Sir 220 v wali motor ko meggar se kitnay voltage pay check karay gai
@excellentelectricalknowled6672
Жыл бұрын
Thanks for asking the question sir🙏 Sir 220 volt operated motor ko magger se 250V applied karke karana chahiye.... But sir if aap ke pass magger me 250v range nahi hai to aap 500v applied karke kar sakte hai.... Jab aap 250v applied karke magger karenge to IR Value adhik aayegi... Jab aap 500v applied karke karenge to IR Value Kam aayegi ...
@excellentelectricalknowled6672
Жыл бұрын
Applied voltage ke according IR Value bhi change hoga....
@ganeshmore6566
Жыл бұрын
Thank you sir
@excellentelectricalknowled6672
Жыл бұрын
Welcome
@shehbazmansuri
Жыл бұрын
Sir kitne mega ohms tak motor chalana safe hota hai jaise reading winding to grd aya 2mega ohms to kya woh safe hai
@excellentelectricalknowled6672
Жыл бұрын
Below 1kv 5mega ohm(minimum Hona Chahiye safe working ke liye) lekin yadi yadi 5 mega ohm SE Kam AATA hai aur motor KO chalana jaruri hi hai to ,,under observation me motor KO rakhana padega...
@irshadalam-ec7ur
Жыл бұрын
Super
@gamez.0312
Жыл бұрын
Motor pm kaise kiya jata hai is par video banayen
@excellentelectricalknowled6672
Жыл бұрын
Okay dear
@electricaltechnicianingulf5299
2 жыл бұрын
Superb video bhai AYTB COMPANY me ho aap me Saudi. Me kam kartahu mere sath bi AYTB ke technician kam karte he aap konsi compny me ho
@excellentelectricalknowled6672
2 жыл бұрын
Aytb Jubel
@electricaltechnicianingulf5299
2 жыл бұрын
@@excellentelectricalknowled6672 me bi jubail me hi hu
@vipulrai661
Жыл бұрын
Very very good sir
@excellentelectricalknowled6672
Жыл бұрын
Thanks dear ❤️❤️
@RamveerSingh-ws4tx
Жыл бұрын
👍👍👍👍👍
@bijupalliyil1586
2 жыл бұрын
👍🏻
@khokherbaldeep
Ай бұрын
Please mention the Megger Model
@mdnujalam3268
2 жыл бұрын
Nice information
@excellentelectricalknowled6672
Жыл бұрын
Thanks
@mdnujalam3268
2 жыл бұрын
Bhaiya cable meggar karte samaye kitna resistance ana chahiye thoda bataye ek video banaye cable ka megring kaise hota hai kitna tak ayega to sahi hai
@girishjoshi4874
2 жыл бұрын
100 + mega ohm
@excellentelectricalknowled6672
Жыл бұрын
thanks
@veerkumar3452
Жыл бұрын
Three phase induction motor ki minimum ir value kitne honi chahiye jis ir value ko safe mankar us ir value par motor ko run karwaya ja sake.please explain sath hi yeh bhi batayen ki kisi bhi ya 16 sqmm ki three core ki cables ki minimum ir value kitne honi chahiye jisko safe ir value mankar uus three core cable ko use kar sakte hai please explain
@excellentelectricalknowled6672
Жыл бұрын
Ok ...chanel par motor ki minima. Ir value se related vedios hai...
@mohanrathod1792
Жыл бұрын
IR value 5 Megha ohm se jadha nahi Anna he
@Azammallickjamui
Жыл бұрын
Bhai panel se ir kaise check kre
@excellentelectricalknowled6672
Жыл бұрын
Dear panel se breaker KO off (isolate) karke( R phase to ground) (Y phase to ground) (B phase to ground) Karate hai.... If Kisi phases to ground ke between IR kam Aaye to... Ab yah confirm karna padega kaun si winding me problems hai...it means (U1-U2) (V1-V2) (W1-W2) Tab Motor side Jake terminal box open karke connection star ho ya delta Sabhi terminal KO alag karke each winding to ground check karke confirm Kiya jata hai kaun si winding me problems hai... Dear if Aapka answer Sahi large to reply jarur kare...
@Azammallickjamui
Жыл бұрын
Yes bro usefull answer
@excellentelectricalknowled6672
Жыл бұрын
Thanks
@ravindrabhaipatel4453
Жыл бұрын
Tumhri to field to feild value a rhi h Eshka mtlb motor kharab h I mean moter insulation kharab ho gya h
@excellentelectricalknowled6672
Жыл бұрын
Dear, Value zero(0) aayegi, I means field to field aapas me short hai.... field to field value aane ka matlab 1st field ke upar Jo insulation rahta hai, same 2nd field ke upar bhi insulation rahta hai, to in dono fieldo ke insulation ke karan jo resistance ka value hota hai. Usi ko to magger se voltage applied karke check kar lete hai...to jitani maximum value aayegi it means utana hi best hai...
@excellentelectricalknowled6672
Жыл бұрын
Dear, same jab winding aur motor body ke bich ir test karte hai, actually winding ke upar chadhe hue insulation and varnish ke Karan Jo insulation winding ke upar Chadha jata hai, to Magar testing se motor ki body and winding ke bich insulation ke Karan Jo i r value aata hai usi se to ham nirdharit karte Hain, physically winding body se to connect nahin Hoti, same condition jab ham binding to winding IR test karte Hain use condition mein bhi ek winding dusri winding se connect nahin Hoti to Ir value aaega hi Na...
@nitinkumarawana95
Жыл бұрын
Apka contact no dijiye
@excellentelectricalknowled6672
Жыл бұрын
Wattsapp 9167386808
@itielectricalclasses201
Жыл бұрын
V2 and w2 ir value coil to coil is not same other 2 winding
@excellentelectricalknowled6672
Жыл бұрын
ir value different.no issues
@ravindrabhaipatel4453
Жыл бұрын
Fild to field 0 honi chahiye
@ravindrabhaipatel4453
Жыл бұрын
Ye to velue kyu a rhi h
@ravindrabhaipatel4453
Жыл бұрын
Fej to fej 0 hota hbbhai
@hazratshahshahnawazkhan563
Жыл бұрын
Sorry . You check continuity not resistance
@excellentelectricalknowled6672
Жыл бұрын
Sir, I.R. test karne ka details process hai..
@160c82d
5 ай бұрын
Incomplete information.
@excellentelectricalknowled6672
5 ай бұрын
Thank you for your suggestions....ek hi videos me sabkuchh batana possible Nahi ho pata ....log lambi video Kam dekhana Pasand karte hai.....
Пікірлер: 55