Many thanks for the excellent info. My flexicom had the F9 and the startup did the four noises but no pump. Apparently it always runs the pump on startup just to make sure it is working. Took the pump motor from another flexicom and plugged it into the circuit board. This one did whirr on startup so it was the pump. Changing the pump was not too difficult. You have to drop the accessory housing out of the bottom of the boiler housing then you remove the four allen key bolts. You need to drain the boiler as much as possible as water spurts out when you loosen these bolts so a bucket will have to be put under the boiler to collect this. The replacement pump motor with its impeller (these seem to be available new on ebay) is then bolted back onto the pump and the cable plugged into the PCB. A bit of a thorough dry all round and a refilling then the boiler worked perfectly. Without Dave I wouldn't have had the clue that it was the pump. A really helpful video. Thanks.
@DaveLane1964
5 жыл бұрын
HI Andrew great glad I helped you fix it.Dave
@kimlafferty3672
7 жыл бұрын
Thank you, Dave, this saved my life!! Got home late last night to a freezing cold house. Discovered the F9 fault and while searching found you. Managed to get the pressure up and now have a lovely warm house again. Many thanks for sharing your expertise :)
@joemak100
5 жыл бұрын
Thankyou Dave...My boiler is working again...pressure sensor was stuck...increased pressure only from 1.5bar to 1.6bar and boiler came back to life. Thumbs up from me mate.
@moirbarbie
2 жыл бұрын
Thankyou i needed this to keep my boiler going til engineer comes out .Your a lifesaver
@jeannettebass-cooper9682
2 жыл бұрын
Thank you so much - we just had a quote for nearly £600 - boiler fixed for nothing! What an amazing service posting this information.
@Poet1968
2 жыл бұрын
Absolute legend! I had a SMART meter installed today and after the engineer left and I turned the boiler on it was showing F9 code. I planned to call the service company tomorrow and feared a big bill...but then I came across this video and it worked. Boiler working and hot water back on. Thanks so much Dave ☺️
@dawnfeatherstone4838
6 жыл бұрын
Phew!! Thick snow and ‘feels like’ temperatures of -10 here in Norfolk today, and I wake up to a freezing house and ‘F9’ flashing on my boiler. Thank goodness for this tutorial...probably saved me a fortune in call out charges 😳 House now warming up nicely, thanks Dave!!
@g20gasservices
6 жыл бұрын
Thanks Dawn glad it helped x
@ministertoddington8928
2 жыл бұрын
Thank you very much Dave. The boiler has restarted! so grateful for the guidance.
@loucalouca
2 жыл бұрын
Awesome video , it wasn’t the flow pressure switch but turned out to be the pump like you said ! Got the new one , at first it seems like you have to change the whole housing as the bolt thickness is completely different , but you can screw the OLD bolts through the new pump holes ! Happy days thank you 🙏😁
@tim0steele
3 жыл бұрын
Great video, thank you for making it. Turned out to be the pump, unplugged it and checked the resistance, it was open circuit. Glow worm now supply a new Grundfos pump which replaces the old Wilo pump. Heads not the same so had to replace the whole thing.
@ianmcgregor5861
3 жыл бұрын
Thanks Dave. Had continual F9 faults in the morning with my Ultracom 30 Xsi and getting more regular. Could start using your fix by adding some water. Got the BG boiler engineer who said the expansion vessel was the issue which he recharged. He also did the annual service which was long overdue to Covid. Next morning F9 again. Was reluctant to start messing about with the boiler even though I am an engineer but decided to pull the pressure sensor. As you suggested it was clogged solid with gunk. Cleaned it out, reinstalled and F9 faults no more. Thanks. If clogged pressure sensors on these boilers are such an issue why don't they inspect them as part of the annual inspections as you do?
@marydone7826
3 жыл бұрын
Dear Dave, Christmas morning and an F9 fault! Followed your instructions and the Glowworm combiner's is now working! Fantastic! And thanks!
