Thanks a lot o was looking for this for a long time but didn't find much info. The span I have is 22 ft. Columns 9*14inches, 4 bars16mm and 2 bars 12 mm door/lintel beam is 6inches and the roof beam is 12 inches deep 16mm bars. Will it be sufficient?
@engrraufkhan9876
2 жыл бұрын
Nice lecture,sir Explain Difference between Tie beam and plinth beam
@bollusrinivas
2 жыл бұрын
Column size 9/15 with 6 Rods(16mm 4bars and 12mm 2bars with 8mm rings @6inch) and distance between two columns is 15.8feet. two rooms, each 12feet/15.8feet. Footing 6.5feet depth width 4x4, with 1feet 40mm and 2.5feet 20mm. Is this good for g+2 residential building?
@venu511
2 жыл бұрын
Good video sir..more information 👌👌👌👌
@KusaasiraNoah7421
2 жыл бұрын
can you use 16mm diameter bars in columns and 20mm in beams?
@kennethwhite5158
2 жыл бұрын
Sir, If we have four steel rods on the bottom of the beam and three steel rods in the column to tie off to how is it possible to tie the two middle rods in the beam to one middle rod in the column? I'm confused.
@anilshukla8075
2 жыл бұрын
Excellent knowledge
@fasterfaster5960
2 жыл бұрын
Baraka lahou fikkk
@pradeepSuriyabandara
Жыл бұрын
Thanks for the lesson what about if this G + 2 story with 5 ton of load
@ameehasa5504
2 жыл бұрын
How many crank bar we should use? I hope if u have video for framing on all type of soil
@dreamer69223
Жыл бұрын
Is 12mm 5 bars, 16 mm 1 bar enough For 14 feet beam ( top 3 - 12mm, bottom 2 - 12mm and 1- 16 mm)??
@mohammadmuslim5694
2 жыл бұрын
Good lecture
@faruqahmedbusiness1105
2 жыл бұрын
Will you show the analysis. Formula or thumb rule for column and footing design like beam depth formula l/20 for depth.
@murthyau6620
2 жыл бұрын
Can we know from you, the load bearing of our existing Residential structure, to go for further floors, at professional consultation. Then how to communicate, please. Regards.
@ph6263
2 жыл бұрын
Sir My newly constructed house have one of the beam of length of 5.2 m (16.5 ft) and one secondary beam is tested on it. It is 230×300mm but we used 4 no of steel bars of 16 mm at bottom and 2 nos of 16 mm + 1 no of 12 mm at top. So ll it sustain to that amount of load for longer period or developed crack??? As I see many engineers recommend more than 450 mm deep beam.
@syedabdulquddus3469
2 жыл бұрын
supper sir, Thank you very much
@amols9634
2 жыл бұрын
L/20 for 19 feet span 285mm depth so safer side you have to take 230x 380
@phyohtetkoko929
Жыл бұрын
Thanks For Teaching Sir
@hemantasingh8606
2 жыл бұрын
6 nos of 16mm in beam (10X12) for 20 feet span.column (12x12) 4 nos 16mm &4 nos 12mm for single room .can we build g+2?
@kswvidioyoutube8816
2 жыл бұрын
It's possible even I'm doing my own house with four 16 mm andtwo 12 mm in one biller size is 8/10
@byrappakaramaradi4070
2 жыл бұрын
What should be the height of building?
@waluohopaulo2116
2 жыл бұрын
Well understood
@defersonlyngdohmawlong708
2 жыл бұрын
G 1 G2 G3 means what? Does it mean 1floor 2floor
@moamar7585
2 жыл бұрын
what is the thickness of footings?
@muruganmuthusamy9976
2 жыл бұрын
Fine
@khan52310
2 жыл бұрын
If I have 24 feet span and other side is 26 feet span for G plus 1 story home only, please reply
@UmeshSahu-di2ee
2 жыл бұрын
Wow bhai....
@paonamdineshmangang6179
2 жыл бұрын
Sir is it OK to put 4 Steel rod of 16mm on top and 4 on bottom of 17.5 feet long beam
@ariezaziziacahlebih2637
2 жыл бұрын
Salam sir, does this can apply to 21 ft span?
@Mithushahome
2 жыл бұрын
Super bro
@namahshivay8978
Жыл бұрын
Thanks 👍❣️
@kaungsettlinn1179
2 ай бұрын
ACI code(Beam is. span× 0.75=beam depth)
@ayaan5633
2 жыл бұрын
Can you do your future video measurements in feet and inches.?
