I’m 25 now, I started my plumbing career at 22 because of Roger. I always beat myself up for not starting earlier. But I’m in my own truck now (im a service plumber), I average 3-5 jobs a day, and I am always learning. I’m halfway through school to get my journeyman license (I should be a journeyman by 27-28?), and I am so grateful for the chance to get into this trade. Thank you Roger.
@porschepal7932
8 ай бұрын
I have a tremendous amount of respect for legitimate plumbers. There are far too many fakes out there trying to scam people. Thank you Roger for what you do.
@michaelandres1363
8 ай бұрын
Plumbing Journeyman from Hawaii here. Just speaking on what we'd be required to do and comparing it to what you guys need to do in Texas, we'd need to add in earthquake straps due to all of the seismic activity that we have. Also, since our water is fairly clean, we recommend changing anode rods every 5 years (3-4 in areas with harder water). My personal cut off for servicing is 8 years but that depends on the condition of the heater. Thanks again for the video. It's always fun to see what other pros pick up and point out. It's a great way for iron to sharpen iron.
@Bingus2000
8 ай бұрын
Keep it up Roger! I'm currently a third year apprentice and have been learning a ton from you for a while now. Cheers!
@THR33-LAWS-SAF3
6 ай бұрын
In my part of Arizona we recommend having a thermal expansion tank as well as an electrical quick disconnect for electric water heaters. My company hard pipes all copper and we don’t use flex lines for anything other than portions of the gas supply when not using black iron. I’m still learning though!
@leor2252
Ай бұрын
Yooo working with HomeRenovision? You both do a great job!
@ralphfryer7337
Ай бұрын
Gidday Roger, I hope when you install a new HWS you will also install a Carbon Monoxide detector/automatic gas shut off valve and also a Mildred valve? Why on earth was the drip tray outlet valve capped off. Hopefully you could install a tundish on the new install?
@MoisheFriedman-lj7ky
8 ай бұрын
Roger it was an honor to meet you today at the wett show
@boldbearings
8 ай бұрын
These are fantastic. 😂 Subbed ✅
@RogerWakefield
8 ай бұрын
Welcome aboard!
@raymondjacobs8429
8 ай бұрын
Roger up here were we have basements, NY, we set the tanks on some sort of concrete block to get it off the floor and get some room for the hose when draining, for the flush unless the flue is low. I had problems draining tanks, the service guy said for me to leave the water on till I got a flow going, then turn off the supply, it would drain after that.
@scottapt5291
8 ай бұрын
Roger, do you have any experience or opinions on the powered anode rod units?
@larrytheplumber9851
8 ай бұрын
Yzerman
@scottapt5291
8 ай бұрын
If there is nowhere to run a pan drain, I cap the outlet and place a water alarm unit in the pan to give an early warning of an issue.
@TheWeekendGamerz
8 ай бұрын
The thing with not manually operating the t&p valve is you have to assume it will function currently when the limits are exceeded in the water tank. You assume its "safe". I have ran into several boiler that were over pressurised and the relief didnt pop.
@tacklebox6239
8 ай бұрын
This guys a pencil pusher. He’s afraid to actually have to do some real work.
@loumitch1
8 ай бұрын
Problem is that the anode rods are installed to tightly at the factory, it can be extremely difficult or impossible to loosen and remover. Another thing I don't like is that on some water heater brands, the anode rod is combined with the hot water outlet. Sucks
@juanvaldo666
5 ай бұрын
Thnx
@christopherprivette7383
8 ай бұрын
Badger water meter 5/8 3/4 inlet body had a register that match but the register was changed to a 2 in will that cause a problem
@williamnunez9609
8 ай бұрын
Have you heard of Corro-Protec anode, is this a game changer or a waste of time.
@semo6229
8 ай бұрын
Did I just saw Jeff from home renovation 3:29
@jacobboss6311
6 ай бұрын
It's a TPR Valve and it should drain into an indirect waste disposal container in the same room as the water heater
@DrainMedic
8 ай бұрын
Im always surprized most of the country doesnt use vacuum breakers.
@User-y9t7u
8 ай бұрын
Be cool if you showed the stuff you were talking about at the end. Especially the draining of the pressure
@sleektoneofficial
8 ай бұрын
I dont like that the tnp is going into the wall. In my state they need to terminate at least 2” from the saftey pan
@swackhammer2139
8 ай бұрын
Similar here. Needs to terminate between 2-6" above flood rim of the pan
@TheWeekendGamerz
8 ай бұрын
In Mass its max 6in off the floor. I dont think they would pass the t&p cause its passing through the wall
@solidsnake2085
8 ай бұрын
Running it into a wall is a bad idea IMO. At least in the IPC it says that they need to terminate 2 to 6 in from the pan or in a conspicuous location. If it is going into a wall you'll almost have no idea it's ever leaking.
@kirkdarling4120
8 ай бұрын
In my jurisdiction, if the water heater is inside the house (not in the garage), the TnP must terminate _outside_ the house between 4 and 24 inches from the ground. So, an inspection would require checking that out.
@sleektoneofficial
8 ай бұрын
@@kirkdarling4120 oh ok around here ive been told they want people to be able to see its leaking only water heaters i see where they run elsewhere are old.
@pedrosmits
8 ай бұрын
We remove them every week, and replace them with indirect heated boilers. A lot of heat is lost because of the exhaust running in the middle of the water. The air inside the exhaust is heated by the surrounding water, and will exit naturally. New air gets sucked in, and you’ll lose a lot of heat during the day. Also scale will build up surrounding the exhaust, and it will limit the heating exchange capabilities. Calcium is an excellent isolation product.
@fitter1972
8 ай бұрын
Shouldn't you advise them to get that water heater off the floor?
@RogerWakefield
8 ай бұрын
Yeah I plan to do a lot with that back part of the house, so eventually it’ll get fixed
@sleektoneofficial
8 ай бұрын
First thing wrong with that heater is its an ao smith and theyre shit
@matttremblay8225
8 ай бұрын
Leaking carbon monoxide into the house fur sure
@larrytheplumber9851
8 ай бұрын
I was thinking tht to
@zoubeirfaouzi149
8 ай бұрын
This man deserves more likes. Sharing is caring 🤎🪠
@mattmcdonough6831
8 ай бұрын
Hey Roger how can I send you my phone number? LinkedIn isn't working for me.
@ambermendoza11
8 ай бұрын
Hey Matthew! you can send it to me. If you send it to the website Rogerwakefield.com I'll get it. Or you can use my linked in.