@g20gasservices
3 жыл бұрын
Great glad it worked. Happy Xmas
@lesleycoleiro9346
4 жыл бұрын
Thank you so much! I would have had to wait 10 days for the council to come twiddle those grey knobs!
@stephenhowarth4059
4 жыл бұрын
Brilliant advice.. followed info.. really easy.. Boiler working fine.. Thank you so much... Steve aged 71
@mikekeegan1652
5 жыл бұрын
Boiler playing up today (Christmas Eve Eve of all times !) and Dave's first tip overcame the problem. Dave, you saved Christmas ! Thanks ! Mike.
@DaveLane1964
5 жыл бұрын
great glad it worked. Have a great warm xmas
@adrianbroadbent7666
4 жыл бұрын
Thanks very much for the clear and concise instructions, this fixed my F9 issue but I’ll call out an engineer to give it a service, it was only done in Feb 20 as well!
@rikochetuk
6 жыл бұрын
Dave, a huge thank you for the advice. Your pressure increase tip worked first time and the boiler is now working as per normal. Even more appreciated as it's Easter Sunday and the call-outs would have been even more pricey!
@g20gasservices
6 жыл бұрын
Ricky Kaup glad it helped 👍🏾
@snacksonaplane
3 жыл бұрын
Thank you David. Excellent advice. Much appreciated. I saw the F9 this morning and until I saw your video I was worried. Turning the taps until it went from 0.6 to around 1.2 worked a treat. Maybe I have to bleed the radiators but for now, I've got the hot water back. Cheers.
@halochamppp
3 жыл бұрын
I've done all this and it works... the hot water that it, as soon as I turn on the heating then that's when the F9 fault appears. Time to call a professional before winter hits?
@K5aty1
8 жыл бұрын
Thanks very much! Glow worm wanted me to rebuild my boiler, home insurance wanted to charge an excess on emergency cover and local gas fella wanted ££££ to come a look at it. Your video sorted it right out. Thanks very much.
@DaveLane1964
8 жыл бұрын
Glad it helped 😀
@alisajanmohamed7158
8 жыл бұрын
Thanks so so much Dave! Just got back from holiday- around 2:15am and we had no hot water and all we were looking forward to was having a hot shower after all our travelling. With your help we manager to get out hot water going! Big thank you!
@sylkajoseph8117
2 жыл бұрын
Dave doing God’s work
@SuperStrutt
2 жыл бұрын
God I love KZitem Thanks for your help 👍🏻
@mickwilkinson8046
5 жыл бұрын
Big shout out and thumbs up! Your videos saved me a fortune in engineers fees and enabled me to better understand and fix my flexicom. Pressure sensor tip was epic
@shehryarmirza5165
5 жыл бұрын
Did exactly how Dave explained it... its working! Thanks mate
@rebeccalouisegaskell5910
2 жыл бұрын
Amazing, saved my night. Was stressing so much and the first video I found was this one. My flat is now warm thank you Dave 👌
@kaseryn
2 жыл бұрын
Worked for me thanks.. didnt know about the easy top up knobs.
@suecorrigan8269
Жыл бұрын
Thanks Dave. I refer to this every time I have an F9 because I always forget what I should do. Boiler working again now. 😊
@ChrissyPeeks
3 жыл бұрын
This is so useful thank you!! Got my boiler working on Xmas day (such a relief!) but now everyday I need twiddle the taps every morning to get it going 😞
@g20gasservices
3 жыл бұрын
Hi check for air in your radiators if there isn’t loads of air and it’s still giving problems then arrange a boiler service but tell him you want the pressure sensor changing and the expansion vessel checking. Refer him to my video. Dave
@ChrissyPeeks
3 жыл бұрын
@@g20gasservices will do! Thank you so so much. Honestly you saved my Xmas day 🥰
@karenbarney4818
4 жыл бұрын
Thankyou dave got home from holibobs . Your clear instructions did the trick .
