Thank you the only video I could find that shows simply how to programme it. Well done
@Brandywine-farm
5 жыл бұрын
THANK YOU!!!!!! Finally!!! a complete description!
@AdrianClement
3 жыл бұрын
Question? My inverter does not have a remote on and off, so in order to use it with my new Victron battery protect the instructions say I need a relay switch. Can you recommend the item I need? I have 1000 watt inverter and the 100 amp smart battery protect. Thank you in advance.
@jameshuynh5436
3 жыл бұрын
You should do the test so we can see it’s really disconnect when battery low volt
@bigmikestan
3 ай бұрын
Exactly I have the same one that he hooks up in the video 605 AM hook it up exactly the way he did in the video it never disconnected my batteries I sat here and watched them get down to 11.1 V and shut a cut off at 11.8
@ideasolar3601
2 жыл бұрын
Great Video, thank you
@kevinroberts781
5 жыл бұрын
Great item to have! May get one or 4!
@wimpiemare9822
Жыл бұрын
Good morning from South Africa. Can I use the 65 A model with two lead acid (100 ah) in my off-road trailer to protect the batteries?
@GarretTowneAMS
Жыл бұрын
Yes, as long as you don't plan on drawing more than 65A of load. The rating has nothing to do with the batteries, just the amount of load current.
@adamnov9542
2 жыл бұрын
Hello! my BP100, at a load of several watts it works well, but at a load of 20 watts or more, the inverter overload buzzer sounds. What is the reason for this work?
@sbssolutions3222
5 жыл бұрын
For those who are looking for more advanced low voltage cut-off please visit bed-electronics.com They have custom programmable units with nice user interface. Also these devices can hold inverse current as well. So charging a battery through them is not a problem.
@Brandywine-farm
5 жыл бұрын
That's the issue with Victron!!!
@sbssolutions3222
4 жыл бұрын
SBS6-32AL-240 and SBS 6-32PL-210 are capable 200A output.
@godblessthelessfortunate3175
3 жыл бұрын
You should upload videos to demonstrate your products. Otherwise, people are not going to buy them because they don't fully understand their capability and how to install and use them. I'm looking for a redundant overcharge protection between the battery and solar charge controller. There are already many products for redundant low voltage cut off protection but I haven't seen any for redundant overcharge protection.
@sbssolutions3222
3 жыл бұрын
@@godblessthelessfortunate3175 Thank you for your suggestion. For overcharge protection any bed-electronics universal LVD unit will do the job. Please look at this model bed-electronics.com/product/sbs6-32hb/ for example. You can contact me at info@bed-electronics.com if you need more info.
@joelvillanueva784
3 жыл бұрын
Good Morning. Can you please tell me what is the setting for a 24 volt VRLA Batteries using the 100 amp battery protect. Thank you.!!! Great video.
@GarretTowneAMS
3 жыл бұрын
I’m not familiar with those batteries, but for a 24V AGM we would do Shutdown at 24.2V and restart at 25.4V, Mode B. I hope this helps.
@alanpetersen4497
2 жыл бұрын
I have a system whereby the batteries supply 12V DC, in which a Victron BP would work to safe guard the low voltage discharge. However, when charging the batteries, the current flows in the opposite direction, to charge the batteries. How do you deal with this condition?
@GarretTowneAMS
2 жыл бұрын
Don’t go through the BP with your chargers. Have the BP only between the output and the battery. Normally, we put the BP between the battery bank and the DC fuse block. You would never put the BP on anything bi-directional, like an inverter/charger. If this doesn’t make sense, send me a wiring diagram and I’ll reply back with corrections garret@amsolar.com.
@richardowens9061
2 жыл бұрын
Can the Victron Battery Protect (220 amp) serve as a battery isolator? I have installed a 1000 watt inverter in the trunk of my 2021 Toyota Camry SE with a 1/0 gauge wire run to the starting battery, which is a typical lead acid battery. The negative terminal of the inverter is connected to ground. I also have a 100 amp-hour LiFePO4 battery located in the trunk also connected to the inverter through an Anderson SB50 connector cable using 4 gauge wire. While the engine is running, I want to be able to recharge the LiFePO4 battery. But, when the engine is not running, I want the starting battery to be disconnected, leaving only the LiFePO4 battery connected. So, will the 220 amp Victron Battery Protect device work for this purpose? Thanks!
@GarretTowneAMS
2 жыл бұрын
A Battery Protect wouldn’t be a good device for what you are wanting to accomplish. It might allow for too much current flow to your lithium battery and you might get backwards current flow from the lithium battery, which would ruin the BP. I recommend a Victron Orion 30A DC/DC charger instead.
