Originally the MPC is equiped with BR-2032, is more expensive, but more last longingly then CR type
@my_ships_vlog3601
Жыл бұрын
Nice video
@AntonMoskvichev-ov7bx
3 ай бұрын
Read the manual it's enough
@ASHOKKUMAR-ti2yw
11 ай бұрын
Nice
@alexboiko2122
11 ай бұрын
Before to change backup battery is need to turnoff power on MPC 24V?
@gamelover2594
Жыл бұрын
need to be powered, after that you can replace battery, is that corect?
@marineinfotech2259
Жыл бұрын
MPC is powered by 24V DC supply and the backup battery provides back up power for clock frequency when 24v DC off due to any circumstances
@marineinfotech2259
Жыл бұрын
MPC should powered all the time and there are two ways to renew/change the battery 1-Turn multicolor RED dip switch from ON side to OFF side ,remove old battery and insert new battery after that put RED dip switch to ON. 2-Second way directly you can remove the old battery and LED indication on MPC will lit up red and you will get alarm on MOP monitor after inserting new battery the LED will blink orange continuously later few second it will turn to green LED after that you can reset the alarm from MOP. But it would suggest to follow you first way for battery renewal/change. Thank you
@alexboiko2122
11 ай бұрын
Before to change backup battery is need to turnoff power on MPC 24V?
@marineinfotech2259
11 ай бұрын
@@alexboiko2122 Nope
@24GAGAGA24
5 ай бұрын
Hello friend, can you tell me how to view the settings of the servise parameter/ update tool (arcEdit)? how to enter there
@marineinfotech2259
5 ай бұрын
Yes sure please send me mail on marineinfotech21@gmail.com
Пікірлер: 13