@DaveLane1964
4 жыл бұрын
Great glad it worked👍
@duncanb6354
3 жыл бұрын
I used to have loads of problems with F9 sensors on a Flexicom SX30. Many pressure sensors replaced but eventually found that from the first installation - the boiler internal expansion vessel had been over-pressurised. With the boiler main system depressurised, the expansion was at 1.8 Bar. The manual says it should be 0.5 Bar. Once reset to 0.5 Bar, I have never had another F9 fault. This was not a combi boiler, just a system boiler.
@krzysztofluszczynski9826
2 жыл бұрын
Legend, all going now. Thanks man
@marydone7826
3 жыл бұрын
What with all the excitement, I forgot to wish you a Happy Christmas! Have a good one!
@ossital1808
2 жыл бұрын
Thanks Dave for sharing
@ms12textiletime
2 жыл бұрын
Thank you so much.. Your video has really helped me today, am very grateful.
@iainh8639
4 жыл бұрын
What an amazing video, Dave. Worked first time so cancelled the emergency call I’d just booked Homeserve. Thank you!
@g20gasservices
4 жыл бұрын
Iain H great glad it worked
@mervegursoy8417
6 жыл бұрын
Thank you! Very clear instructions and solved the problem immediately.
@tomlipfriend17
4 жыл бұрын
Absolute hero, thank you so much it worked great. F9 flashing at 1.4bar raised to 1.8 and started working fine. Bled all the radiators and was some air in them so worth doing. Now at 1.5 bar and heating and hot water working!! We tried to call 3 plumbers who gave us a weeks call out as they were so busy. Thank you for making this video as was simple to fix even for a novice! Cheers!
@g20gasservices
4 жыл бұрын
Glad it worked 👍
@christopherscales3373
3 жыл бұрын
Absolute 24ct legend Dave 🙌! Thanks so much for the clear, concise, excellent and very generous information. Many many thanks mate.
@MrNickJacobs
7 жыл бұрын
Thanks for this Dave, New Years Eve and my heating goes! You saved me from passing the new year in shivering in my coat. The first solution you offered fixed it for me. Thanks again.
@DaveLane1964
7 жыл бұрын
Fantastic glad it worked for you it wouldn't have been a very good nye otherwise. All the best. Dave
@shaunmeht3955
3 жыл бұрын
Thank you Dave, saved me a few Bob
@carlosthegerbil
6 жыл бұрын
Dave, you are a superstar, thanks very kindly for this. Saved me from a cold shower in the morning.
@frankystephenson2323
3 жыл бұрын
Thank you, sterling advice and avian companion.
@makani8787
4 жыл бұрын
Great informative video... I managed to follow all your instructions and got my boiler sorted this mornin... Many thanks!
@MrDazTroyer
3 жыл бұрын
Brilliant, thank you. Got it going and an engineer is on route. Cheers
@martinwinterburn2391
4 жыл бұрын
Thanks a lot Dave just watched the video had the f9 fault, it worked first time
@leehollywood01
6 жыл бұрын
Super stuff mate. Saved me an expensive emergency call out fee. Thanks a million.
@g20gasservices
6 жыл бұрын
leehollywood01 great glad it helped
@elizabethreveley9111
7 жыл бұрын
Thanks Dave, saved me £100 call out fee and managed to get it working with the first suggestion!
@xyz212123456
3 жыл бұрын
Worked thanks Dave, this is working in 2020 lockdown 2.0
@artengit
5 жыл бұрын
Great video, the re-pressurising has worked on my boiler sx18 a few times in the last 5 years. When that failed I find just wiggling the flow sensor connector has helped. Today I found that wasn't enough and had to fix the connector by squeezing the pins together. As an electrician I have often found simple problems are due to poor connections, the connector on the flow switch is a cheap edge connector onto the circuit board edge of the flow switch. Any work to remove and clean or replace the switch may mask a simple issue with this connector that could present as an intermittent fault.
