One thing that they forgot to add. A relay for electric strikes and electric latch retraction exit devices. That's a problem because, in my building, the restroom door is fire rated. So, it uses a lockset. So, I will have to use an electric strike on my restroom door. This device doesn't have a relay for an electric strike. I hope LCN has a solution for doors that have latch bolts and electric strikes.
@JLD902
Жыл бұрын
Technically you can use this device with a strike, relay and option board would have to be added and strike powered by it‘s own power supply as this operator only has a power out for the BEA 900 receiver supplied with it,
@Stye-nz2zi
Жыл бұрын
Will this actuate upon manual open of the door? I.E. pulling or pushing open the door?
@JLD902
Жыл бұрын
Hello Stye, sadly no this device does not support “push-N-go”, the devices that do are usually high energy operators that do not use a door closer as part of their functionality, the 6400 is a low energy operator and can only be triggered by a wall button/wave switch to operate, LEO’s can only have “knowing act” switches, “Push-N-Go” is not knowing act compliant Hope this helps understand the world of Low Energy vs. high energy operators -Jess the door closer doctor
@18rmiller18
2 жыл бұрын
does this comply with ANSI?
@LCNHardware
2 жыл бұрын
Thank you for your question. This product is certified to ANSI 156.19.
@rc846
Жыл бұрын
Don't you just like it when the ceiling is o" above the frame? I wish architects would consult more.