They are too close together, have to think about future repairs and replacement.
@jerseyshoredrainagesolutions
Жыл бұрын
True
@alexsalazar1569
Жыл бұрын
I think he was trying to make a duplicate of the original orbit multi valve manifold. In the original they are this close and IF im not mistaken (dont quote me on it) i believe its also a one piece meaning if something breaks, gatta replace the whole manifold. But wouldn’t be a bad idea to leave about 2in in between each T just incase you need to replace something you’ll still have two inches to add a new T and but glue it all up
@johns5127
Жыл бұрын
Those are Jar tops and can be rebuilt. Still should use manifold fittings but nobody I’ve ever seen on the KZitem rors
@timsanders3857
Ай бұрын
remove the top and spin them off.
@CJINW
Жыл бұрын
States properly, prime & glue, however, he does not prime. I know the rain and shine does not technically need priming however, still is a good idea for lines under pressure.
@jerseyshoredrainagesolutions
Жыл бұрын
This is true
@DoodleyDavid
Жыл бұрын
You must of missed the end when he uses clear proper.
@Metaldetectingwithchris
11 ай бұрын
I put primer on there @cjinw 🤌🏻
@Z0mbiekiller82
Жыл бұрын
They sell pre molded manifolds in 2, 3, and so on. You can also add on to them. Saves a lot of time and if you need to change a valve later you just unscrew it at the union and screw another one in. Check your local nursery sprinkler shop. Not going to find them at a big box store other then orbit.
@jerseyshoredrainagesolutions
Жыл бұрын
Thanks
@donhgr
4 ай бұрын
Why no unions for filter repairs?
@artymunoz5060
Жыл бұрын
“This is how you properly put a manifold together” *manifold already installed*
@jerseyshoredrainagesolutions
Жыл бұрын
Lol
@DogFacePuffa
2 жыл бұрын
Are valve boxes typically a standard size for 1, 2, 3 valves? Why not add PVC unions for quick swap out?
@jerseyshoredrainagesolutions
2 жыл бұрын
yes up to 4 valves
@AlexRodriguez-hi1rq
Ай бұрын
Necesita 3" de separación.
@evanbrandt1144
2 ай бұрын
Space it out further to be able to replace in the futuee
@danbutler7586
Жыл бұрын
Why are they all so close together, is there room to unscrew the valve assembly?
@franciscovalencia-n3i
Жыл бұрын
always leave a little bit of lead between valves for future repairs atleast 5 inches
@uncleronny6748
5 ай бұрын
Action Machining manifold por favor.
@TRDjuli
11 ай бұрын
I've been doing sprinkler pretty much all my life I'm 22 now started when I was 10 changing sprinkler heads. I rarely put primer only when I have inspection. Just glue on pvc will not bust if you leave it to dry for a bit.
@jerseyshoredrainagesolutions
11 ай бұрын
Thanks for the tip
@jimrylander9143
Жыл бұрын
What are you using for backflow protection?
@heroknaderi
Жыл бұрын
That is solid advice boss thank you 😎😎
@jerseyshoredrainagesolutions
Жыл бұрын
Thanks
@jwagner1993
3 ай бұрын
I hate PVC manifolds. Every time I spot one bad valve with a PVC manifold I always charge to replace everything
@reAllyNoWayyy
Жыл бұрын
No schedule 80 for the manifold? Or gray heavy bodied glue?
@jerseyshoredrainagesolutions
Жыл бұрын
The ex partner said he knew what he was doing lol 😆
@reAllyNoWayyy
Жыл бұрын
@@jerseyshoredrainagesolutions not knocking at all, I mean hey if it doesn’t leak that’s great. But definitely should use schedule 80, purple primer, gray heavy bodied glue, add longer nipples between the valves and tee fittings (at least), blue Teflon is usually thicker than white Teflon - use white Teflon it is less stress on the connections. Judging from the blue Teflon, the guy was a plumber. I’ve worked with a plumber doing irrigation, let’s just say he had his ideas and I had mine 🙄
@jerseyshoredrainagesolutions
Жыл бұрын
@@reAllyNoWayyy I heard that 😆
@jrocc209
Жыл бұрын
Could be 40c which is a stronger 40
@PaulNielan
4 ай бұрын
Dirt, mud, existing vegetation, roots, hills, wiring, debugging
@frank-gf5vh
3 ай бұрын
Avoid a headache by installing a ball valve before all valves.