@richardowens9061
2 жыл бұрын
@@GarretTowneAMS Thanks, for your reply!
@TheUnlocking
5 жыл бұрын
Hello there. Thanks for sharing the video. Do you happen to have information on how to parallel 24V 3000W Multiplus inverters, (2 of them) so the output is about 6000W?
@GarretTowneAMS
5 жыл бұрын
Obediah McMajor send me an email to garret@amsolar.com and I’ll get you some ideas.
@rynoopperman5010
2 жыл бұрын
Why did you set "B" for AGM what relay are you connecting...?
@GarretTowneAMS
2 жыл бұрын
“B” is mode the causes it to cut out at low voltage. We aren’t connecting to a relay. In this application, we are using the BP between the battery bank and the fuse block to prevent DC loads from overdrawing the battery bank.
@JustinCarver1981
2 жыл бұрын
@@GarretTowneAMS 8 is typical AGM setting, Ryno is correct the B setting is for relay. Your options are A for buzzer/led, B for remote relay, C for Li-Ion BMS, and d for system voltage detection.
@Travisj9935
2 жыл бұрын
So I want to run a voltage cutoff on my trailer battery. I have my usual 7 pin connector charging the battery. How would I tie this into that.. So the stuff I have running in the trailer off the battery down drag it down to far when not charging from the truck? 🤔
@GarretTowneAMS
2 жыл бұрын
To prevent your loads from drawing down your battery too deeply, put the BP between your loads and the battery, similar to how we have it in this kit: amsolar.com/rv-battery-accessories/98-dcdagm Make sure you select a unit that can handle the current you need. For example, don’t get a 65A BP and expect to run levelers. Also, make sure you don’t have a charging current going into the batteries through the BP. Current can only flow one way in a BP, not both.
@tedco-Theo
3 жыл бұрын
hELLO ! Please, is it necessary (and why) to put a "victron energy battery protect" 🙂😮😮 like I got a good BMS on my battery ? It seems to do a similar job, no ? Thank you. (perhaps have you got also a better idea. Thanks)
@GarretTowneAMS
3 жыл бұрын
It depends on your BMS. We like to put a BP between the battery and the DC loads. We like to make it shut off before the BMS shuts off, that we aren't relying on the BMS.
@tedco-Theo
3 жыл бұрын
@@GarretTowneAMS Ok ! Thank you very much !
@big5astra
2 жыл бұрын
When I put the jumper back in after programming I get an E 1 (error) message but its not like my 10A fuse is blowing on the input side of the Battery Protect so not sure where the short circuit is being detected (its an AGM battery). Any help on that? Thanks
@GarretTowneAMS
2 жыл бұрын
This is normal if there are any house loads on when the BP resets. To solve it turn the house loads off then turn the BP off then on.
@LittleRiverKingfiser
2 жыл бұрын
will this work with Renogy gel hybrid batteries 200ah?
@wordgirl8100
3 жыл бұрын
I'm preparing to build a lithium battery bank with plans to charge it from my auto alternator. I've already purchased the Victron 80 amp diode isolator. I'm now considering to purchase the Victron Battery Protect. With this set up, I'm thinking to place a fuse on the cable, near the battery bank, that runs from the isolator. My question is, can the Victron battery protect also serve as the on/off switch from the isolator? With regard to this wiring set up, Battery Protect included, would you say I would have my bases covered? What size Battery Protect would I need to purchase?
@garrettowne
3 жыл бұрын
Yes, you can cut power to the BP and it will stop current flow.
@V8LC100
2 жыл бұрын
Which model would be recommended for a 105ah lithium battery in a 4WD? I currently have a 0.14ah drain in my system that I want to isolate with the switch when I’m not in the car. How much does this Victron draw when in disconnected mode? Thx.
@GarretTowneAMS
2 жыл бұрын
If I used one, it would be between your battery and your DC loads. The rating depends on how much current you need to draw for the loads. The battery can probably put out 100A, so a BP100 would make sense, but people rarely need that much current, and typically use a BP65. If it is disconnected, it won’t draw anything.
@firpofutbol
5 жыл бұрын
Can the BP be controlled by a BMV 712? I want to be able to protect overcharge and overdischarge by disconnecting all loads and charge. Secondly, what happens if more current is fed than it is rated for, does it burn out and get damaged or does it disconnect load before getting damage. Lastly, is it installed only on positive side, is there ever a reason to install on negative side?
