With exception as noted here, pretty good video. Horrible conduit install from panel to panel. Violation 1. Because the bar you used as ground on the right is insulated from the panel can, the bonding jumper shown unconnected must be turned and connected to the ground bar. Violation 2. Respectfully, Kevin
@pauldonovan7724
2 жыл бұрын
Very, very useful and a concise and articulate video. Really makes the point about how easy this is if you are careful.
@vdubing01
3 жыл бұрын
Thank you SO much for a clear and simple how to. My panel is full and I need more baskets. This just answered so many problems for me.
@timothyneville7036
2 жыл бұрын
Very important that nuetrals go on the insulated terminal strip and ground wire always goes on the bar common to the can
@nunyabizznuss8463
5 жыл бұрын
Thanks, concise and to the point without a whole bunch of technical jargon because you assume people already have some common sense when doing this type of work.
@ItsAlive111
3 жыл бұрын
Aren’t these wires too small to transfer power from one box to another? I’d assume for a 50amp breaker you would need 6AWG wires
@johncuda
3 жыл бұрын
Are you able to add a 220 breaker to the sub panel? Does it depend on the breaker you use on the main panel to transfer power? Thank you.
@alcolavista-22
6 жыл бұрын
Nice presentation it’s a 5 star.. 👌same as my 125amp adding onother kitchen area.. 60 amp panel is a simple good sub panel for garage work shop or onother kitchen..
@tedlahm5740
5 жыл бұрын
Bonding screw removal in the sub panel?
@rofotheman2230
9 ай бұрын
Very well explained…thank you for this
@archer9732
Жыл бұрын
Would have been nice if you showed us the conduit fittings between the boxes.
@odie2100
4 жыл бұрын
Great Video All questions answered and addressed in your video..I give it👍👍 and ⭐⭐⭐⭐⭐!!
@jonp6347
3 жыл бұрын
What is the maximum Amp on the main panel can you use. Thanks for the video..
@Matt-ng1fy
3 жыл бұрын
You can buy double breakers that 2 take up the space as one essentially has the potential to double your breaker amount
@ryanwashenesky5044
3 жыл бұрын
Not all boxes accept half size breakers. My ge 2010 box wont.
@Matt-ng1fy
3 жыл бұрын
@@ryanwashenesky5044 duh but some people don't know about the 2 breaker option. And it's actually a single slot breaker, just with 2 instead of 1.
@heroknaderi
4 жыл бұрын
I appreciate your video I have a split bus panel that’s full and using your trick 😎🤩👍 by moving one of the 6 breakers in the upper bus and move it into the sub panel will be supplied wy100 amps to expand on😎🤩🤩
@ItsAlive111
3 жыл бұрын
If you had to move another breaker from the main panel to the sub panel, do you have to move the neutral and ground from that circuit associated with the hot line of that breaker to the new sub panel?
@Djm9393
3 жыл бұрын
Just curious why did you use a 60amp breaker instead of 100amp or 50 amp?
@moneyRalf212
Жыл бұрын
Because one box is feeding the other and it cant give out higher amp (110) than it is receiving.
@moneyRalf212
Жыл бұрын
Because one box is feeding the other and it cant give out higher amp (100) than it is receiving. Basically sharing the amp thats already in the first box.
@rbrooke2379
3 жыл бұрын
Excellent, thorough and clear.
@rh5971
4 жыл бұрын
Well done and very well explained.
@3AholesMedia
3 жыл бұрын
Thank you Jeff Goldblum, very helpful
@dvmartel1
Жыл бұрын
Jumper wire between the two "halfs" and you can use either side of the bars.....
@skiball2000
4 жыл бұрын
Is it possible to install two separate sub panels. The first would travel 115 ft Tony current camper that uses 30 Amp breaker and be ready to upgrade to my future 50 amp breaker. Plus a flood light and a small 20 amp outlet. My second sub panel will power my soon to be finished basement. My ham radio room will be on separate breakers just for my expensive equipment and radios. The rest will power the basement living room shower area , kitchen, etc. I plan common ground straps where my antenna grounding will also connect with multiple grounding rods spread apart according to code. Sorry for the long rambling and thank you for reading. Can if you can, please give me sound, useful, helpful Critiques. Keep in mind please, I’m asking because I’m trying to learn. My level of understanding may be far below yours. Thank you for understanding and have a wonder day. ❤️❤️❤️
@scottdebanto3697
4 жыл бұрын
I like the video, very informative and easy to understand. I have a 30 amp breaker on the main 200 amp service panel that I want to use as a secondary circuit breaker box or sub-panel. The breaker has three wires, the black, white and ground. Your video includes a red wire. Do you know if I can add the sub panel with this only a three wire (black, white, ground) configuration? Thanks.
@thomasmarable6818
4 жыл бұрын
No you can't.
@tinajones4316
Жыл бұрын
Good job my man easy explain ln
@jimxiong3815
2 жыл бұрын
I love wires thanks for this video
@alecplasencia7667
2 жыл бұрын
What year was the building built im just curious how old and what year that challenger electrical panel you have
@stevenderusha6421
3 жыл бұрын
Wouldn't you overload your 200 amp panel?
