Thank you for your presentation, Kindly please showing us how to fix it as experiment
@greetec3158
4 жыл бұрын
Thank you sir good information
@Sd-uw9jb
Жыл бұрын
I have the same issue when the temperature reached more than 50 the AC will stop totally I brought some Technichen they said ot is matter of air recycling !
@MasterTomACElectronics
Жыл бұрын
It means your a/c wiill become high preasure thats why compressor stop. So the only thing you can do is flushing the system and change the capilliary and filter .
@carcanbus
3 жыл бұрын
thank you for explaining the error code. I have the same issue everything looks good. When compressor tripped on E1 which is high pressure the assumption pressure should be higher than 4.2 mpa however I checked the pressure on a Guage I installed it and found pressure is 300 which equal to 2.06 Mpa. is this clear indication that H. pressure switch is defective?
@taoobz4205
3 жыл бұрын
Hi dude i have the same problem what i do please
@MasterTomACElectronics
3 жыл бұрын
Yes sir if you encounter this e1 error if the unit run for few minute or hrs and before the error appear so probably your problem is in your system high pressure. But if the unit automatically e1 appear before compressor run so the problem is on our circuit board for hpp .
@taoobz4205
3 жыл бұрын
@@MasterTomACElectronics yes E1 appear after compreser run how much the price please
@MasterTomACElectronics
3 жыл бұрын
If you want change the pcb sir it's around 700riyals
@taoobz4205
3 жыл бұрын
@@MasterTomACElectronics thanks man
@fernansantiago294
4 жыл бұрын
Sir gandang gabi po...anung karaniwan n semi conductor ang pinapalitan sa outdoor pcb (fanmotor pcb control)e1 l error code kc high pressure n sya dahil po sa ayaw gumana ang outdoor fanmotor .. PALIT PCB KMI AT MAGING AYUS N LAHAT.. ANG NAIS KO SANA AY REPAIR KO dahil masyado mahal ang pcb (pwde po ba makahingi ng tips sir)
@MasterTomACElectronics
4 жыл бұрын
good evening sir karaniwan open resistor lng or yung photocoupler ang problema. so check mo llng yung resistor papunta ng photo baka open na cya.
@fredmma9550
2 жыл бұрын
What about e3
@mazheruddin8628
4 жыл бұрын
Please explain about p6 problem how to solve
@MasterTomACElectronics
4 жыл бұрын
Thanks for watching sir. Pls watch my another videothe title is Part 2 Training course at Gree Academy i mention there about P6 error...thanks
@fernansantiago294
4 жыл бұрын
Kabayan anu bng posible n sira kapag PU error code
@MasterTomACElectronics
4 жыл бұрын
Yung PFC sir sa drive PCB walang ma produce na DCbus kaya PU ang error baka cra na yung PFC IC mo and check mo din yung induction coil sa ilalim ng control box baka open na,
@fernansantiago294
4 жыл бұрын
@@MasterTomACElectronics salamat sir .. may isang customer n nmn aq ..PH ung sira..drive board (AP2 )posible ba ito ang sira sir???
@MasterTomACElectronics
4 жыл бұрын
@@fernansantiago294 Yes sir PH is DC Busbar over voltage protection.check mo muna sir AC supply mo baka mataas grid supply kaya nag high voltage ang drive board mo if normal naman ang grid supply mo possible problem ang drive board mo,