Could spend the all day watching your tutorials... not an electrician and won’t venture there but it’s simply so interesting and at last I do understand something...
@ecologicaltime
2 жыл бұрын
thank you
@zzvannie
2 жыл бұрын
Wow I always thought the db boards were so complicated but your video makes everything so simple to understand. Thank you!!!
@jeremiegibangokantin1941
Жыл бұрын
so genius, born to teach …you have gained all my respect sir
@phalengholdings8239
3 жыл бұрын
This guy is very clever, I normally put earth leakage just after double pole circuit breaker then put my bridges the other way round but I make sure that my lights are not under earth leakage,,,,,,, ur explanations are so useful bro
@glendagorogokunia9442
Жыл бұрын
Best explanation and tutorial.. Straight Outer from Papua New Guinea 🙏💥
@eastomega
Жыл бұрын
this channel has helped me a lot , I wish I had enough to buy you a drink every time you teach😊
@danielfadd
2 жыл бұрын
You do realize that you were born to teach other's -dont you? Top class tutoring,straight to the point with no confusing bs and just very easy to follow while being very informative and interesting .Nothing but respect and gratitude my fellow South African..Kwaai lappies my Broer .☺
@ecologicaltime
2 жыл бұрын
Thank you, much appreciated
@dmr9042
3 жыл бұрын
if you are a teacher, I will not hesitate to go to school. you explain so well. Thanks fr sharing the skill. highly appreciated.
@ecologicaltime
3 жыл бұрын
thank you.
@paddajunior744
3 жыл бұрын
This gent really explains things so nicely, for anyone to understand. Thank you for such informative topics.
@ecologicaltime
3 жыл бұрын
thank you
@PanjiThame
Жыл бұрын
Excellent video. I learn from your technique and i will apply it. Keep up your good job sir. Thanks.
@ThembaVundla-iu3ug
Жыл бұрын
Oh how I love these tutorials❤️❤️ please loop a 3 phase db board, very much informative sir.
@stevensseagull
3 жыл бұрын
Thank you for the quality of your content, truly amazing. Best South African DIY channel I've ever seen, didn't know we got such here!
@ecologicaltime
3 жыл бұрын
Thanks! 👍
@maximumrespect1997
2 жыл бұрын
Excellent..... thank you sir.....very informative and deadly accuracy.
@SnowyPe
3 жыл бұрын
Great explanation..100% understand what to do now wiring a db board to an inverter supply
@entlungwini2570
2 жыл бұрын
Teach me teacher!!!, great lecture thank you sir 🙌👌👍
@roderickjohnson1677
Жыл бұрын
This is how I was been trained on distribution boards 9 out of 10 score for you Mr electrician
@wilsonokibe8431
2 жыл бұрын
I just learned what seems so difficult like an easy task. God bless you real good. This task is amazing. I trust that God will continue to use you to educate minds and prevent hazards. From this lesson, I can carefully examine a DB and wire a building. I believe so. But the issue now is how to handle multiple plugs or lights. Hope to find another link.
@thee_crocodile3270
Жыл бұрын
You need to bond you need a fish line you need a multimeter yes
@mapoletswele8174
2 жыл бұрын
Great demonstration, thank you 🙏🏿🙏🏿🙏🏿.
@roryfreeman9433
3 жыл бұрын
That double green lever switch is an isolator and can not trip on short circuit or over load. The white and green of the earth leakage switch on the other hand is an isolator, short circuit and overload protection as well as earth leakage protection.
@ndlovubhekimpilo7619
3 жыл бұрын
All answered wonderful explanations
@jmunshi
2 жыл бұрын
Great video, very well explained. How does one identify the neutral wire for a circuit once the db board is complete should there be a need to move circuits to EL or direct supply?
@thulanijohn620
3 жыл бұрын
Thank you so much Sir. Please assist me also on 3phase New DB Thanks you are a life saver
@user-cz2fp7pt7q
3 ай бұрын
Thank you sir. I appreciate
@FynbosGarden
3 жыл бұрын
crystal clear. man is a credit to KZitem
@QuestionHartmann
2 жыл бұрын
Nice demonstration!
@nathimngadi764
3 жыл бұрын
One of the best videos in south africa thank you very much 💙💚💜💜🧡 🤍🖤 l wish one day you can teach us about lights using contactors single phase
@ecologicaltime
3 жыл бұрын
thanks
@tshepomashabelangatane7960
3 жыл бұрын
im perfect now. thanks for detailed info
@BERichProjects
3 жыл бұрын
Thanx for the info. It helps alot. Can u tell me what size breaker I shoud install for a borehole pump and if it should be wired to an earth leakage breaker. Thanx
@sivapillay8206
3 жыл бұрын
In detail and understanding.
@denzelm1000
3 жыл бұрын
Great explanation
@mysteriousgamer4463
3 жыл бұрын
Thanks for the info.
@littlepeoplesmontessoripre5564
3 жыл бұрын
very informative
@martinkotze7258
Жыл бұрын
Thanks very much, your video's have helped me a lot so far. What will happen if I put everything on earth leakage? Putting some stuff not on it will complicate things too much because I'm planning 2 rows of modules: top row for ONLY Escom, and bottom row for EITHER Escom OR Inverter via change over switch. (The bottom row will have its own neutral bar.) Furthermore, do I have to have 2-pole breakers (L+N) that lead to subpanels in my lapa and garage? The subpanels have their own L+N main switches.
@musasamatheus1726
3 жыл бұрын
It help alot... thanks
@Collinnaidoo5276
6 ай бұрын
Hi thank you for the video its very informative. I have a question can i use a 4mm wire for a 20 amp breaker for my gyser. My gyser has a 30amp breaker now it has to be replaced. Thanks
@isaacngigi4946
2 жыл бұрын
informative.. educative i like it
@clementbanda9775
Жыл бұрын
Thanks for your help me
@Admimistrator
3 жыл бұрын
Great explanation on how this works.
