Dear,Our Engineer Think The Problem Should Be On The Gap Between Cams With Dial Or Cylinder. Therefore, Please Follow Below Steps To Solve Problem. Point Is The Right Gap Should Be 0.15MM---0.25MM.
Step 1, Use 0.1MM And 0.25MM Iron Stick Seperately To Cross Gap.
Step 2, If Wasn't In Right Gap,Lossen The Screw Of Wrong Part First,Then adjust By Loosen(Gap UP)Or Tighten(Gap Down)
All This Screw should Lossen Firstly.
Then Adjusting By Those Screw.