You've forgot your earth leakage bucket to catch it
@Aterhallsam
10 ай бұрын
For how long can you leak earth and what do you do when ur out of earth
@davey2k12
10 ай бұрын
Fall down the hole 😂😂😂😂
@samgriffiths7609
8 ай бұрын
10 minutes. All of your appliances will explode.
@ln8605
8 ай бұрын
We reduce earth leakage as it makes the earth 🌍 get smaller. This is why house prices are so expensive as the UK has lots of leakage, making our land mass smaller, 30mA every 300mS
@Aeyer100
7 ай бұрын
@@ln8605😂😂
@kres01
8 ай бұрын
I think your are supposed to turn it on first... Zero it out and then clamp it around the wire. Your measurement isn't correct if you don't get the orde right..
@AndyK.1
10 ай бұрын
Interesting to see what was on the cpc and bonding
@simbamuseka4028
10 ай бұрын
😮
@tomorichard
9 ай бұрын
I would imagine 8.4mA
@samgriffiths7609
8 ай бұрын
Great bit of kit but do yourself a favour and get a megger one! Larger aperture and out of the 2 tis voltmeters I’ve had in the past, both claimed continuity when there wasn’t any! Was going spare trying to find a fault that didn’t exist 😵💫😂
@Wroe
7 ай бұрын
RCD's generally trip at a max of 30ma schools use 10ma your using rhis for fault finding
@antoniogalluccio4213
7 ай бұрын
Please make the pther video. If it's therw apready please send the link
@rafaelportella5059
10 ай бұрын
Como assim??? Medir dois cabos juntos????
@crashcamchronicles
4 ай бұрын
Yes When you clamp, ac in and ac out cancel each other em induction. If ac in is bigger than ac out you’ve got leakage somewhere. That’s current going to earth rather than back the neutral.
@NathanBaldini-cy2rn
7 ай бұрын
Why
@herrtomas6729
10 ай бұрын
Need to point out that the earth leakage tester is specific for the job - not all clamp meters do this; need a dedicated type. Mine was about £40 from CPC Yes, important and useful.
@jessewilliams6459
9 ай бұрын
Why?
@thomassheridan4252
9 ай бұрын
What do you do to stop this if reading is to high
@ln8605
8 ай бұрын
Check each circuit by putting around the live and neutral to localise
@brettuk
9 ай бұрын
how come u clamp the tails and not the earth? that's the bit i don't get !
@jonathanireland2913
9 ай бұрын
To measure the difference in current between L and N, which will be leaked to Ground. As a side note, remember the 30% rule for Residual devices on a new install; Should have no more than 9mA of leakage on a 30mA device and so on... Also a 30mA RCD will generally trip around 19~21mA, hence some testers don't measure above 20mA.
@tazerpie
8 ай бұрын
My man. An imbalance between phase and neutral means it’s NOT leaking to ground… if it was leaking you’d have zero imbalance, and you’d be looking to measure on the earth wire
@fieldsofomagh
10 ай бұрын
Where do I purchase this meter ?
@jimbotheelectrician3819
10 ай бұрын
Wholesalers or toolstation
@herrtomas6729
10 ай бұрын
Or CPC
@peterigrenyi9176
7 ай бұрын
Dont bother. Its crap. Sray away from TIS. U look at it wrong and reading jumps massively. Gentle breeze throws readings off. I took mine steaight back and paid tripple the £££ for Fluke.
Пікірлер: 27