Can we use this for 3 phase motor in the continuity mode?
@The.Innovative.Indian
7 ай бұрын
No, its current tolerating capacity is not to handle three phase motor. You have to look for other options. Or one thing you can do, you can use a relay. You will drive the relay with the help of this float sensor, and then relay will drive the three phase motor.
@marwanayache
Жыл бұрын
Hi. It is good to measure the well depth and water level, the question is how depth can this still give signal? up to 100 meter depth do you think it will work?
@The.Innovative.Indian
Жыл бұрын
Yes you can use this for 100 meter depth.... Just use 7805 based signal booster using resistors to get signals for long distances....
@clamman7505
10 ай бұрын
did you work for oceangate by any chance sir?
@sudhakarsaravanan8762
3 жыл бұрын
Thank you Sir.
@The.Innovative.Indian
3 жыл бұрын
welcome
@ramakrishnanswaminathan3654
5 ай бұрын
Are u having finished product.
@The.Innovative.Indian
5 ай бұрын
We have used in various products because It can be used in various products .... In which product do you need it...
@nihalj3645
3 жыл бұрын
Can we remove and change the position of the float to make normaly open or normaly closed?
@The.Innovative.Indian
3 жыл бұрын
Yes both types of float sensors available in the market
@clamman7505
10 ай бұрын
there is a video where it is shown that the ring is taken off, reversed and then put back on in the other direction and then it should make normally closed into normally open and normally open into normally closed but it is not clear how that works. can you please look into this sir?@@The.Innovative.Indian
@jamesarulrayan1955
9 ай бұрын
Sir, shall we connect magnetic float switch directly with 24 volt RO pump?
@The.Innovative.Indian
9 ай бұрын
No, directly connecting a magnetic float switch to a 24V RO pump is not safe due to potential overload, inrush current issues, and lack of protection. Use a relay or contactor for safe and efficient control.
@abhishek.m05
3 жыл бұрын
Please provide link to buy this good quality product
@The.Innovative.Indian
Жыл бұрын
It's given in the description... plz go through that....
@jamesarulrayan1955
9 ай бұрын
What is the current capacity of this reed switch?
@The.Innovative.Indian
9 ай бұрын
The current capacity of a magnetic reed switch can vary depending on its specific design, size, and intended application. Reed switches are often rated for a certain maximum current and voltage. Miniature reed switches: 100mA to 250mA Subminiature reed switches: 50mA to 100mA Standard reed switches: 0.5A to 3A High-power reed switches: 5A to 10A
@jamesarulrayan1955
9 ай бұрын
@@The.Innovative.Indian Thank you sir
@nitinbokade214
4 жыл бұрын
Hi, pls advise the cost of such float sensors generally used in Kent Maxx or any other storage water filter.
@The.Innovative.Indian
Жыл бұрын
150 rupees indian rupees
@abhishek.m05
4 жыл бұрын
Can magnetic sensor be immersed under water? Is senor water resistant? Can I use this at mid of water tank? Is there any chemical side effect of damaged sensor?
@The.Innovative.Indian
Жыл бұрын
yes, you can immerse this in water .. it's water-resistant ...... yes you can use it in the mid of water ....... because its made of plastic , so you can use it in mild chemicals
@actechbd3726
3 жыл бұрын
Thanks bro
@The.Innovative.Indian
2 жыл бұрын
Thanks❤
@Tearflavoredcereal
3 жыл бұрын
Why do you use the resistor with the led? Do I have to have a resistor ?
@The.Innovative.Indian
3 жыл бұрын
To Drop the voltage
@talashganvir4144
3 жыл бұрын
which material is used for that floating tube and can I used for battery
@The.Innovative.Indian
Жыл бұрын
Actually, we use three things 1. Reed Switch 2. A Magnet 3. Plastic Casing
@luisirizarry2767
2 жыл бұрын
Need help with my float. Apparently got stuck under continuity causing a motor controller to think the tank is full and not turning the water pump when needed. Replaced with new and still causing issues. How can I make it reset the system?
