Very helpful! Thanks for including the specific number ranges for good/bad solenoids and transmitters, etc!
@Hunter_Industries
5 ай бұрын
Glad it was helpful!
@sebaxh22
7 ай бұрын
Great video!!! Thank you for posting!!
@Hunter_Industries
5 ай бұрын
Glad you enjoyed it!
@farzingharahgozloo
4 ай бұрын
Helps a lot 🙏🌹
@Hunter_Industries
4 ай бұрын
Glad to hear that
@wstt4
8 ай бұрын
If I want to test two extra loose irrigation wires for continuity so I can add new zones on them, and I connect these loose wires at a solenoid, and then with my multimeter I touch both same colored ends at the base control box, and I get a reading of 1.0 Ω, is that a good enough result?
@AlejandroAste-Nieto
6 ай бұрын
So you created a loop with those wires? You tied them together at one end and tested resistance at the other? Then 1 ohm is a good thing. Your wires have good continuity. Smaller wire gauges will have more resistance the further you go. 18 AWG: 6.5 Ohm / 1,000 ft (multiplied by 2 for the wire to and from the end). So if you have 1 ohm on 18 AWG, that suggests you were 35-40 feet from one end to the other (70-80 feet of wire in a loop).
@shoyrushoyru
3 ай бұрын
I have a zone that has recently been causing awful water hammer noises when the sprinkler runs. I tested the AC voltage on the zone while running and it starts 26.2V but then immediately drops to 0V and quickly goes back to 26.2V every couple seconds. Does that sound like a station module issue? The transformer is giving a solid 27 volts. Edit: I replaced the station module and I believe the problem is solved.
@Hunter_Industries
2 ай бұрын
Water hammer is a hydraulic or water issue and is independent of electrical issues. It may be time to contact a local irrigation professional for help with your problem.
@truongvo1978
Ай бұрын
I have a Hunter 8 zone. I have a P ERR error. Error comes on every station. Doesn’t mattter what station I turn on manually. The error comes up right away. I tested all 8 station for continuity. Station 1, reads 50 ohms and stations 2-8 reads about 26.5 ohms. Is station 1 solenoid bad?
@Hunter_Industries
Ай бұрын
Please contact our customer support department here: www.hunterindustries.com/hunter-technical-support-email-request
@Son_of_Aragorn
5 ай бұрын
Is 16 AWG "marine wire" good for sprinklers? Wasn't sure if all 16 AWG wire are created equal. Thank you!
@Hunter_Industries
4 ай бұрын
Wire can vary with region and wire length. A local contractor or irrigation distributor can clarify.