@@TedCookHVACwish that could be said about Trane nowadays I have had a bunch of defective evaporator coils they all seem to be a 2019 model
@pepperstinson3141
Жыл бұрын
Lack of maintenance destroys just about everything in our “mechanical” world. Brand doesn’t matter.
@549BR
Жыл бұрын
Well, at least their wasn't a casket in that lower level. If I'm not mistaken, this one falls into the kicking of the can; as in down the yellow brick road. Another high quality production from the soft spoken SC gentleman. 😎
@sknight0391
Жыл бұрын
Halloween's right around the corner. 😎👍
@TedCookHVAC
Жыл бұрын
Oh yeah!
@CoolChris2023
Жыл бұрын
I have been using the stubby gauge with core depressor removed for quite some time now. I must admit I got the idea from one of your older videos. Works great and is the first thing I check on older packaged units especially if they have CoreMax high-flow valves which are prone to leaking. Your videos are very enjoyable, thank you.
@davidwinfrey3307
Жыл бұрын
Ted I've been watching your videos for10 years and I think you always make the best call
@TedCookHVAC
Жыл бұрын
Thank you very much for watching! I really appreciate it! What area do you live in?
@robalexander7348
Жыл бұрын
That was a thorough coil clean up Ted, here in Australia we are in for a Hot summer, it's still winter here and already the trees have burst there green leaves, stay cool 👍 Au
@eastcoast186
Жыл бұрын
Quality old school service call thanks 👍👍👍
@Eddy63
Жыл бұрын
Ted your neighborhood must not be to ''Cool '' your always doing no ''Cooling'' calls in there Good vid my friend ... Thx
@Tarpon65
Жыл бұрын
Always enjoy the videos.
@jasona1567
Жыл бұрын
You hear that landscaper making noise with the blower in the background. I guarantee he is making you another customer with dirty coils.
@Hvac-dude
Жыл бұрын
Thats a dirty coil !!! Good job 😊😊
@aspenschroeder6117
Жыл бұрын
Thank goodness for Goodman. Keeps us busy
@jeffsworld2
Жыл бұрын
I hate the way Goodman units fade so much in the sun. Makes the unit look older then it is.
@bbizzle82
11 ай бұрын
hard to stop a goodman
@chrissipple1018
11 ай бұрын
That idea with just the gauge has been around a long time. I was using just the gauge in 1979 when I started in the trade. It was my boss idea for a quick check of pressures.
@throttlebottle5906
Жыл бұрын
at 1:28 is that an Ted Cook doll? 🤣🤣🤣 totally joking big brother. 🤪
@mmccormick1520
Жыл бұрын
Good Work!
@albertmcalister9066
Жыл бұрын
Good job on coil cleaning and the leaves aren’t going to bother cooling performance. The only thing the leaves will do is hold moisture causing corrosion but if the bottom isn’t falling out of it already a couple of weeks won’t matter.
@Paul-IE-Repairs
Жыл бұрын
or plug up the drain holes
@anthonyelectric6045
Жыл бұрын
Lol I guarantee she wants it😂nice work Ted👍
@GTIMAN2010
Жыл бұрын
Thanks for the vid!
@backlineguy
Жыл бұрын
great video...where can I find that sprayer? The nozzles and pressure are excellent for keeping those coils clean...
@derekmc9580
Жыл бұрын
Do you sell surge protection when you sell your high seer communicating equipment? I never see you changing inverter boards or anything like that so I just wondered.
@junior-hk2jt
Жыл бұрын
If and when we come across a r22 system we've been using 422 since about the time it came out and haven't had any issues at the end of the day if they still have r22 system it's time to change it, why spend so much on refrigerant..
@nomusicrc
Жыл бұрын
What does a hard start do that a capacitor can't do
@rangepro
Жыл бұрын
Isn't it amazing if most people would spray out their coil with a hose, it would last longer , don't you think?
@111000100101001
Жыл бұрын
Sometimes they don’t clean em’ and sometimes a yahoo gets crazy with a 20deg tip pressure washer.
@Seedavis397
Жыл бұрын
Surprised your recharging system if your gonna replace it soon. That’s dang good customer service
@z33511
Жыл бұрын
Agreed, but with work/supply delays of 5 - 12 days, it's a merciful thing to do.
@andrewhornfeck7421
Жыл бұрын
I cringed when you used the term mini “pressure washer” as some may interpret that as your endorsing a pressure washer TO clean their coil. YES, watching your machine it was more a portable mixing device than EVER hi pressure. I really enjoy your channel!
