In this fire fighting video, we'll be talking about the fire fighting pump room installation mistakes NFPA 20 in Urdu/Hindi. Here are explained 11 fire pump room mistakes that need to be avoided during the installation of a fire fighting system in reference to NFPA 20. We'll also be giving you a brief introduction to those mistakes and their remedies. If you found anything which is inappropriate in this video then convey it in the comments for information and rectification in the future.
00:00 Introduction
00:57 Fire fighting Pump Room Mistake 1 Anti vortex plate
02:30 Fire fighting Pump Room Mistake 2 Negative suction
04:53 Fire fighting Pump Room Mistake 3 pipe connection
09:01 Fire fighting Pump Room Mistake 4 Strain relief
10:19 Fire fighting Pump Room Mistake 5 Valves installation
11:36 Fire fighting Pump Room Mistake 6 casing relief valve
13:10 Fire fighting Pump Room Mistake 7 pipe flow meter connection
15:01 Fire fighting Pump Room Mistake 8 pressure relief valve
16:58 Fire fighting Pump Room Mistake 9 OS&Y gate valve
18:01 Fire fighting Pump Room Mistake 10 Check Valve
18:42 Fire fighting Pump Room Mistake 11 Pressure Sensing Line
Tanweer Ahmed firefighting more videos for your watching:
1. NFPA-14 Pipe Schedule Method for Standpipe
Video's link: • NFPA 14 Pipe Schedule ...
2. NFPA-14 Flow Rate Requirements for Standpipe & Hose System
Video's link: • NFPA 14 Flow Rate Requ...
3. NFPA-14 Pressure Design Requirements of Standpipe & Hose System
Video's link: • NFPA-14 Pressure Desig...
4. NFPA-14 Classes of Standpipe Systems
Video's link: • NFPA-14 Classes of Sta...
5. NFPA-13 Pipe Schedule Method Designing
Video's link: • NFPA 13 Pipe Schedule ...
6. NFPA-13 Sprinkler Heads Distribution
Video's link: • NFPA-13 Sprinkler Head...
7. NFPA-13 Density & Area of Sprinkler Operation
Video's link: • NFPA 13 Density & Area...
8. NFPA-13 Sprinklers Discharge Characteristics
Video's link: • NFPA-13 Sprinklers Dis...
9. Wet Riser Landing Valve System
Video's link: • Wet Riser Landing Valv...
10. Testing of Wet Riser Landing Valve System
Video's link: • Testing of Wet Riser L...
11. Fire Hose Reel System
Video's link: • Fire Hose Reel System ...
12. Testing of Fire Hose Reel System
Video's link: • Testing of Fire Hose R...
13. Where PRV is required as per Pressure in Firefighting System?
Video's link: • Where PRV is required ...
14. Combined Firefighting System Water Demand
Video's link: • Combination Standpipe ...
15. Types of fire sprinkler systems fire suppression systems
Video's link: • Types of fire sprinkle...
16. Sprinkler Deflector Position NFPA 13 Unobstructed
Video's link: • Sprinkler Deflector Po...
17. Sprinkler Deflector Position NFPA 13 Obstructed
Video's link: • Sprinkler Deflector Po...
18. NFPA 13 Sprinkler Distance Below Slop Ceiling
Video's link: • NFPA 13 Sprinkler Dist...
19. Supervisory Valves in Firefighting
Video's link: • Supervisory Valves in ...
20. Riser Check Valve for Wet Pipe Sprinkler System NFPA 13R
Video's link: • Riser Check Valve for ...
21. Alarm Check Valve Assembly - ACV Complete Detail
Video's link: • Alarm Check Valve Asse...
22. Inspectors Test & Drain Valve for ZCV Assembly
Video's link: • Inspectors Test & Drai...
23. Fire Fighting Systems for Healthcare Facilities
Video's link: • Fire Fighting Systems ...
#tanweerahmed #firefighting #nfpa20 #pump #room #fireprotection #sprinklers #firesprinkler #wet #dry #sprinklersystem #tutorial #construction #mep #fire
= YOU CAN FOLLOW ME ON SOCIAL MEDIA =
WEBSITE: engineertanweerahmed.com/
FACEBOOK: web.facebook.com/EngrTanweerA...
INSTAGRAM: / tanweersethar
LINKEDIN: / tanweer-ahmed-00142631
KZitem: / tanweerahmed
TIKTOK: vm.tiktok.com/ZSJReMqYx/
TELEGRAM GROUP: t.me/hvacmepenggg
Негізгі бет Ғылым және технология Fire Fighting Pump Room Installation Mistakes NFPA 20 in Urdu
Пікірлер: 99