An EO2 error notification can pop up on the display panel if there is a water flow issue.
This can happen on any AirJet™ or HydroJet™ Lay-Z-Spa hot tub and there are a number of causes that can be fixed quickly and easily.
Quick EO2 error troubleshooting guie:
Cause 1: Freeze Shield™ has activated when setting up in the cold
- Instead, inflate the hot tub inside in the warm
Cause 2: Incorrect water level
- Check that there is sufficient water in the Lay-Z-Spa and that stopper caps are removed
Cause 3: Dirty or worn out filter
- Check filter. If necessary give it a clean or replace it with a new one
Cause 4: Worn out washers
- Follow steps to detach the pump and check the washers
Cause 5: Blocked debris screens
- Remove Chemconnect and filter housing. Clean the debris screens and dislodge any build-up
Cause 6: Filter housing
- Check the filter housing for damage or build up of dirt or debris
Cause 7 & 8: Blocked, kinked or bent pipes
- Disconnect the pump and inspect the pipes on the inflatable liner
If you need more help, please visit: www.lay-z-spa.co.uk/support/i...