Thanks for video, could you please tell me if I have 2 K636 keyboards, how should I define them?
@sedky69
10 ай бұрын
I am not familiar with that one, but based on the manual it is compatible with SP and MG series, so I assume it is the same as the K10H. Just a different look. I mean there is nothing to program for a keypad. If it doesn't work it may be a very old model for the Esprit line up.
@costelflueraru2442
7 ай бұрын
Hi there, Very nice and informative. Thank you! You said you will do a training on the zone definition. Did you? What is zone speed? and how to use it? I have many more questions. Thanks
@sedky69
7 ай бұрын
I haven't done any new trainings yet. I hope to do in the new year.
@higchannel
3 ай бұрын
Regarding Input speed, you can adjust it to increase or decrease the signal response time in that zone. eg: default 60 input speed allows the sensor to respond immediately however you can adjust it to increase response time to 2.3 or 4 seconds
@KhalidSulaiman-fx5bk
Ай бұрын
Great Video. Can you please help me to trigger the alarm if a zone/door is opened for more than 5 seconds? I created a Zone to act as a Panic and connected a 3rd party receiver and remote to activate it. I only want to trigger the Alarm if I hold the button down for 5 seconds.
@sedky69
Ай бұрын
Let me get back to you on this
@gabortoth3374
3 ай бұрын
can you protect the panel with a door sensor in the box without assigning a zone to it?
@sedky69
3 ай бұрын
I don’t know. I would use a zone if it is needed.
@DanielsGameVault
11 ай бұрын
Can you still access the IP150 from a web browser after firmware version 4.0 ? I just bought an IP150+ (PLUS) and the web interface refuses to load. "IP Exploring Tools" detects the module but I can't change any settings, not even the IP address from DHCP to static - it asks for the password, it SEEMS to work, but in reality nothing gets applied. The HTTP port is zero by default, so the browser refuses to connect to it...
@sedky69
11 ай бұрын
4.0 is a buggy firmware. Try to upgrade to 4.2 or above. Actually once you try to upgrade it will automatically take you to 5.2. You should be able to access the web interface after.
@TheTalkmanLarry
8 ай бұрын
Hey, I have a motion sensor on NC but it stays open. Any ideas that can help me fix it? The wiring is good I know that but maybe something in the settings?
@sedky69
8 ай бұрын
Check it with the meter. Also check the manual and make sure if there are jumpers they are in the correct position. If it is defective it will have to be replaced.
@gabortoth3374
3 ай бұрын
Hello. How do you setup that the keyboard panel shortly beeps 3 times whenever you open the front door? My one does this but I cannot find it in Babyware. Thank you.
@sedky69
3 ай бұрын
Check my video muting/unmuting a zone
@gabortoth3374
3 ай бұрын
Thank you. Your videos are really helpfull!
@costelflueraru2442
7 ай бұрын
Hi I am looking forward to the the training video about the zone setting. 1. I am not sure how to set the access code (to arm/disarm) for a simple house security setting using Babyware. I know how to do it using the keypad. In Babyware there is a large number of users... while in a house setting I was using one code for arm/disarm. 2. I am dealings with a situation in which Babyware reports no trouble while the keypad shows trouble (no wireless bell!?). I do have few wireless windows contacts in the system (SP with an RTX3) but I never used or set a wireless bell. Not sure where is coming from.. Many thanks,
@sedky69
7 ай бұрын
What is the trouble code?
@costelflueraru2442
7 ай бұрын
The key pad flags a trouble. When checking it show missing module: wireless siren. I have never install or use a wireless bell. Not sure how it was added to my system. most likely is a default setting. However when open up Babyware there is no trouble list. Any suggestion is highly appreciated. thanks
@sedky69
6 ай бұрын
@costelflueraru2442 Have you tried a module scan? Section 955 for the SP and MG series. Tell me which panel you are using and which lights come up when you press TBL. Also once this light comes up, press it and tell me what lights (digits) come up next.
@costelflueraru2442
6 ай бұрын
The system is SP7000+, K32LCD, K10V/H and RTX3 with 5 wireless contacts. On the keypad (K32LCD) is shows Trouble Press TBL. I press TBL then keypad shows: Missing Module{arrow up} [0] to View {arrow down}. Press 0 then keypad shows Missing module{arrow up}, Wireless Siren {arrow down}. Pressing arrow up again it cycles: Missing module{arrow up}, Wireless Siren{arrow down} when press again changes to Missing Module {arrow up}, No trouble {arrow down} continuing to press the arrow will cycle between this two messages. No other knob/digit is lighting up! It is annoying! Babyware shows no trouble!