@johnsonjay60
Жыл бұрын
Darn leakin Freon!
@tonyrhoton6613
9 ай бұрын
Wasn't very low
@nickhigh100
Жыл бұрын
What’s that box half hanging off the condenser? Thx
@HenryMancini-rg3xm
Жыл бұрын
Crap promoted by the power companies that they claim will save you money, I do most customers justice and get rid of them
@tonyrhoton6613
9 ай бұрын
Junk
@danielprice9997
Жыл бұрын
Thats a monster of a house.
@dustingerhardt9889
2 ай бұрын
You don't have to explain yourself to these "super techs."
@Seedavis397
Жыл бұрын
Z manifold came from Zach.
@danwittels5542
Жыл бұрын
You can't stop a Goodman! But I suppose you can rip it out.
@mansourramzey7711
Жыл бұрын
Thoes shrubs needs to be cut at least 3 or 4 feet away from condenser
@joeshearer1247
Жыл бұрын
I’m starting to think you are following comfort medic and only doing family and neighbors
@duramusmosley5530
Жыл бұрын
Keys to a successful business is locking down those close to you, and then they spread the word.
@TedCookHVAC
Жыл бұрын
Yes, I try my best to be as much like them as possible. They are my heroes!
@robertspadezhinton
Жыл бұрын
John Israel is the truth. The 1st tech I found fresh out of school
@thewolf8848
Ай бұрын
you are to cute for leaves😃😃
@mansourramzey7711
Жыл бұрын
I would ask the owner to cut the shrub on this side completely before installing the new one , that's your call
@scottjones7279
Жыл бұрын
Always customer first.
@zackmax7184
Жыл бұрын
She's a Crusty One Mr. GRINCH..😅
@bobbywanger8123
Жыл бұрын
👍👍👍👍🔥🔥🔥
@stex1985
Жыл бұрын
If not for Goodmans Ted would have to get a Maytag uniform.
@Austin23191
Жыл бұрын
Ted nubrite will void your warranty on that sprayer. I asked our Johnstone store when I bought mine and they've seen it firsthand destroy several of these machines
@tacocin
Жыл бұрын
👍
@tonyrhoton6613
9 ай бұрын
Wow
@sziltner
Жыл бұрын
Trim that bush back. Poor place for it to be planted. And it will probably be cut back to put a new unit in. 👍
@throttlebottle5906
Жыл бұрын
make them clean cut and clear a ten foot radius around and twenty foot height above, before agreeing to install a new unit and specify no warranty if the clearance is not maintained or just refuse to install it if they dislike it. I myself would rather be broke, than knowingly disservice others and I hate those who do so(knowingly), none of us ae perfect nor all knowing beings, so you have to judge is a nicely as possible and factor in having bad days. taking shortcuts is most always bad and will cost you/others/many more in the end and yes it most always comes back around to you full circle. most often ending with you kicking yourself in the and bunghole.(lol) or being dead from "RUSH"ing to the bottom of the oceans "Stockton" titangate implosion (whom with half a wit didn't see that coming?). life lesson one, do not play with pressure vessels, more so ones that are subjected to tremendous external pressures *compression*.
@KeeganPurcell-eq8bi
Жыл бұрын
You can buy a 30lb jug of R22 for $975 on ability refrigerants.
@Phone-sh7jg
Жыл бұрын
I had one sent to my house. For my hvac guy to use
@Demy26
Жыл бұрын
👏🏼👏🏼👏🏼👏🏼
@patmcnally6
Жыл бұрын
Ted it is Conservation of Energy yours and The customers . Especially when you will be Replacing in the Near Future.
@aspenschroeder6117
Жыл бұрын
Gosh darn. How dare you not clean out them leaves from that poor man unit
@zackmax7184
Жыл бұрын
It might be a Leaka Momma.
@Phone-sh7jg
Жыл бұрын
How old was that junk?
@tonyrhoton6613
9 ай бұрын
It was running probly a slow leak wasnt that low if it was it b froze id cleaned charged it let it run if it got low in nxt. Yr. Maybe do different cant change out every unit cause it low of freon
@frankspliff7037
Жыл бұрын
Whose hammering
@caru3257
4 ай бұрын
Of course I would’ve done better if I were a supertech. 😂😂😂😂. The company I work for doesn’t carry R22.
@trumpingtonfanhurst694
Жыл бұрын
She's not long for this world
@1decks
Жыл бұрын
She’s a leaker mama, she’s a leaker.
@Phone-sh7jg
Жыл бұрын
How's miss molly, you old leaker?
