How about verifying that the other end of wire doesn't have conductors touching.
@jslygld0301
11 күн бұрын
OMG, i love her voice so much
@jasonaldrich326
Жыл бұрын
Would be nice if they showed the sign on the meter...
@IWasNoah
Жыл бұрын
pretty self explanatory
@IWasNoah
Жыл бұрын
if you don’t know according to the IEC / ASNZS3000 it must be tested at twice rated voltage
@davidrosas2277
Жыл бұрын
True… so far all the cables we’ve megg have tested at 660 M ohms in all our cables we have tested / installed here at my plant, which is what it shows on the megger she’s using in the demonstration, but like they said 20 M is a pass.
@JuanMartinez-mf5bm
Жыл бұрын
You missing make test between red circuits cables or don’t apply this tests?
@ryanrahmat5980
Жыл бұрын
where do I put the red and black wires for testing a cable that does not have a ground braid?
@BARTECglobal
Жыл бұрын
Hi @ryanrahmat5980! If the cable does not have a ground braid, then one of the cable conductors might be the grounding conductor. For example, a three-wire cords contain two current-carrying (Hot & Neutral) conductors and a grounding conductor. Check the cable type and please note, for single conductor non-shielded cables, insulation resistance testing cannot be performed because low voltage single conductors do not have a grounding conductor, shield or ground plane. Hope this helps and thank you for watching!
@impala1977
Жыл бұрын
This is very helpful, thanks!
@BARTECglobal
Жыл бұрын
Hi @impala1977. We are glad you found it useful. Thanks for watching!
@reymondrono982
Жыл бұрын
All Wires minimum passing 20 mega Om's ?
@markgil9249
Жыл бұрын
Doesn't mention what this test is for? We know but you have to mention this of you're explaining it.
@IAmThe_RA
Жыл бұрын
To find out whether wires have the expected resistance value. Insufficient resistance means the wire insulation is bad and needs to be ditched as there risk of a ground fault or short circuit which can start a fire.
@Aquariun9iteMMare
3 ай бұрын
Let me guess... you're asking for a friend?
@shamsadeenmohamed5074
Жыл бұрын
Thanks alot..would you mind attaching a drawing for testing wirring
@BARTECglobal
Жыл бұрын
Hi! Thank you for watching. Please use the following link to download our design guide: www.bartec.de/en/downloads/heating-technology/engineering-tools/design_guide_iecex_final.pdf In page 36 you will find the "Tests and Commissioning" section. We hope this helps!
@ducatininja3866
Жыл бұрын
Ive recently run 140mts of heat trace. I did a test and getting more than 20 megaohms. However when the heat trace is turned on its drawing 54amps. Any suggestions?
@Chevroletcelebrity
Жыл бұрын
no
@CaltaTomas
10 ай бұрын
no :(
@chchandrasekhar3912
11 ай бұрын
What is the test voltage
@___Q-bot
9 ай бұрын
does anyone know what is the kind of the reel of red cable? is it for electricity or signals?
@barrelsage3784
23 сағат бұрын
Heat trace I believe
@arisan4567
Жыл бұрын
It's better if you show the results of your testing in the video
@BARTECglobal
Жыл бұрын
Hi @arisan4567 You are right! We are taking notes for future videos. Thank you for watching and for sharing your feedback.
@shahbazsindhu6616
Жыл бұрын
No it's was wrong because you are missing something. After testing must discharge cable...
@moristaneo9447
Жыл бұрын
you need to inject test also line to line and line1 to ground and line2 to gound. not only direct line1,2 to ground. need to separate
@BARTECglobal
Жыл бұрын
Hi! Thank you for watching the video. Most Meg sheets list L1-G, L2-G, but if they pass together they’ll pass separately.
@IAmThe_RA
Жыл бұрын
@@BARTECglobalwhat is her IG?
@jasonparkinson7621
Жыл бұрын
👍👍
@BARTECglobal
Жыл бұрын
👍🏽
@bennyb6071
Жыл бұрын
interesting, didnt know you can megger semi conductors
@ibnuabassmohammed8474
6 ай бұрын
Please you are too fast We are learning from it Next video slowly and let's see the values recorded too
@tfun101
Жыл бұрын
I’m sorry I don’t agree…we had 2 raychem techs come out to our site and Megger all of our heat trace. I worked with them for 3 days megging countless heat trace. I was told the minimum is 1 Giga Ohm of resistance “phase” to ground. They said specifically anything below 60 Mohms requires a level 2 diagnostic which is going out into the field and opening boxes to look for the problem. 20 ohms to them is a huge problem. With all do respect..what the f*ck are you talking about.
@joshuaboehler
Жыл бұрын
She said 20mega Ohm's not 20 ohm's. 20 ohm's is basically a dead short.
@tfun101
11 ай бұрын
@@joshuaboehler20 mohms, 20 ohms it doesn’t matter my guy. Read what I said.
@champ8605
8 ай бұрын
Depends on the voltage used for testing. They most likely tested upwards of 5kv whilst this test was under 500v. You're clearly not an electrician and dont know what you're talking about.
@tfun101
8 ай бұрын
@@champ8605 Most likely tested upwards of 5kv? 🤣. You’re sooo clueless bro..
@garza1367
7 ай бұрын
You were also told, face mask and vaccines would help stop/spread covid from “qualified” people… moral of the story, not every “professional” gives the right info
@essabhuyian2296
Жыл бұрын
ও লেডি বিউটিফুল ই ন্স টাক টার
@acefuellas2137
10 ай бұрын
why 550 meg is always the reading of a good insulation