@The.Innovative.Indian
2 жыл бұрын
Your questions is not clear. As far as I can understand you are asking the continuity problem actually in these sensors you will get normally open and normally closed sensor. You can use according to your requirements
@actechbd3726
3 жыл бұрын
Nice bro
@The.Innovative.Indian
2 жыл бұрын
Thanks❤
@mhomam3297
2 жыл бұрын
Hi In the event that I want to work in reverse when the moving piece goes down, how do I benefit from it, and how can I get it in terms of pricing and shipping to Saudi Arabia for 5 pills as a sample? Thanks
@The.Innovative.Indian
2 жыл бұрын
Just used some a darlington pairs of transistors, if you want to reverse the operation
@keeplearning3937
4 жыл бұрын
How to stop buzzer sound when water level is full? I don't want buzzer to buzz continually until water level drops.
@The.Innovative.Indian
Жыл бұрын
So, in that case plz use microcontroller ...
@muralisaravakota3082
4 жыл бұрын
Thank you
@The.Innovative.Indian
4 жыл бұрын
You're welcome
@shabirbhat3841
2 жыл бұрын
How much load i can pass through reed switch i need to pass 50 watt . Water moter i want to use this reed switch for on /of for my moter can i?
@The.Innovative.Indian
2 жыл бұрын
I have used small capacity reed switch..... They can't run motor directly..... You can buy high capacity read switch😊👍
@michaels8297
4 жыл бұрын
can i use this to measure water level?
@The.Innovative.Indian
Жыл бұрын
Absolutely its made for that ....
@manpreetsandhu3885
2 жыл бұрын
Brother can you use liquid level sensor..
@The.Innovative.Indian
2 жыл бұрын
You can use these Magnetic Sensor as a liquid level sensor
@magedibrahim8353
4 жыл бұрын
If I want this sensor to do the opposite, when out of water it is continue ( light on) and when in the water ( I mean water level increase) it no continue ( light off) ?
@NebbieLoon
3 жыл бұрын
kzitem.info/news/bejne/wIOM0WyjiJSKlXo
@lynilthomas8926
2 жыл бұрын
Use a relay and connect use normally open terminal of the relay.
@The.Innovative.Indian
Жыл бұрын
Normally closed Float sensor available in the market...... or you can use them in upside down direction if you want to use the same sensor..... i have used this way .....
@clamman7505
10 ай бұрын
sir could you please explain further the relay is used how? what relay should be used and how to connect this float when used with a car battery or 9v battery and a small motor to open or close a water inlet valve? I am thinking of building a cascading water feature. can you please explain how and what is needed. thank you.
@The.Innovative.Indian
10 ай бұрын
@@clamman7505 The Relay you can will use is 12V or 5V Electromechanical Relay. But you have to use driver in between the relay and the sensor because sensor current is too low. you can use bc547 transistor as a amplifier to amplify the signal from sensor to the relay. further in the relay there is three important pin common, normally open, normally close. learn how to use them by watching tutorials then you will be able to connect anything to this arrangement. 😇
@kartiksharma2196
4 жыл бұрын
इसका प्राइज क्या है और ये कौन कोनसी शॉप पर मिल सकता है।
@The.Innovative.Indian
Жыл бұрын
Brother link is given in the description....
@healerkumarasamy1115
4 жыл бұрын
information is very useful .I looked for my tank water level controller. i need floting sesor any contact no please.
@The.Innovative.Indian
4 жыл бұрын
Check description
@MrIniadoc
3 жыл бұрын
As soon as the magnet comes in contact the motor switches on...water drops to few level, then the magnet looses contact..😂😂..motor stops there itself...we need something where when the tank is full, the motor starts then stops only when it has pumped out some considerable amount of water..like a float switch...why do you need a reed switch and a magnet to complete the circuit😀😀?! Just keep one end of a wire at top and attach other end to a simple floating material, so when the tank gets full both ends of the wire make a contact and the buzzer rings..😂😂
@lynilthomas8926
2 жыл бұрын
But enclosing such a swith with bare open wires is a hassle. This is inexpensive
@clamman7505
10 ай бұрын
fried fish anyone?
@rajanthakor9929
3 жыл бұрын
48v dc 5A warming
@The.Innovative.Indian
3 жыл бұрын
you can pass 5A current from these
@bittu1015
4 жыл бұрын
Oll are fine
@The.Innovative.Indian
4 жыл бұрын
Thanks
@rishabhjain2127
4 жыл бұрын
Bhai jab English bolne me problem hai hindi me video bna liya karo
Пікірлер: 66