@g20gasservices
5 жыл бұрын
Andrew Benjamin thanks for that it’s food for thought! I’ve got a couple of customers that have had their boiler replaced by glow worm because of this intermittent fault! Cheers
@artengit
5 жыл бұрын
@@g20gasservices It is quite easy to pop the connector apart and squeeze the pins together with needle pliers and it grips much better when refitted.
@g20gasservices
5 жыл бұрын
Andrew Benjamin thanks for that. Is it two clips on the side? I’ve not got my glasses on!!😂
@gregtbomas1715
4 жыл бұрын
Thanks Dave. Away from home and you just made that very simple for the wife 👍
@g20gasservices
4 жыл бұрын
Greg Tbomas glad it helped
@gillianthomas1459
6 жыл бұрын
Hi Dave - I LOVE YOU !! - Shh - don't tell Debbie! - You're a hero and have reduced my stress levels 100%. I can now have a bath!! xx
@g20gasservices
6 жыл бұрын
Gillian Thomas haha ok mums the word!! Glad it helped xx
@theopendoorchristianfellow7687
Жыл бұрын
Hi Dave. Our Church Manse boiler (Flexicom Glo-Worm) is showing the F09 fault even when the pressure is at 1.4bar. Is there a way to adjust the point at which it faults?
@danielbennett2891
5 жыл бұрын
You, my new friend are amazing. Freezing cold house and now the boiler works!
@g20gasservices
5 жыл бұрын
Cheers Dan glad it worked
@mandyfitzmaurice751
5 жыл бұрын
Great help, so helpful, followed your instructions and it worked, hot water and warmth restored, many thanks.
@g20gasservices
5 жыл бұрын
MANDY FITZMAURICE glad it helped
@robhills2398
4 жыл бұрын
Hi Dave, I have a similar fault with F9 showing on my ultracom cxi. The pipe to the left of the boiler with a rubber hose attached developed a small leak, I removed this and found the pipe had a blockage, full of large rusty particles, I cleaned the pipe out, removed the pressure sensor and cleaned it took the pump head off for a check and was clean inside and pump vanes manually free to rotate by hand. On startup, I can hear the diverter valve working, but the pump doesn't startup or make any kind of start-up noise. Pressure reading 1.5 bar. Is the pressure displayed a reading from the pressure sensor that is causing the F9 fault or is read from another sensor? What are your thoughts on this? is it a faulty pressure valve or pump? I tested the pump head with it dismantled from the pump housing and hit the reset to see it would startup, nothing happened! Hoping you can point me in the right direction.
@g20gasservices
4 жыл бұрын
Hi Rob if the boiler was drained down then the display should have said 0.0 bar or close to it. If the pressure is under 0.5bar then the boiler or the pump won’t work!. Once the pressure is above 0.5 bar then the pump should spin. It’s tricky to test the pump but if you’re comfortable with electrics you could push a live and neutral in the pump plug! Is the pump a Wilo pump? If so they are a bit dodgy! Dave
@robhills2398
4 жыл бұрын
@@g20gasservices thanks for the reply Dave, when you say push live and neutral in the pump plug what does that mean? I did notice that maybe there was broken connection at the pump as when I moved the wire sometimes the pump would start up, but then slowly cut out again, I thought this was a coincidence? It is a silo pump. Could there be a fault with the pump wiring?
@g20gasservices
4 жыл бұрын
Hi Rob it’s usually the red switch on the boiler that goes faulty. If you mess with it the pump might start but it won’t last! You’ll need a new pump. Unfortunately they don’t supply Wilo pumps anymore so you’ll have to fit a Grundfoss but it comes with the housing as well so it’s a bigger job than just changing the pump head!
@robhills2398
4 жыл бұрын
@@g20gasservices okay thanks fella, pump is working, just a very silent pump, going to clean out the plate to plate exchanger. The display is now only reading the water pressure, as I set it and the boiler seems to be stuck there even after many resets.