@maxhofmann6993
5 ай бұрын
I just recently upgraded my geyser element to 4000W and had to upgrade the breaker as well. My db still uses the old breakers and I discovered my geysers breaker had an in built isolater switch. However my geyser has an isolater in the roof about a meter away from it. Was it illegal for me to change the setup?
@TrevorKhathi-gu1tu
Ай бұрын
Thank u sir🙏
@skunkle100
4 жыл бұрын
good, thanks
@ASHRAFALI-br7iq
3 жыл бұрын
Thank you
@trentjoel7901
9 ай бұрын
Good
@BartholomewOpara
2 ай бұрын
Yes Thank you 😊
@joziboy8673
Жыл бұрын
Can one use 2 single pole MCBs instead of a double pole main circuit breaker? I have a old jhb house with a faulty 80amp main supply cb and cannot get a 2p 80amp mains breaker, i can only find 2 80amp single pole breakers. Most houses are 63 amps can one step down to a 63amp supply from the original 80amps or does one need to keep the 80 amp breaker in place?
@mooningrelaxation5480
3 жыл бұрын
very nice
@michaelcostello6991
3 жыл бұрын
This was really helpfull. Thank you
@ecologicaltime
3 жыл бұрын
You're welcome!
@lechzekjacobs2752
3 жыл бұрын
Great video, very well explained. I had no idea that added neutral bar fits perfectly into a samite rail. I've always just screwed them to the board. A quick glance at your main switch seems to indicate that it's an isolator (2 green toggles = no overload protection) instead of a circuit breaker (white + green = overload protection) in which case, your main switch won't trip on a fault. I suppose you were just using it for illustrative purposes?
@ecologicaltime
3 жыл бұрын
I have contacted CBI and they confirmed the details on their website was wrong. Many merchants have wrong details: 1drv.ms/b/s!AnwSVs2Nl8dGltpb9pAEsawaRr5ekg?e=BFxVk8 Will have to fix this video
@ecologicaltime
3 жыл бұрын
The lab had the wrong stock, will redo this video. thanks for your comment.
@lechzekjacobs2752
3 жыл бұрын
Happy to help
@thabisomodisane1435
Жыл бұрын
Is it wrong if i install everything in sequence double pole breaker next to it earth leakeage breaker then stove geyser and other loads?
@Choosen87
3 жыл бұрын
Nice stuff bro ! Please explain how when any switch is down you say it's open? Is because it's not connected to make it a full circuit?
@ecologicaltime
3 жыл бұрын
yes down means it opens the contacts
@lesibanahopekolobe2292
3 жыл бұрын
Nice Content 🚀👍 Quick question, where can I get the specifications of cable sizes and current carrying capacity? 🇿🇦
@ecologicaltime
3 жыл бұрын
Thank you. Cable manufacturers specify these things. The only issue is current spec changes depending on how the cable is run. www.cse-distributors.co.uk/cable/technical-tables-useful-info/table-4e1a/ Generally its: 1mm=14A; 1.5mm=19A; 2.5mm=26A; 4mm=35A
@lesibanahopekolobe2292
3 жыл бұрын
@@ecologicaltime Thank you for the update 🙂 keep going strong 🇿🇦🚀
@mirriamsinkala2644
10 ай бұрын
In place of a earth leakage , can we use a lightening arrester
@isaacbusinge7509
Жыл бұрын
Sincerely there are mistakes I have been making but am gonna correct them now🤝👏
@ecologicaltime
Жыл бұрын
thank you. Please just note that the main breaker must have over current protection. See example here: kzitem.info/news/bejne/t36vrKBjsmmJdnY
@luckyboysen5169
2 жыл бұрын
Super
@thandekamalaba2301
Жыл бұрын
Great
@bonganimokoena8328
Жыл бұрын
What's the again of not protecting the lights?
@zubairally7625
3 жыл бұрын
Could you do a 3 lever switch to 3 lights...please
@gaminggaminglast2723
3 жыл бұрын
What is better Earth leakage protection breaker Or Rccb
@mkululigqamane4252
3 жыл бұрын
👏👏👏
@ashwinshadygold6277
2 жыл бұрын
I'm using new brain cells thanks man ....can you wire a Sam surge protector please
@elishatech4600
3 жыл бұрын
Here in Zambia the Neutral Wire and Earth Wire are Connected together for bonding purpose. Is that correct Or a mistake?
@ecologicaltime
3 жыл бұрын
the Neutral is also there to assist with protection. It depends where in the system they are bonded.
@elishatech4600
3 жыл бұрын
Thanks.
@ridoois6698
2 жыл бұрын
When do we have to bond neutral and earth?
@langarock5883
2 жыл бұрын
Please sir tell me why did you put earth leakage among breakers
@johanvandemeeberg9995
2 жыл бұрын
To protect you at the plugs,electrucation etc.
@brightsideofsaturn
4 жыл бұрын
What is this db board used for
@ecologicaltime
3 жыл бұрын
teaching students. You can use this for outbuildings and small homes
@leonfroos
3 жыл бұрын
Wrong main switch. It doesn’t have overload protection . 5.3.5
@ecologicaltime
3 жыл бұрын
Thanks. But this one is listed as having overload and short circuit protection: www.voltex.co.za/product/cbi-isolator-63a-2pole-3ka-qal20063/ I think they have the wrong details for this isolator. Will have to change the video.
@ecologicaltime
3 жыл бұрын
the video is being filmed again. New one to be uploaded. thank you
@leonfroos
3 жыл бұрын
Yes must be a mistake. I work for the electrical inspection body. Here to help