Please update more videos on ME Engine...across all the resources about ME engine on KZitem i have found yours to be more informative & precise. Thank you Sir ❤️
@abdullahalmasud7075
2 ай бұрын
Excellent ❤❤❤
@zubinbhatt299
8 ай бұрын
Exceptional knowledge bada Saab .and what a extraordinary way to make things simple.luck Are people who are sailing with you.😊🙏
@sealegend1627
8 ай бұрын
Hey man...thks for ur words...it's a precious comment have received... Appreciate it 👍👍👍
@manosskar2310
6 ай бұрын
Very important information, thanks Chief!
@sealegend1627
5 ай бұрын
Any time!
@malakadananjaya2046
Жыл бұрын
What a infirmative video ❤️
@tapanmukherjee338
5 ай бұрын
Well explained
@suleileinaing7997
4 ай бұрын
Thanks
@NitinKumar-gj4tq
Жыл бұрын
Great video sir !!
@kunalsharma6976
Жыл бұрын
Excellent video Sir..
@alexflarance1996
Жыл бұрын
Great video sir.
@dinulmanjitha5854
Жыл бұрын
great videos sir !
@sukruselimbingol7753
9 ай бұрын
👍
@pawan_maske
Жыл бұрын
Thank you for this informative vdo sir.
@Swapnilsb91
Жыл бұрын
Very Informative video sir Please update another videos like this
@theindianmariner8415
9 ай бұрын
❤️❤️❤️
@sultanhussain6051
Жыл бұрын
Excellent video , kindly share more videos regarding ME engine wether its MEC or MEB ...love your content Sir.
@junzkiesarona3414
2 ай бұрын
Thank you sir
@ravichandrakulkarni1571
8 ай бұрын
Nice explanation
@truongsophie317
Жыл бұрын
Could you please do more videos about generator,?
@gowithahmedopu5540
Жыл бұрын
Very informative video sir. watching from Bangladesh 🇧🇩
@sealegend1627
7 ай бұрын
Thks for your comment...M glad the videos are being watched on your land too...🤟🤟🤟
@harsharandeol658
7 ай бұрын
In this case what about about FIVA valve operation. I mean what to for exhaust valve hydraulic oil actuation ?
@sealegend1627
7 ай бұрын
Hey hi.... appreciate your query... In case of failure of MPC on a CCU or failure of the HCU of any particular unit....in that case the HCU design ensures it can be disconnected by using valve 420 and 421 on HCU from the system and perform any repair work on defective HCU with engines running. There will be no oil supplied to exhaust vv actuator. Also as mentioned in video, the exhaust vv is locked in open position...
@JishnuSaji
Жыл бұрын
Very informative video
@omom8622
Жыл бұрын
What is the reason for the unit being cut out ? What is the requirement to keep the Exh valve to keep open ? We can cut out unit in Running condition , by reducing rpm and then gradual reduction of fuel index of the concerned unit from MOP. Here Exh valve seat or spindle is burnt .Keep the cylinder lubrication on and don't run in new critical rpm when one unit is cut out. Awaiting your response sir.
@sealegend1627
Жыл бұрын
Hey thks for watching the video and coming up with ur doubts... The reason for the unit being cut out can be many.....for example - the MPC for the said unit is down,or the piston rings are given up,cracked liner, the CCU MPC is down and so on... Exhaust v/v needs to b kept open in two critical situation.....one when the lubrication system of unit is malfunctioning and secondly the combustion pressure is unable to b transferred to the drive gear........ Yes u can gradually reduce the fuel index in proportion to RPM and cut out the unit .. All the trouble shooting depends on various engine scenarios ....so the action u take must b correlated to those .....it's a vast topic brother and difficult to cover in few words...