@tonywilliam9438
7 жыл бұрын
God bless you Dave
@ernestkarumazondo8654
4 жыл бұрын
Thank you
@Arkvilla
7 жыл бұрын
So grateful to you for making this video, it cleared my fault straight away. I'd read my user guide and oculdn't find anything so when I found your video it was a God send
@DaveLane1964
7 жыл бұрын
Arkvilla, Vacation Rental near Disney World, Florida glad it helped. Dave
@Gregrum1981
2 жыл бұрын
You are a legend. Thanks. Pressure top up worked a treat.
@thebigredone4230
4 жыл бұрын
Hi Dave a customer is having the same problem cleaned everything out checked pressure vessel done every thing an F9 fault relates to, screen now gos blank and flashers with fault on reset I can only think it is the PCB? you comments please
@g20gasservices
4 жыл бұрын
The big red one what does the fault say on reset? Is it a flexicom? Dave
@thebigredone4230
4 жыл бұрын
@@g20gasservices Ultracom sxi always shows f9 its intermittent runs for an hour then gos to fault
@garrymetcalfe5689
5 жыл бұрын
thanks dave fitted pressure sensor today all working now, i had a problem fitting in new part so i swapped the rubber seal and went in easy, please advise me which grease to use and do you put it in the small hole,
@g20gasservices
5 жыл бұрын
Hi Garry I use silicone grease
@sophieyoung1411
6 жыл бұрын
Thank you Chicken man. I don't know what I did but now my boiler works. Hurray! Thank you
@MrWOBBERZ
6 жыл бұрын
Nice one Dave . Top man. Boiler gone from 'bobbins' to 'mint'. Thanks for the info.
@g20gasservices
6 жыл бұрын
MrWOBBERZ great glad it worked 😀
@ruinunes8251
4 жыл бұрын
I have a Glow worm flexicon 24CX, the display is the same as the one in your video, and when we use the heating, for some reason the pressure showing in the display keeps going up and up slowly and never decreases. within a week, as we use the heating, the pressure showing in the display goes up to 2.7 bars. I then need to use one of the drain off valves in one of the radiators and drain some water in order to bring the pressure down to 1.0-1.2 bars. What is causing this? I'm monitoring this situation and when using just hot water in any of the taps, it doesn't make the pressure to go up and up like when using the heating.
@g20gasservices
4 жыл бұрын
Rui Nunes hi inside the boiler is an expansion tank which takes up the expansion of the central heating water when it gets hot. This tank should be pressured with air however if the air leaks out or if the tank is punctured then the pressure will increase when the heating is on. You need to book an engineer when we’re out of lock down. Regards Dave
@thestamsvideoproduction7427
2 жыл бұрын
Can't believe it but you fixed the issue! Thank you!
@smadlani
7 жыл бұрын
Dave You are very clear and well explained for anyone to understand and being technical person I can understand the logic behind the steps explained by you.
@DaveLane1964
7 жыл бұрын
Subhash Madlani thanks appreciate your comments. Dave
@Nikkro
4 жыл бұрын
Absolute legend, this sorted the problem !
@TheRapidprh
8 жыл бұрын
Hey Dave I have a glow worm flexi com 24cx I have a timer fitted to the boiler but no thermostat. My radiators have the thermostat valves on but I would like to fit a room thermostat. Is it possible to fit a room thermostat to this boiler model and if so which one would you recommend? Many thanks Peter
@g20gasservices
8 жыл бұрын
Hi Peter yes you can connect a thermostat to your flexicom. You can use either a wired or a wireless. The tricky thing is removing the wiring plug that goes into the boiler! Follow the wire that goes in the boiler on the left hand side and remove the 2 screws that have a torx head on them! This will allow the black plug to be pulled out downwards. Inside the plug are the wiring terminals that you need. Dave
@Tottenham1981
7 жыл бұрын
hello dave?we have a gloworm 18hx, boiler. only three years old? F22 keeps coming up on the panel..reset it? but no heating. tried to check the pressure, but its a sealed unit from the bottom of the boiler? if its a major job? do we need to call an engineer in? some are charging £99 for the 1st half an hour... extortion or what. help please? 😩
@DaveLane1964
7 жыл бұрын
stephen mendoza it will be the pump or no water in the system that's causing the problem! Yours probably isn't a pressurised system. I think you need to call an engineer! Dave
@Tottenham1981
7 жыл бұрын
ok dave? thanks for the reply?
