Hi Mark , I used to check lead resistance ( total resistance from the CT passing to a ammmeter to kwhmeter) using a bigger wire size will not effects the CT ratio. I agree with your remedy. CT burden used to know this things. In power metering compensate by using bigger wire to avoid votage drop.☝️
@juliofonseca9091
11 күн бұрын
Buenos días mi pregunta es como puedo comprar el CT Solis original en que parte se consigue saludos desde Nicaragua américa central agracia por tu tiempo
@paweldedys9033
3 ай бұрын
Hi do you know what is called plug that go in to Solis inverter socket for CT clamp port? Thanks
@MarkMinoza
3 ай бұрын
thats a good question. ill try to ask them.
@davide1881
Жыл бұрын
Hi Mark. I have a distance problem. my inverter is placed on the 6th floor and the load and the grid is about 25 meters away. can I move the meter directly and lengthen the 485? thank you
@MarkMinoza
Жыл бұрын
Thats too long, you still can but youll have problems in delay. That’s why Solis has meter type GTi, that eliminates the extension from CT to Inverter. Inverter to meter can be as long as 50m, but meter to CT should only ne 3M.
@KoRWraith
Жыл бұрын
Hi Mark, I have an existing EV charger with a CT cable running to the consumer unit. I'm planning to install battery storage with a Solis inverter near to the EV charger. Is it possible to use the same CT cable for both the EV charger and the Solis inverter? i.e. could I cut into the CT cable and put each wire into individual 3-way wago connectors, then run to both EV charger and inverter? Alternatively, is there such a device that could duplicate the CT cable to two outputs? I ask because it would save me lifting up the floorboards to run a second CT cable for the inverter.
@MarkMinoza
Жыл бұрын
I don't think ti would work. Unless you have a device that reads after the ct connection that send data to both eV and gti hardware. But splitting its connection, haven't done so. Better an external meter like Eastron (Solis uses it also) and feed the output to your hardware.
@carlocastorvlogs1748
Жыл бұрын
Sir how to know if the ct lim is working or not, ct link is on cant judge thank
@MarkMinoza
Жыл бұрын
Load power should be higher than 500w, if the ct link still “cant be judge” have it returned to your seller. They’ll test it for you. CT Lino Test is only applicable to CT type Solis GTi. Meter type doesnt have one.
@ea_bal
2 жыл бұрын
Boss, san ka nakabili ng Wago connector?
@MarkMinoza
2 жыл бұрын
online sir. rs-online ko nabili ang Wago connectors.
@akubaikbaiksaja6097
Жыл бұрын
What the name conector. I want to buy conector only
@MarkMinoza
Жыл бұрын
which specific connecter are you asking ? Wago is available on rs-online shops.
@huplim
Жыл бұрын
He is referring to the connector to the inverter
@MarkMinoza
Жыл бұрын
@@huplim its included when you buy a Solis Inverter or any brand for that matter.