjusts the gas pressure range. Thanks for the feedback and thanks for watching.
@albertoandrade1457
4 жыл бұрын
Good job !!!
@martinlutherkingjr.5582
20 күн бұрын
Does an Ultra Low NoX Furnace result in any better *indoor* air quality than a 30 year old natural gas furnace if both are properly vented?
@TechnicalLee
4 жыл бұрын
What a strange looking and sounding furnace. I was waiting for you to say "This concludes the test of the Emergency Broadcast System"...
@NighthawkHVAC
4 жыл бұрын
That it is! Its a new type of furnace that is now required in Socal, Its a Ultra Low NoX Furnace. Thanks SCAQMD!
@cruzrobledo6631
2 жыл бұрын
Well explained Thank you!
@iwatchstuff7265
4 жыл бұрын
Before you start your video, you should start it with an intro with you yelling "Wes! Side!" With your fingers twisted. Trust me you get more views.
@buffordbaxter3370
4 жыл бұрын
I’m a big fan of the SL280
@NighthawkHVAC
4 жыл бұрын
Are you being sarcastic? I like them till they run in second stage. Lol
@buffordbaxter3370
4 жыл бұрын
Nighthawk HVAC no, I’m not being sarcastic.
@markdrummond5946
4 жыл бұрын
Great Job Nighthawk
@greekmaster1001
8 ай бұрын
Any links to the test port adapters? Where do you get them from?
I am on the verge of buying a 310, I just dont like the idea of having to send it back every couple years for sensor replacement and recalibration.
@NighthawkHVAC
3 жыл бұрын
It’s a bummer but it’s just part of the territory with digital equipment. I get my Testo 550 refrigerant gauges calibrated every year. I think you can replace the sensors yourself. Not sure though.
@alexsierra2
4 жыл бұрын
What is Lennox doing about those loud and vibrating inducer motors Wes ? Do you know ?
@NighthawkHVAC
4 жыл бұрын
They’re super quite in first stage heat. But once it goes in second stage forget about it. One thing that seems to help a bit is extending the air in-tank with a 90 degree about 2 feet with 2” PVC. This dampens the sound of air rushing into the burner plenum. But you have to make a 3” hole in the side of the furnace. This is really difficult with the A cabinet due to it being so compact. But helps some.
@jasongill9407
3 жыл бұрын
Since they create condensation, shouldn't the flue be pvc?
@NighthawkHVAC
3 жыл бұрын
Only the 90+ ultra low Nox furnaces produce condensation. This was the 80+ version of the ultra low Nox furnace. The condensate trap in the analyzer is used when testing 90+ furnaces.