Mr harpreet singh This is piyush from Gujarat I would like to talk to you on this freshwater generator, Can you please right you email id on this
@marineengineerbudiriyanto.1969
4 жыл бұрын
Thank you
@Adventure-Story
4 жыл бұрын
Welcome!
@nguyenconghung761211
7 жыл бұрын
thank you so much .
@marckninoabecoronel5748
4 жыл бұрын
Hello! Why is it essential to close the air vent valve ? thank you!
@Adventure-Story
4 жыл бұрын
Marck Hello air vent valve must be closed because if we leave it open vaccum will not go down.
@marckninoabecoronel5748
4 жыл бұрын
Thank you good sire! I have been searching for a lot of references and I have came with that conclusion. Since my conclusion have been validated I feel a lot more relieved. Good fortune Sir! Stay safe!
@Adventure-Story
4 жыл бұрын
@@marckninoabecoronel5748 Thanks for watching!
@dungnguyenduc645
7 жыл бұрын
thank y so much!can you show me how to start OWS systerm!
@Adventure-Story
7 жыл бұрын
+Dung NguyenDuc sure i will show .
@bestgamezone9311
2 жыл бұрын
Sir when we open the sea water FW inlet v/v, how much time taken to fill the fresh water generator, how we came to know.
@Adventure-Story
2 жыл бұрын
Freshwater generators have always a site glass from where you can see all necessary water levels and vacuum is also very important to be established before run the evaporator about the time if everything is proper adjusted 5 to 10 minutes is ok.
@ramanmarara5154
2 жыл бұрын
Sir why is pr gauge provided before the overboard vv??
@Adventure-Story
2 жыл бұрын
Because it is necessary to monitoring the pressure for finding any problem in the system.
@caretobare7531
7 жыл бұрын
good day how can i download this simulator? pls response coz i need this
@user-gf6gi6bq6g
4 жыл бұрын
WHERE I CAN TAKE IS YOUR PROGRAMM. YOU MAY ME GIVE HER
Пікірлер: 24