@GarretTowneAMS
5 жыл бұрын
firpofutbol One important thing to consider is that a BP is a MOSFET and you only want to install them in parts of a system where current will flow in one direction. If you send current the wrong way on a BP you will damage it. In other words, don’t expect one BP to handle loads and charging sources. Controlling a BP like a switch with the programmable relay on a BMV-712 is very common. A BP would be damaged if you ran too much current through it. Since electrons travel in loops, there is no reason you can’t install a correctly oriented BP on the negative side, but there’s no reason you would have to either. I recommend keeping with convention and putting them on the positive. It will make deciphering how your system works easier for any future owners. If you draw up a design and want a sanity check, email it to AM Solar.
@firpofutbol
5 жыл бұрын
@@GarretTowneAMS Thanks for your reply! How many devices can the BMV control? I'm thinking about using it to disconnect a BP for charging sources (Victron MPPT and Sterling battery to battery alternator charger), a BP for DC loads, and a non-victron (Samlex) inverter that has a remote on/off via a 12v signal. Can BMV disconnect also based on temperature and not just voltages when connecting its temp sensor to batteries?
@GarretTowneAMS
5 жыл бұрын
These are the same design issues we faced when we developed our V4 board. The BMV is only going to work for one function. Check out our website, go to Lithium Batteries and click on one of the Victron systems in the top row. If you look at the wiring diagrams you will see how our V4 board controls two BPs and a Cyrix for alternator charging. Also, check out our recent van videos. That rig used a V4 board.
@PaDutchRunner
5 жыл бұрын
firpofutbol This is why you would want to consider a Venus device, like the CCGX or the Venus GX. You can also run the Venus OS (distributed free of charge by Victron) on a raspberry pi.
@mowglie315
4 жыл бұрын
when charging with your alternator system aren't you worried about the alternator overheating due to lithium being able to consume a very high charge rate? also, it is bad for the eng alternator to be switched on and of many times correct? are there any systems in place to limit amps from the alternator in order to lower the heat of inverter [preventing damage?
@GarretTowneAMS
4 жыл бұрын
Mowglie This is a long conversation that would be easiest over email. In short, we typically use a Victron Cyrix-Li-ct. We don’t recommend it for low current or old alternators. The alternator isn’t connected and disconnected under load because that would damage the alternator. Send me an email with information on your rig and alternator and I’ll give you a recommendation. Garret@amsolar.com
@rabbitflow1
Жыл бұрын
can that be used for normal accid a battery how big battery could be ? i have two 12 v normal battery 180amp connecting to 24 volts system a ich battery is that will be good or i need bigger ?
@GarretTowneAMS
Жыл бұрын
It doesn't matter how big the battery bank is. You can use it on a 24V system.
@rabbitflow1
Жыл бұрын
@@GarretTowneAMS so where is dyfrent between 64A 100A and 220A?
@GarretTowneAMS
Жыл бұрын
@@rabbitflow1 The current rating, 65A, 100A, or 220A, has to do with how much current is allowed to pass through the device. For most DC Distribution systems we use the 65A. If someone has a DC air conditioner, we use the 220A.
@rabbitflow1
Жыл бұрын
@@GarretTowneAMS thank you so much I have air conditioning thank you
@Denver_place2001
6 жыл бұрын
what size wire can it be used on the remote switch on a sistem with max 30A load ?
@GarretTowneAMS
6 жыл бұрын
If I understand your question, we use 18ga to connect the two terminals of the remote switch. That portion of the system only needs continuity and doesn't have high current flowing through it.
@GarretTowneAMS
5 жыл бұрын
The part with 30A current would be 6ga.
@ek9772
3 жыл бұрын
If there is a Victron BMV-712 on the same system, would it have the same functionality as the battery protect with its built-in relay?
@garrettowne
3 жыл бұрын
You could program the BMV-712 relay to trigger a solenoid and that would give you similar functionality. But, the relay on the back of the BMV-712 is not designed for high current.
@ek9772
3 жыл бұрын
@@garrettowne thanks. I did not understand this before. For some reason, I thought the alarms on the BMV-712 could trigger a multi-disconnect function when either temperatures or voltages are out of sync.
@jarpen3
5 жыл бұрын
Hi is compatible with cyrix-xt
@meowzic
4 жыл бұрын
Could you use a battery protect replacing a BMS on lifepo4 prismatic batteries?
@GarretTowneAMS
4 жыл бұрын
Zack Vance unfortunately you need a lot more equipment for a BMS. A BP only allows current flow in one direction, it’s good for DC distribution, but you would still need cell balancing and controls for charging.