@zaloalvarez6947
2 жыл бұрын
Can i just hook up the sprinklers to a water faucet outside?
@jerseyshoredrainagesolutions
2 жыл бұрын
They do have those types of timers. But you would also need the lines up to connect to them. And depending on how many zones you have and pressure… they may not work efficiently
@Frenojan007rr
Жыл бұрын
Do you need a pump for those valves or can you just use those electric valves with the home utility water using non-pump?? Please help
@jerseyshoredrainagesolutions
Жыл бұрын
Electric valves with home utility water
@adamcoffee738
3 ай бұрын
Yeah no, how do you change the valves if you ever need to with the way you have done it
@jeffspires3800
2 ай бұрын
Pleases don't do this as a professional for 39 years. Manifold ING is all great for ease but if 1 of your mainline tees break, it's a nightmare to repair. Better of locating valve in the center of the zone, system will also work better without the friction loss
@sprinklersrepairlandscape
Жыл бұрын
I recommend to leave some space between each other just for future repairs 🥂
@jerseyshoredrainagesolutions
Жыл бұрын
True
@Bankroll98
3 ай бұрын
You don’t need to prime new pipe
@carsonp3389
Ай бұрын
No space between the tee’s. Your company motto must be “fuck the next guy”
@jonathancasillas-serrano3102
Жыл бұрын
The language in this video is slightly misleading cause there is unknown false information by the creator. Says "once its togther thats it" "replace the entire manifold" this is the unknown false information. Heating the pvc at the connection will allow the tubing to be removed and if done right (again very easy) you will not damage the connections and be able to reused everything besides the pvc tubing.
@Sinder_Primagen
9 ай бұрын
PVC cement and Primer
@vishyandypurandat6208
Жыл бұрын
How do you take the valve off it you have to replace the valve.😊
@jerseyshoredrainagesolutions
Жыл бұрын
You unscrew it
@vishyandypurandat6208
Жыл бұрын
@@jerseyshoredrainagesolutions DO a video with the same mockup let's see.
@billhoffman252
3 ай бұрын
Just change out the guts
@anonymous..-
3 ай бұрын
Ha. This guy probably also shoves them in the smallest enclosure possible.
@hectormoreno3837
3 ай бұрын
To close for future repairs
@PrimroseIrrigation
4 ай бұрын
DV 100 is a much better valve.
@herndz1088
2 жыл бұрын
That’s not how you put manifolds together …
@eiknarfzepol
Жыл бұрын
I don't know.. no room to fix down the road...they will leak... to close together...
@jerseyshoredrainagesolutions
Жыл бұрын
They worked
@jerseyshoredrainagesolutions
Жыл бұрын
Good point
@dalton1462
15 күн бұрын
Wrong use reams manifolds
@jordanhunter9765
4 ай бұрын
Must've ran out of unions 😂
@israelreyes51
Жыл бұрын
Until u need to change a crack valve you will spend more on repairs
@JohnnyD1993
Жыл бұрын
Please do not use thread tape on plastic threads.
@fatihdemir9978
Жыл бұрын
Slop job even if it’s going to be buried
@kairu.kun.z
2 ай бұрын
Or just use one step 😂
@Ozaiyah
Жыл бұрын
DIYers
@senorex2088
13 күн бұрын
the pressure from your house will blow these apart?? 😂😂😂 valves can handle 150 psi what kind of pressure does this man have inside his house. too many idiots with courage to be posting online.
@jerseyshoredrainagesolutions
5 күн бұрын
Lol.
@BramBiesiekierski
17 күн бұрын
Really shitty way of doing it. You can buy manifolds for probably less than you spent on fittings and glue. The advantage of the manifolds is they have tube nuts that are free to rotate. So you can easily unscrew the solenoid.
@blakebrinson7429
Ай бұрын
Please don’t try to teach people your horrible technique
Пікірлер: 70