@webberfan1234
Жыл бұрын
A no cooling call
@waffalobill
Жыл бұрын
Crazy price on gas. Must be a/c is gonna be a luxury for the tich and famous. Old ppl and poor ppl gonna just die from the heat.
@z33511
Жыл бұрын
With Social Security running out of money, looks like that's part of the plan.
@jerrykorman7770
11 ай бұрын
Yup, they’re caught between a rock and a hard place: can’t afford a new system, can’t afford to fix leaks with a cylinder of R22 priced +$1,200 Almost as if that’s part of the plan
@tonyrhoton6613
9 ай бұрын
Box fan growing up never had ac until I was 30 i was hvac tech 6 yrs before I owned 1
@dong4617
Жыл бұрын
Goodmans don't fit back together without a lot of effort.
@Garth2011
Жыл бұрын
Sweet...would be good to know when it was last recharged as that could have been a year or two or up to 10 years ago etc. The condenser was filthy dirty. I'd have told the customer that bush is getting a hair cut if they want HVAC servicing. There's no point in leaving that Holly alone when its invasive to the HVAC performance and in servicing. I'd like to blame much of condenser dirt build up from gardeners and their leaf blowers stirring up the surface soil and debris to do their job while the condenser is running and pulling it all inward. Great idea on the Schrader check. Really like how that coil jet works and that it has tips to do various spray patterns. I use it all the time even if no cleaner is required on a job, lots of homes have crap water pressure and access to hose bibs.
@97Napkins
Жыл бұрын
lol I woulda done a worse cleaning job. foam up just the outside with only nubrite. lot more foam then spray it through with no top off. Its old and probably leaking. coil would be way cleaner and great super heat. i be gone like flash
@MrElemonator
Жыл бұрын
HVAC Shop talk says great things about Goodman 🫶🏻
@tuffram2165
Жыл бұрын
Ted I know you are old a wise and I have learned a tremendous amount from certain things you do running your business but this young buck needs to give you some advice. Please start locking your van when you get something out or walk away from it. Your tools are your livelihood and there are tons of scum of the earth just looking to take from us what we have worked so hard to acquire. It might not happen today or tomorrow but it will eventually. I know locks only slow them down but why give the easy quick access to your tools and refrigerant jugs.
@hvac_audaz_firme
Жыл бұрын
Ted, I also know you're a wise man. Having said that, I'm going to agree with @tuffram2165, it's a strong suggestion that you close and lock up your work van when you're away from it. Too many individuals looking to get some high quality tools at a 5 finger discount. You're great man Ted and I'm learning so much from you sir. Happy Hvac'n
@tonyrhoton6613
9 ай бұрын
I agree nomatter how many times I go 2 truck when I leave its locked some areas worse than others but u never no.
@Cocoa887
Жыл бұрын
Removing leaves is a waste of time and money
@97Napkins
Жыл бұрын
coil clean and charge approx 4lbs but scale will say for sure. also add leak seal. $800 to $1000. if leak again then replace it. credit some back towards replacement depending on amout of time it lasted. I do these all day 🤑Im not chasing micro leaks on every call in hot attics. leak search only if empty or extremely low. this Job 1hr max
@Demoralized88
10 ай бұрын
Hey at least you're honest that you're a scammer
@steveg5576
Жыл бұрын
Was this supposed to be educational...? 🤪🤪🤪
@97Napkins
Жыл бұрын
dont need sit there with a gauge.. every call I soap bubble service valve if no bubble then i replace with brass caps and tighten with pliers...It wont be leaking. i keep a small bottle of soap bubble in the tool bag
@throttlebottle5906
Жыл бұрын
I agree on the not cleaning the trash out of the bottom and wouldn't have bothered to use coil cleaner either, now pulling the top and hosing from inside out with full/large stream up close(wont bend fins) and moved on. it's probably a splayed fin type coil and loves to plug bad deep inside where it's hard to see! granted it should have been cleaned yearly or more from install to keep efficiency up and to stop it from turning the gas/oil acidic, which could have helped the indoor coil to not leak for more years. BUT, it was likely indoor air contaminates and poor quality thin copper, which is also touching steel and aluminum and always wet when in operation... what could possibly go wrong? 🤣 far beyond us, upstream engineering/bean counter influence levels(total idiots at the helm) very few complaints from me on your service work(as well as others I watch and comment on), its all suggestions on possible improvements/easier ways. nobody is perfect (I know all too well), but some people out there just never try to improve and fail endlessly, also the ones that just keep running the system until frozen solid/burnt out fully. 🥳🥸