Good working! next full video without cuts. thank you 😎🇧🇷
@BonMj
11 ай бұрын
Thanks
@bigg1599
3 ай бұрын
Does it matter the what head I put on it because I see that it’s originally-40 part number and I put on a -80 and it seems to work fine is there a difference?
@shaikhsayeed6456
11 ай бұрын
Thanks for sharing video
@BonMj
11 ай бұрын
Welcome
@alamroushan9351
6 ай бұрын
Hi sir I have a question please reply my sms regarding Mitsubishi VRF 1remote to contact 2 Hiwall unit error 6607 so we chake and units switch we off so other units is working 1unit no working and remote also working before remote just to second on after off so please explain this porblam
@peramaraj2763
9 ай бұрын
I have a doubt sir VRF city multi -03 nos of CUs have 1st is master ,second is slave and third is backup unit so master and slave one of the two break down or both can auto start (hik) backup unit or not please advice bro 0:20
@reshvinabdulezimov1184
11 ай бұрын
Hello, which computer program do you use to view the vrv outdoor unit? How is it accessed over the internet? Is the program you use different for each model? I would be grateful if you could tell me this. I have a Mitsubishi heat pump and a Toshiba heat pump.
@BERESHIDA2008
11 ай бұрын
He uses an interface to conect to the unit and the software in this case Mitsubishi. Most brands have diferent interfaces
@peramaraj2763
11 ай бұрын
I have a doubt sir daikin multi sys-3 Using checking D-checker 03 nos of units eev opened but indoor side 01 nos of totally no have cooling running time after turn off faster coming cooling on offcoil
@BonMj
11 ай бұрын
Check thermistor
@peramaraj2763
11 ай бұрын
Thanks for your update video sir
@BonMj
11 ай бұрын
Always welcome
@naylinoo8501
8 ай бұрын
👍
@BonMj
7 ай бұрын
Thanks
@bluecollardownunder3616
4 ай бұрын
any suggest on where I can buy MITSUBISHI MAINTENANCE TOOL?
@BonMj
4 ай бұрын
Mitsubishi Electric
@bluecollardownunder3616
4 ай бұрын
@@BonMj obviously it’s not from DAIKIN
@chrismorton5460
Ай бұрын
He gave you a direct answer as to where to buy the tool required..@@bluecollardownunder3616
@user-hh8xv8fl9g
2 ай бұрын
6600 error code what is the problem
@tharthaw9693
11 ай бұрын
Which unit did you replace the Lev for FCU 1or both?
@BonMj
11 ай бұрын
FCU 1 replace LEV FCU 2 replace thermistor
@tharthaw9693
11 ай бұрын
@@BonMj Thanks Uncle ❤️
@servicio2009
10 ай бұрын
FCU 2 TH2 Failure@@BonMj
@bloopblop-ox3dd
11 ай бұрын
where do you get your heatblocking putty?
@BonMj
11 ай бұрын
Online
@peramaraj2763
11 ай бұрын
Daikin system -4 any one unit we can bypass ?
@BonMj
11 ай бұрын
What you mean system 4, multi split?
@peramaraj2763
11 ай бұрын
@@BonMjtemporary can you bypass any one unit's expansion coil because EEC faulty
@IvanHernandez-sm9qr
9 ай бұрын
Hello, what's the name of the software?!! And where can I download it?
@IvanHernandez-sm9qr
9 ай бұрын
Hello, what's the name of the software?!! And where can I download it?
@BonMj
9 ай бұрын
Only Mitsubishi can do for you
@user-mj5fv7li7k
11 ай бұрын
Hi are you from Singapore? Do u do aircon service? How do I contact you?