@cesar68033
7 жыл бұрын
What size wire did u use to connect the boxes together
@jeremychapman1976
7 жыл бұрын
He used 6 AWG which is good up to 55 amps.
@adamwise1790
6 жыл бұрын
6gauge isn’t very big try 500 or 750 mcm 100 and 200 ampseasy compared to that lol
@HotRodRob427
9 ай бұрын
Great Video!!!!😊
@kelwinf
3 жыл бұрын
Very helpful. Thanks!
@pcobra3
6 жыл бұрын
The grounding buss needs to be grounded to the panel!
@aaronhysom8096
2 жыл бұрын
Why did you use two breakers to feed the panel? In theory you would only need one breaker to feed the buss of the sub panel? Thx
@pvmsupra9607
2 жыл бұрын
240v connection requires 2 hots like in this set up. Double pull switch breaker requires the space of two breakers. It's basically required to get all 240v over to the sub panel
@brstilson
4 жыл бұрын
Don't you need bigger wires? Those don't look any bigger than #10 wire but that's not nearly rated for 60 amps.
@jak712we
2 жыл бұрын
Wow what a easy job, the electrician charge me 1300$ USD to add the extra panel and two extra barker. I feel like I got robbed.
@Ron-dr6iw
3 жыл бұрын
You don’t need to add a sub panel, all you needed was space saver breakers. The space saver breakers is two breakers that takes up one breaker spot.
@AJ-we9kd
3 жыл бұрын
Aren’t those space savers a bit tricky for breakers on 2 or 3 pole supplies with Y or Z configurations?
@juanjc1951
6 жыл бұрын
Where did you get those spacer you put between both services panel to put the wire through
@TheBirdandEagle
5 жыл бұрын
Excellent video. Thank you.
@joshuacassino7297
3 жыл бұрын
My sub panel looks to be powered by 40amps. Can I install a 60amp breaker along with the 15 and 30 currently in there? There’s 4 empty spots.
@wtorres562
Жыл бұрын
I see that you put the subpage upside down.
@LightWalker03
7 ай бұрын
Thank you
@danlacy4588
5 жыл бұрын
What gauge wire should be used for the 60 amp to sub panel?
@Nick-bh1fy
5 жыл бұрын
4awg
@danlacy4588
5 жыл бұрын
@@Nick-bh1fy thank you
@Kingkilla0127
3 жыл бұрын
Shouldn’t he have grounded the panel with the existing one too where the green screw is at?
@devanmills4640
2 жыл бұрын
You don’t bond sub panels per code
@xfishman123
5 жыл бұрын
Id change out that old challenger box.
@smichelsen
4 жыл бұрын
I notice that the bar to attach the grounds is isolated from the box, rather than bolted directly to it. Is there an advantage one way or the other?
@thomasmarable6818
4 жыл бұрын
By code it should be attached to the box. The way he has it there is no path for fault current so the box can become energized. So yes it should be connected to the box.
@sinclairnomis4060
4 жыл бұрын
Did you do this with 200 amp service
@suespony
2 жыл бұрын
Looks like it's a 100 amp main breaker, I was trying to see that also, pretty sure it's a 100
@Jon_Crawford
6 жыл бұрын
Hey folks watching this please don’t take this guys advice. He said a couple things that are not right in video and plus he doesn’t even have his ground bar in sub bonded to the case. He shouldn’t be doing this work.
@Keystone_Back_Forty
5 жыл бұрын
to late... I've already published a book using his instruction and sold it every apprentice and tech school in the country.
@Chakirisan
5 жыл бұрын
Jon, do you need to run a ground and neutral between the buss bars from main to sub (Assuming new ground bar is attached to case which is the first thing I changed) or can you attach white and copper coming off 4 wire only to new panel. Thanks!
@billymurphy2748
4 жыл бұрын
I agree 💯 with there
@jean-pierredoucet8328
Жыл бұрын
I thought you don't bond a sub panel box
@VacMaster2020
Жыл бұрын
@@jean-pierredoucet8328 you’re not supposed to bond your grounds and neutrals in a sub panel you’re supposed to separate them like he did
@warrenmichael918
7 жыл бұрын
not gonna address the ground bar in your sub panel that isnt bonded to the case ? The plastic legs its on and the ground leg that isnt attatched ?
@FiguringItOut1
7 жыл бұрын
Thanks. Yes the green screw holding the "z" bar in the sub panel gets mounted next to and connected to the ground bar to bond the ground bar to the case. Thanks for pointing that out.
@warrenmichael918
7 жыл бұрын
I wasnt trying to sound like my post read, i was just wondering if it was something that wasnt addressed in the video. LOL , i was just in that goofy youtube place late one night where i was stuck watching videos of different things that were not related and kept getting deeper and deeper. I finally snapped back to reality and went to bed when i found myself watching a video of an old lady wearing scuba gear and high heels changing the oil on a push mower on her kitchen table !!
@peterdeyoung5160
6 жыл бұрын
Figuring It Out in the sub panel the neutrals do not get bonded together. So grounds should be separated from the neutrals
@tjwoolsey478
11 ай бұрын
Get a tripod for god sakes
@nathanr.8556
2 жыл бұрын
Terrible code violations
@EcoNeato
Жыл бұрын
Terrible annoying audio and very difficult to follow this