Agar es ko disbale kar day tao dg force mode may nahe hoga
@sarfrazmunir1478
Ай бұрын
Q nai hu ga ,,, 2 safety work ket rehi huti hain,,, ak oil senders ki ,,, aur dusri oil switch ki ,,, oil senders k pressure bar ko zero kiya ja sakta hai
@mechanicalengenering2678
13 күн бұрын
Sir plz failed to stop indication k bary may bato us ka kia hal kis tarh thek ho jayga
@sarfrazmunir1478
12 күн бұрын
Yeh video ko samj lain,,, ap ka masla hal hu jaye ga
@sarfrazmunir1478
12 күн бұрын
Ap kis country sy hain
@sarfrazmunir1478
12 күн бұрын
Us main mainy fuel ki relay ko short kiya hai ,,, js sy generator band huny ki bajaye fail to stop main chela jata ha
@mechanicalengenering2678
17 күн бұрын
Sir hamry pas same ye genrator hy jab hum usko stop karte hay wo stop nhi hota hay kia wajah hoskta hy
@sarfrazmunir1478
14 күн бұрын
Stop na huny ki beri waja us ko fuel aur air mil rehi hai ,,, aur module sy stop kra k check kern ,,, k fuel ki relay off hu rehi hai yah nae,,, fuel relay change ker k dekhay
@mechanicalengenering2678
13 күн бұрын
@@sarfrazmunir1478 sir may video banya hay hy uska wo apko kis tarah bejo
@sarfrazmunir1478
12 күн бұрын
@@mechanicalengenering2678 Ap apni fuel ki relay aur fuel pump k sath lagi hui fuel solinoid coil ki supply check kern,,, off button press huny k bad fuel pump k nechy lagi solinoid off hu ge you generator band hu ga
@sarfrazmunir1478
12 күн бұрын
@@mechanicalengenering2678 mainy dekh li hai ,, video
Пікірлер: 14