Thank you sir . Now i got some informations in this videos
@user-eh1gh7vv1l
Жыл бұрын
Super bro...💥
@saikrishna3977
2 жыл бұрын
Thanks so much sir
@ankurkashyap5941
2 жыл бұрын
Very nice 👌👌👌👌
@premkumarovr6388
Жыл бұрын
Thanks sir
@PAss-jt2jw
3 ай бұрын
If there is a chance to isolate we will isolate the block valves degassing the gas to scrubbing system.
@garysmith859
Жыл бұрын
Awesome video man. I’m an SRU Operator, Amine, TGU Amine based sulfur recovery unit, SWS as well.
@bharathkumarjarajapu2854
3 ай бұрын
Sir Can you explain me
@zagade111
Жыл бұрын
Very nice information 🙏🙏 Just one humble request to make a mechanical supervisor or engineer interview questions for the SRU
@zahirmaruf1621
5 ай бұрын
5:40
@navaskhalid3134
Жыл бұрын
Very informative thank you.please upload next part.please do panel Operator interview questions.thanks in advance
@chemicaldiary8412
Жыл бұрын
Sure I will do that
@PAss-jt2jw
3 ай бұрын
If find the leakage of H2s,wear required PpE and check the wind direction,give information regarding leakage wind direction and spot to the Shift engineer and DCS operator
@gokulradhakrishnan14
2 жыл бұрын
Upload startup,trouble shooting,problem facing in SRU
@lavenisjc982
Жыл бұрын
Please mention where are we take sample in SRU and mention about sample description.
@babudeep835
Жыл бұрын
A fire in the sulfur pit will be detected by a sharp rise in the pit vent temperature. SO2 concentration in the sulfur pit will increase. Once high high (HH) temperature or HH SO2 activate, pit will be isolated by stopping the educators and by closing the educator vents to atmosphere and the incinerator sweep gas flow. Immediately open manual snuffing steam valve to the pit to extinguish the fire. A brown plume venting from the stack indicates a continuing fire. Maintain sulfur sump temperature below 160 0C. Above this temperature sulfur is highly viscous and pump cannot able to develop pressure
@chemicaldiary8412
Жыл бұрын
Hi Deep Its really good informative explanation about pit temperature. If you are selling liquid sulfur to other company and no intention to use inside the plant u can maintain the temperature such that it doesn't solidify. If your company utilizes the liquid sulfur in internal plant consumption then u need to maintain such temperature to have good combustion in making sulfuric acid
@iffazzy5988
Жыл бұрын
Uh Explained Very Well bro , Its very Under-stable in a easy way! Bro Can you Please share the PDF Format in Email ?
@chemicaldiary8412
Жыл бұрын
Email me I can share
@vimalsarvaiya7471
9 ай бұрын
Cold startup please
@saikrishna3977
2 жыл бұрын
Very helpful 👍👍
@chemicaldiary8412
2 жыл бұрын
Thanks dear Subscribe to my channel
@karthicklingadurai5021
Жыл бұрын
@@chemicaldiary8412how many areas in sru ? For one field Operator's responsibility
@chemicaldiary8412
Жыл бұрын
@@karthicklingadurai5021 It depends on the capacity of the plant Smaller plant One plant can be taken care by one operator If bigger plant means bigger man power requirements And also it depends on what your company work they are making granulation or selling liquid sulfur or consuming for associated plant
@karthicklingadurai5021
Жыл бұрын
@@chemicaldiary8412 i attended an interview for a field Operator.. nearly answered all the questions.. but he asks a question line ( SRU has 4 areas .. in which area u responsible for?? ) . That I can't answered it . Did you know what those areas may be ..
@karthicklingadurai5021
Жыл бұрын
@@chemicaldiary8412 and they are granulating Sulphur
@sangeethasurya8032
2 жыл бұрын
Pl upload problems & troubleshooting of SRU PLANT
@chemicaldiary8412
2 жыл бұрын
I will upload soon
@murugesha3307
Жыл бұрын
If I get this of pdf format
@ziurrahman2431
Жыл бұрын
SIR lease reply if h2s gas release what action will be taken
@chemicaldiary8412
Жыл бұрын
If h2s realized your h2s gas detector beeps just move away from place seeing the wind direction Once your h2s detector is beeping means u r away from h2s hazards Then inform control room about leak to stop the process then gas neutralize has to be taken place and decontamination to be done hazamat team H2s is denser so mostly it remains at ground level.
@gaddamvenkatesh9715
Жыл бұрын
@@chemicaldiary8412 should carry the h2s gas or multigas detector before going field rounds. Should be check calibration also. Observe windsock direction
@saleemkhan-ki6ii
Жыл бұрын
What field operators checks in field round
@chemicaldiary8412
Жыл бұрын
Pump and machinery healthy ness Machinery sound vibrations Temperature and pressure all manually And by verifying with DCs reading Gas leak fire hazard Housekeeping Leaks And chitchatting with colleagues.
@yudhaprawira2947
Жыл бұрын
@@chemicaldiary8412The last point is so accurate haha
Пікірлер: 41