*** Rotating Drive
How To repair a working RAID 1 array on Dell T610 PERC6i when one drive
is missing.
This procedure shows how to reintroduce a drive to repair the array.
This sequence used a previously used drive, into a system with PERC.
This is a reference video on a Dell T610 with PERC6i
It is useful after removing a drive for a backup [whilst shutdown].
Prior to power up one disk has been removed from the PC
*** Run Config Utility
Catch the boot sequence, and Run Configuration Utilty for PowerEdge Expandable RAID Controller
When rebooting PERC reported: 1 Drive Degraded, because the configuration used here was for two drives RAID1 and so far only one is installed.
But this can be ignored and the Server will try to boot on the installed disk.
*** PERC Inspect Status
PERC Introduction
*Use Ctrl-P and Ctrl-N to move across the tabs
*When selecting options, the active highlight is dark blue
*** PERC Virtual Disk Management
*Raid 1: One disk is removed and this is reported to be Degraded
*Open up the Physical Disks
*Counts, only 1 Physical Disks
*Can see one online and one missing
Now you can insert the disk to be rotated in, it is vital to use good labelling and logging of drives in use.
*** Insert Replacement Disk
PERC Physical Disk Management
*A Foreign View should now appear
*Use LED Blinking to verify that the listed disk is the one just inserted.
*** Clear Foreign View
PERC Foreign Config View
*Clear the foreign View
*Confirm
*** Rebuild Disk
PERC Virtual Disk Management
*Still shows degraded, but...
PERC Physical Disk Management
*Shows ready
*Highlight the disk's line *F2 operations *Global Hotswap
*Question: Give priority to enclosure?
No [highlight is dark blue]
*The disk state changes to Rebuild
PERC Virtual Disk Management
*Open up the Physical Disks
*Counts, now have 2 Physical Disks
*Can see one online and one Rebuild
*** Reboot
IMPORTANT do not power off
during the rebuild
However you can exit PERC, and bootup
the rebuild will continue
*Use 'Esc' to exit *OK to confirm exit *Followed by the usual process to reboot
*** Disk LED status
*Two LEDS each: status and activity,
the rebuilding status LED will be blinking.
Both activity LEDS will be flashing rapidly
*** Summary
The Server will try to boot, as in this linked video.
More technical videos on the doctorBob Applications channel