@sridharsahoo489
2 жыл бұрын
Sir u could not say top reiforcement which mm bar used in this video
@akojuravisankar3492
2 жыл бұрын
Thank you for giving good information about construction building.
@salimmahmud1614
2 жыл бұрын
Maa shah Allah
@intkhabahmad453
Жыл бұрын
Steel volume should be 1-2% of RCC volume for beam. Calculate it
@premjitchakpram4201
2 жыл бұрын
How about if we made column size 12x12 for G+2 residential house with steel rod of four 16mm and four 12mm?
@ramakantsalam6132
2 жыл бұрын
Totally safe
@alisherkhan5347
2 жыл бұрын
Waiting for response too
@ningthoujamnewtonmeitei5137
2 жыл бұрын
Sir can it apply in normal residential building
@manjunathbc3655
Жыл бұрын
What should be size of beam and column and size of steel which is 7 meters and roof size and steel size G+3
@aemisection4460
2 жыл бұрын
please post a video for culvert reinforcement details and designs
@lakshmanang8316
2 жыл бұрын
I have one doubt , In your previous video you say As per Indian standard min depth of beam is d/16 = 19/16= 1.2 ft but you say now 1 ft is enough . how !?
@jaiharris6606
2 жыл бұрын
L/20
@muhammadtahirmushtaq6300
2 жыл бұрын
good mashallah
@lakshmanang8316
2 жыл бұрын
Need plinth beam design
@chatpatgamingyt2707
Жыл бұрын
What will be the size of footing for same building if soil bearing capacity is 70kn/m2?
@SandeepKumar-eg1kw
Жыл бұрын
It is good decision to choose deep foundation than shallow foundation if you cam to know soil is till 70kn of bearing
@himangshupatra5000
2 жыл бұрын
SIR I HAVE 16 feet span G+1.stroy, i have provide beam ( 9 inch *12 inch ) , with 16 mm 2 bar, and 12 mm 1 bar at bottom, and 2 bar of 12 mm at top with 8mm stirrups @150mm c/c spacing, is it safe?? Also column size -(9"*15")
@ayaan5633
2 жыл бұрын
absolutely save for G+1
@trishan2739
2 жыл бұрын
Can you explain that what is column and beam size with how many steel used with size Also length and width distance of each column
@kswvidioyoutube8816
2 жыл бұрын
Very nice explaination but not for the poor peaple it's too much and it will be very expensive less size column beam can biuld G+2
@nyantehemmanuel7089
6 ай бұрын
maximum span between columns
@izharulhaq8435
Ай бұрын
And calculate the no. Of beams for 40 by 16 feet
@ramakantapradhan7932
2 жыл бұрын
If column to column clear span 19', i want provide 6 nos 12mm bar in column and in beam 16mm 4nos bar, any problem plz solve it
@ramakantapradhan7932
2 жыл бұрын
Plz any comment
@engrijazali282
Жыл бұрын
if the span btween 2 column is 16ft...and the building is G+1+2 than explain size of column and beam...
@logisticsh.n.a.a4136
2 жыл бұрын
Do pakistan and india have the same engineering principles for rcc construction .
@MehrbanRana
2 жыл бұрын
Dear All over the world is same principles. Even here in GCC countries are same principles.
@logisticsh.n.a.a4136
2 жыл бұрын
@@MehrbanRana thanks .
@musahhamid5461
2 жыл бұрын
Pls I need picture of G+1 and G+2 story building
@palashmatubber8496
Жыл бұрын
I love u sar
@DeepakKumar-oo9si
2 жыл бұрын
18fit distance mi kon sa colum lgta hi
@mpannirselvam9512
Жыл бұрын
36/60 what is the size of the pillar snd besm
@izharulhaq8435
Ай бұрын
No. Of beams used for 40 by 16 feet
@awishhamza6368
5 ай бұрын
12x9'' beam isn't safe for 19-20 feet span in beam column structure. do stress analysis
@izharulhaq8435
Ай бұрын
Please answer my question
@intkhabahmad453
Жыл бұрын
Your beam steel is not correct for 19 ft span... Moreover depth of beam is also very less for 19 ft... It should be minimum 19 ft... Rest of the calculation and suggestions are well.
@shanjaiks7583
2 жыл бұрын
We are watching a religious programe . Inshallah
@nawalshrivastav6032
Жыл бұрын
Please hindi Language used.
@muhammadafzaal8670
2 жыл бұрын
Agr urdu mai lecture daitai to aor acha hota......
@252adeshpatade3
2 жыл бұрын
Sir for 3 storey house 6 no 12mm bars are sufficient or not Column size 9 * 15 " Please guide