@sis888
5 жыл бұрын
Thank you so much you’ve saved us money and frost bitten toes 🥶👍🏻👍🏻 It worked straight away.
@marius6116
5 жыл бұрын
Just fixed it , thank you for the video ;)
@robregist
4 жыл бұрын
Brilliant, despite the chicken. Wish I'd found you a few years ago!
@Bikaneri1
3 жыл бұрын
Many Thanks Dave for sorting F9 Faults - wish i had seen it before. To sort this recurring problem called local engineer, who changed two auto air vents, Pressure sensor and also charged for Glow worm 0020020731 electrode product code (??) I gave him full installation manual, which he found useful. Just a query - the firm said it is a part fixed in the heat exchanger . Does a code becomes a part !! Any views on it.
@DaveLane1964
3 жыл бұрын
Hi gian sorry I don’t know what you’re asking me! Dave
@Webowebo8
8 жыл бұрын
Hi Dave, unsure as to whether you're able to help, (wish you were further south of the country) we have a flexicom HX18 had a code of F1 and F4 and occasional F22, engineer has been out, replaced the ignitor, followed by the PCB and gas valve, now our boiler makes an awful churning and vibrating racket when we fire it up, engineer says it's the heater exchanger and nothing further can be done, needs a new unit, any ideas, appreciate any input that you might be able to offer ?. thanks Joe
@DaveLane1964
8 жыл бұрын
Webowebo8 hi Joe unfortunately it sounds like you've had a bad engineer!! F1 and f4 is usually the electrode that needs replacing!! The noise you're describing is the gas valve out of calibration. It needs setting up with a flue gas analyser. You need someone that knows what they're doing!!I know you'll now have spent a lot of money but might be best getting glow worm to sort it!! They do a fixed price repair of about £250!!! Dave
@Webowebo8
8 жыл бұрын
David Lane Hi Dave, thank you so much for taking the time to reply, fully appreciate that time is money and you taking the time is nice to see in this day and age. The engineer has replaced the ignitor and the gas valve and checked the pressure/flow? but it's a weird one, the noise has now gone, since I wrote this morning and furthermore, it seems to be working OK again now ???.. we have, since this morning however, been onto British Gas to get a quote for a new boiler as we're both fearful of it packing up altogether over the coming weeks into Xmas ...
@DaveLane1964
8 жыл бұрын
Webowebo8 I can understand why you would want to change it however there really isn't much in the boiler so once it's fixed it should be fine for years to come! If you've decided you want a new one go one gassaferegister.co.uk and you'll be able to find installers close to you that should be able to give you a better price than BG! If you buy from BG they will only give you 1 year warranty but if you get anyone else you will get between 5 and 10 years!! Dave
@Webowebo8
8 жыл бұрын
Again, thank you very much :-)
@ministerforships
6 жыл бұрын
Thanks for the video Dave. I've been keeping the heating and hot water going using the top-up trick for a week now, and I've got a spare sensor. How do I drain the boiler? Is it the same as draining the whole system?
@g20gasservices
6 жыл бұрын
Hi assuming you’re confident to work on your boiler here’s a breakdown. Close the flow and return valves under the boiler using a 4mm Allen key. Open both the drain cocks that are on the flow and return valves and put 2 buckets under them. Take the cover off and remove the condensate trap then remove the clip and the pressure sensor. Quickly push in the new sensor as water will come out. Job done. Good luck
@WhatElseNow
3 жыл бұрын
Thank you - Problem fixed. :0)
@nicolahodges2
10 ай бұрын
Thank you i did what you said but it hasn’t worked so had to call engineer but thank you for your help 👋
@jietee
6 жыл бұрын
Great video, thanks. My boiler is only making 2 noises when the reset button is pressed and no pump trying to start up. Does this sound like the pump?