@ceeweedsl
5 жыл бұрын
I'm actually thinking of using one of these as a relay on the charging end from my alternator. Manage it with a BMV 702. Should be fine as long as amps are , right?
@GarretTowneAMS
5 жыл бұрын
I would recommend using a Victron Cryix instead. A BP is a MOSFET and should only be used to shut off current flowing in a single direction. With an alternator charging system, there is potential for current to flow both ways, which would damage the BP.
@ceeweedsl
5 жыл бұрын
@@GarretTowneAMS Thanks! That's exactly what I needed to know. I wish Victron made a Cyrix with unidirectional sensing. I already have one Cyrix Li-Ct in my system, but when the vehicle is off, it senses enough voltage off my Battle-Born Lithium to stay closed until the Lithium has been partially depleted by the Starter battery. Thus I use my BMV relay to open the Cyrix at low starter voltage. But I would also like to open the Cyrix at high SOC to avoid over-absorption. I am trying to figure out if I can get the relay logic to work with both parameters: [low starter V OR High SOC opens relay/ High Starter V AND Low SOC closes relay]. Otherwise, a second relay triggered by ignition on is an option.
@GarretTowneAMS
5 жыл бұрын
@@ceeweedsl Our experience is that the Cyrix-Li-Ct is only closed when there is a charging source on the battery. Do you have solar or a shore power charge elevating the voltage of the lithium battery? That might be way the Cyrix is closed.
@ceeweedsl
5 жыл бұрын
@@GarretTowneAMS Hmm...I now wonder if it's possible that I tested it with my portable panels out. Doubtful. That's a pretty big error and I really don't think so, but hey, stupidity happens! I am not near the van now so will have to check that next month. Been doing homework in the meantime to improve the system from last year's issues. Battleborn lists 99% charged as 13.4 and their tables show it would not hit the Li-CT's initial relay opening threshold of ...13.3V - until lithium drops to 90% charge. Have you not seen that in practice? Do they open right away after Starter battery drops or do they stay closed until the lithium drops to 13.3 after shutting down vehicle ? I need to do some more tests myself. It's only an issue when there's a full charge on the litihium and I only tested it once before deciding that I couldn't depend on the Cyrix Li-CT's voltage sensing and needed to rely solely on the BMS to manage it. I REALLY appreciate your informed input, Garret. Priceless. I will make sure to recommend and support AM Solar next purchase!
@GarretTowneAMS
5 жыл бұрын
@@ceeweedsl We haven't tested what you describe, but it isn't surprising, nor is it a problem, as long as you understand "that's just how it works" not "something must be broken." With this setup you aren't going to be able to keep your batteries at 100% without them gradually draining that top 10% into your starter. This isn't harmful for either battery bank. If you really need that extra 10%, know this ahead of time and plan your usable amp-hour capacity accordingly.
@SteveOfTheMountains
4 жыл бұрын
I'm confused, there's a lifepo4 model? I already got the 12/24 65 amp model Will this work with my 24 V lithium iron phosphate? Can you run through the settings and say what they are please?
@garrettowne
4 жыл бұрын
If I understand your question, there isn't a "LiFePO4 model", but rather different programming. Send me an email and I'll get you the settings. I don't know off the top of my head. garret@amsolar.com
@SteveOfTheMountains
3 жыл бұрын
@@garrettowne I have been goiing with the settings you show here.6b Works great on my AGM. Next I will try 8b with my calb LIFEPO4 set up. Thanks for ths video.
@surplusdoctor
2 жыл бұрын
what is the 220 for???
@GarretTowneAMS
2 жыл бұрын
Small inverters that don’t have a low voltage disconnect, DC air conditioners, etc.
@kogibankole
3 жыл бұрын
it wuold be nice it it said what voltage
@FlameRevenge
4 жыл бұрын
Hello how do I set up my Tesla battery with BP65 and BP220 to work with victron inverter charger?
@GarretTowneAMS
4 жыл бұрын
FlameRevenge With the current state of technology, we don’t think it works very well. Check out this article we wrote on the subject: amsolar.com/solar-panels-for-rv/2019/5/21/our-thoughts-on-tesla-battery-based-systems-for-rvs
@FlameRevenge
4 жыл бұрын
Garret Towne awesome thank you
@godblessthelessfortunate3175
3 жыл бұрын
@@GarretTowneAMS Link no longer works: "We couldn't find the page you were looking for. This is either because: There is an error in the URL entered into your web browser. Please check the URL and try again. The page you are looking for has been moved or deleted. You can return to our homepage by clicking here, or you can try searching for the content you are seeking by clicking here."