@sedky69
6 ай бұрын
@@costelflueraru2442 I have a couple of suggestions, but I have never dealt with this panel or a wireless siren before. Check sections 587 options 3 to 6. Set them to off. Also sections 683 to 686, make sure there are no serial numbers there for the wireless siren. sections 691 to 694 same. Section 695 press enter. Once confirmed there is actually nothing programmed for a wireless siren do a module scan section 955. It will clear any trouble related to a non existing module. You can try section 955 before you do all this actually. Let me know what happens. If not there is always the possibility that the panel is defective.
@user-wv3fs2bg1z
Жыл бұрын
hi there. i really liked ur tutorial. can u plz tell me the zone doubling concept. how to configure in baby ware
@sedky69
Жыл бұрын
Thanks for your comment. I have never used that ATZ setup so I am not able to advice on it at the present time.
@nguyenbrian754
3 ай бұрын
U only need tick ATZ function in zone configure section and installation like this Installation manual. eg: u use SP4000, ai zone 1 on panel is zone 1-5 on babyware and 2-6,3-7,4-8. zone 1234 use register 1K, ZONE 5678 use register 2k2
@costelflueraru2442
7 ай бұрын
Sorry in my previous message I was referring to input speed not zone speed. so what is input speed and how to use it? thanks
@sedky69
7 ай бұрын
I never experimented with that, but here is what I see from the manual: "The Input Speed defines how quickly the control panel responds to an open zone detected on any hardwired input terminal (does not apply to addressable motion detectors and door contacts)." I could see this being used with zones that are falsing too often, but I haven't tried it yet, so try it out in a controlled environment before you use it in the field.
@gabortoth3374
3 ай бұрын
hello. Thanks for the video. What is the exact sequence to retrive the panel ID and PC passoword using MG32I?
@sedky69
3 ай бұрын
Hi. I am not sure what the MG32I is. I don't see it on the paradox site, but generally panel id and password are sections 910 and 911 respectively. From the start, press Enter, press installer code, press 910, the numbers are going to light up according to the panel id. You press the same number as they light up to move to the next number. Once you reach the end of section 910, it automatically goes to section 911. Follow the same process.
@gabortoth3374
3 ай бұрын
@@sedky69 My mistake, i have K32IRF keypad. And after entering 910 one of the zone incitacor is shown olny (10). Should I prees 1 and 0 to move to the next part of the panel ID? (I am asking because it is weird that I did not get single digit prompt. The panel is SP6000. Thanks for the further hints
@sedky69
3 ай бұрын
@@gabortoth3374 Watch my next video and let me know if it helps. It should be ready in 30 mins or so.
@SamirTawfikTec
Жыл бұрын
بشمهندس هل ممكن اركب اكثر من اتنين حساس حركة سلكى NV5 على زونة واحدة MG5050
@sedky69
Жыл бұрын
أنا مجربتش فمش عايز أفتي. عادة بالنسبة لحساس الحركة بنحط واحد بس في كل زون. لو محتاج أكتر من واحد بتوصلهم علي التوازي
@SamirTawfikTec
Жыл бұрын
@@sedky69 انا موصل 2 و شغال تمام بس انا كنت عايز احط 4 حساسات فى الزيونة الواحدة الف شكر على الرد
@chuj9288
8 күн бұрын
when i am trying to connect to babyware with the mg6250 it requires panel id/ pc password where can i found the panel id of mg6250
@sedky69
7 күн бұрын
Have you tried to login to the panel from the keypad and finding that out? This one seems different. I am not familiar with it, but the default username and password is admin for both
@chuj9288
7 күн бұрын
@@sedky69 I have tried everything, even to section programming with 3011 and 3012 also with 910 and 911. I cannot find the panel id and pc password and when I try to connect with babyware it will not connect
@sedky69
6 күн бұрын
@@chuj9288 From what I see this is a different type of panel. It seems you have to scroll through the menu. Check page 28 of the manual steps 7 and 8. If not you will have to contact your dealer. I am not affiliated with Paradox.
@Frank-yz6ih
3 ай бұрын
Hello can you please Help me. On the evo192. The newest Software ist Always askimg me to Change the Default Panel ID and Password But dont Accept any number or Letters , before i changed the Login. What ist my mistake?
@sedky69
3 ай бұрын
You can download an older version of babyware. Older versions don't force you to change the password, but the password should not be left at the default. You can also try to change the id and password using the keypad. For evo it is sections 3011 and 3012.
@sedky69
3 ай бұрын
For troubleshooting, disconnect from babyware and see if you are able to login to programming from the keypad