@g20gasservices
6 жыл бұрын
Yes unfortunately it does 🙁
@jietee
6 жыл бұрын
G20 Gas Services thanks for the quick reply. I searched for the new pump price and it looks to be around £180 for the part. Just need to get a quote for fitting it.
@sarahmark2
4 жыл бұрын
Thanks for posting, a great help....
@stevenwilliams520
6 жыл бұрын
dave, superb video. i had a new pressure sensor fitted tuesday, old one full of dirt, plumber thought that was the cause of the f9. two hours after he left f9 again, he told me to bleed the rads as there must be air in them which there was in one. f9 appeared a few more times that day i kept resetting and checking pressure which were all ok. it ran for two days perfect then f9 ! i thought it was solved. do i just keep going here as it may just be some more dirt in the system ?
@g20gasservices
6 жыл бұрын
Hi Stephen if you press the reset button and watch the pressure it should increase by at least 0.1 bar after about 6 seconds when the pump kicks in. If it doesn’t ever show a pressure increase then maybe expansion vessel pipe blocked or expansion vessel low in pressure. If it does show an increase then something must be sticking occasionally to cause f9! Could be sensor or pump. Good luck
@stevenwilliams520
6 жыл бұрын
G20 Gas Services I’ve had a new expansion vessel a few weeks ago and pressure valve this week. The pressure does go up when it is reset. I have noticed that when you reset the boiler for the first two seconds the bar shows 1.0 which is different to the 1.4 bar when the boiler is at rest. Are they two different readings and if so could that be the answer?
@g20gasservices
6 жыл бұрын
If the pressure goes up to 1.4 bar when the pump is running proves that the problem isn’t with the expansion vessel or air in rads! I’d say it’s still pressure sensor problems maybe caused by your system water! A flush and a double dose of inhibitor would be my next move!
@jwcgaming2215
5 жыл бұрын
I have a glow worm flexicom 30cx same as this in your video,my problem is I have no hot water,central heating is ok. On the digital display there is no tap symbol when I turn on to continuous??ANY ideas m8.
@g20gasservices
5 жыл бұрын
Hi you really need to get a heating engineer to look at it as it could be several things and unless you’re in front of the boiler it’s very difficult to diagnose. Dave
@onrd1775
3 жыл бұрын
Legend
@Tomjroberts3
5 жыл бұрын
Worked a treat - cheers Dave
@scottelparaiso1579
7 жыл бұрын
Dave, we have a 2008 Felxicom 24cx. Will a new Flexicom 30cx go on the same pipework without requiring any alterations? I ask because we need a new boiler but the old pipework is behind a built in kitchen and its going to be a nightmare to change. Thanks in advance.
@DaveLane1964
7 жыл бұрын
Scott El Paraiso hi yes it will go directly on. They are discontinued now though but I know plumb center still have some. Regards Dave
@michaelcolgan2742
6 жыл бұрын
Thank you so much Dave your expert and kind knowledge has provided me and my girlfriend with a warm Christmas. Kindly appreciated. 👍
@g20gasservices
6 жыл бұрын
Michael Colgan glad to help. Have a great Xmas
@timeintheuk
5 жыл бұрын
On the older glowworms f9 can be caused by the overheat stat . If when resetting a presure is shown check the hi limit stat
@g20gasservices
5 жыл бұрын
phplumbing53 yes on the older cxi boilers F9 is a generic code so it will throw it up if the pcb doesn’t know what the fault is. F5 is the overheat stat. Dave
@mchardyplumbing
Жыл бұрын
changed pressure sensor pcb board and pump still got f9 any ideas
@Terry2868
Жыл бұрын
I have to top mine up 4 to 5 times a day but council say the nothing up with it I don’t have any leaks in the house been like it for about 9 years
@jyt2394
4 жыл бұрын
This is a recurring thing for my boiler, happens 1-2 times a week now, usually after it’s been on a while the day before. Works just fine after I reset it, how do I stop it from happening?