@GarretTowneAMS
3 жыл бұрын
@@godblessthelessfortunate3175 We restructured our website. Try this link: amsolar.com/blog/our-thoughts-on-tesla-battery-based-systems-for-rvs
@waldundteich
3 жыл бұрын
Great and Bluetooth connect?
@GarretTowneAMS
3 жыл бұрын
The Bluetooth makes programming way easier. This video was made before that was an option.
@waldundteich
3 жыл бұрын
@@GarretTowneAMS can jou bluetooth Video Produktion
@jameshuynh5436
3 жыл бұрын
You just show how to connect you should test it so we can trust that brand
@bigmikestan
3 ай бұрын
Exactly I used this product hooked it up exactly the way showed in the video and it never shut my batteries off. I sat here and watched them go to 11.1 volts should I cut them off at 11.8
@chrisjohnson1715
5 жыл бұрын
Why would I use 8B for my Li-Ion batteries over using C (Li-ion mode)?
@GarretTowneAMS
5 жыл бұрын
You'll have to elaborate on that. Send an email to AM Solar with more details on your system.
@chrisjohnson1715
5 жыл бұрын
@@GarretTowneAMS- I think i figured it out C mode Lionmode needs a BMS connected and it just acts as a relay and closes when the BMS tells it to disconnecting the load. Where as the 12v - 13v setting on 8B would monitor the voltage and disconnect if it goes below 12v. I have no idea what the lowest volage a LION battery should be allowed to go though....
@GarretTowneAMS
5 жыл бұрын
@@chrisjohnson1715 It depends on the battery, sometimes we go with 10.5V (2.625V/cell).
@ceeweedsl
5 жыл бұрын
@@chrisjohnson1715 I understand the LION is fairly depleted at 12.6V. These won't do that, but a BMS or BMV could be set to manage it.
@chrisjohnson1715
5 жыл бұрын
@@ceeweedsl I did some research and I ended up using 8B with a victron connect even though i do have a BMS system installed. 12v is fine for a LION battery and can discharge lower ( the only difference is they drop off fast at the bottom end unlike lead acid) so its perfectly safe to use 8B.
@deod.p9813
6 жыл бұрын
Can I use any one of BP between battery and inverter?
@garrettowne
6 жыл бұрын
Typically inverters automatically disconnect when the battery gets low, which means the BatteryProtect would be redundant. That being said, as long as the BatteryProtect current rating isn't exceeded, there is nothing wrong with doing it.
@GarretTowneAMS
5 жыл бұрын
Make sure your BP is rated for the current. A 1000W inverter can draw over 100A. Also, inverters typically have a low voltage cutout that would make the BP redundant.
@PaDutchRunner
5 жыл бұрын
Also, you would never want to place a mosfet device like the BP in a place on your system where you anticipate two-way current, e.q., between battery and an inverter/charger. A mosfet can accommodate one way traffic only and subjecting it to reverse current is a very serious fire hazard.
@PaDutchRunner
5 жыл бұрын
Also, you would never want to place a mosfet device like the BP in a place on your system where you anticipate two-way current, e.q., between battery and an inverter/charger. A mosfet can accommodate one way traffic only and subjecting it to reverse current is a very serious fire hazard.
@carl8568
2 жыл бұрын
@@PaDutchRunner So where in the system does it go?
@geelee1977
2 жыл бұрын
Do you have to have a shunt? What does a shunt do and why do you need it? Sorry, total newb. Hope someone takes pity on me lol
@GarretTowneAMS
2 жыл бұрын
The shunt is a resistive device that goes in-line with the battery bank. Think of it as an electron counter, that measures everything going in or out of your battery. This measurement is used to calculate the battery bank charge level. Another method for determining that state of charge is a voltage meter, but this isn’t nearly as accurate, and doesn’t work with lithium batteries. So, if you want accurate battery monitoring, get a shunt-based battery monitor.
@geelee1977
2 жыл бұрын
@@GarretTowneAMS Thank you!
@EcoNeato
4 жыл бұрын
Terrible videographer
@Medycarbo
3 жыл бұрын
hi, I've got a BP 65 like the one in the video. I am looking for the setting for lead acid batteries. which one should I program in Your opinion?
@GarretTowneAMS
3 жыл бұрын
Enter the following values: Shut down: 12.1V, Restart: 12.7V, Leave on mode “B”