@g20gasservices
4 жыл бұрын
Jack Robbo make sure all your radiators are bled then maybe get a heating engineer to replace the pressure sensor
@reginapourdad2780
Жыл бұрын
Dave how do I bleed the radiators ?
@1969horatio
7 жыл бұрын
Hi Dave Good video I've an ultra com 30sxi and keep getting the f9 I've replaced the sensor. Added an expansion vessel. Prv.Changed the pump. Pressure is constant now but still getting f9. . I've two zones.The boiler calls but doesn't fire up always and keeps trying to f9. Sounds like some air but I've bled all the rads. I haven't looked at the filter yet. Any other ideas? Thanks
@g20gasservices
7 жыл бұрын
Hi is it definitely an Ultracom sxi and not just an sxi? Ive looked up the code for the Ultracom sxi and it says it doesn't use F9!! Dave
@jdjohndavie
8 жыл бұрын
Where are you in the country David?
@michaelstowers101
6 жыл бұрын
Thank you, the pressure tip solved my problem
@symonrasheed1066
7 жыл бұрын
Hi Dave thanks for helping me, I have got Glow worm Flexicom 24cx, pressure 3.1 I believe this pressure is more than normal. how could I reduce the pressure??? thanks
@symonrasheed1066
7 жыл бұрын
boiler showing F9 fault
@sheilareynolds2054
5 жыл бұрын
Hi Dave don't suppose you know why from F9 mine then goes to flashing between 02 to 03 what does that mean ?
@g20gasservices
5 жыл бұрын
Sheila Reynolds not sure! Have you pressed the reset button and tried topping up the pressure?
@sheilareynolds2054
5 жыл бұрын
@@g20gasservices yes did all that but thought I would ask anyway .thank you though
@trevedwards3812
6 жыл бұрын
Hi Dave, I have a glow worm flexicom 18sx and I have an intermittent problem. It comes up with fault code F9 and after I reset it sometimes it works fine straight away but sometimes it will continue to say F9 but a couple of days later it will work again for about two days then the fault code comes up again! I’ve had an engineer come and take a look but it worked fine while they were there! Any ideas? Thanks!
@g20gasservices
6 жыл бұрын
Hi Trev it will be the pressure sensor that needs replacing! They get blocked up but as they’re only about £30 it’s not worth cleaning it. Dave
@onrd1775
3 жыл бұрын
Thank you Thank you Thank you
@stewartharrod8562
3 жыл бұрын
Any advice on the f22 fault
@BaronVonTrumplton
Жыл бұрын
You absolute legend!
@wittywoo9559
6 жыл бұрын
Hi my gloworm 30sx displays f9 after 4efforts to start , is the whirring noise at the start the fan or pump starting ?
@g20gasservices
6 жыл бұрын
Witty Woo the first thing that comes on is the pump. If it’s making a loud noise it possibly needs replacing!
@wittywoo9559
6 жыл бұрын
G20 Gas Services thanks for replying !! wasnt sure , its making its normal start up noise sounding pretty normal but just not firing , i noticed the pressure on the display is reading 1.3 but doesnt move when the pump starts ???
@g20gasservices
6 жыл бұрын
Witty Woo ok have you tried all the things I’ve said in the video? If so then maybe just a new pressure sensor!
@wittywoo9559
6 жыл бұрын
G20 Gas Services yea tried that , ive ordered a pressure sensor , ill just have to replace it and see if what happens , the boiler is only 5yr old , the lad who usually does the service on it retired this year , thanks again
@wittywoo9559
6 жыл бұрын
G20 Gas Services hey Dave , turnes out it was a pressure problem , the reason i didnt realise this is cause the display was telling me pressure was at 1.3 bar , but when when i pulled the blow off (just to see), noting happened , so i pressurised the system as normal & she fired up , happy days .... why would i get a wrong pressure reading on display ??