4 ай бұрын
Nick, you have single handedly hit upon nearly every solar question I have ever had, including all of these "what if" scenarios. I may never connect multiple charge controllers to one battery bank. I may never combine the A/C outputs of two or more inverters capable of doing so, but then again, I might. But what is just as important, is gaining the insight into the characteristics of these components. That comfortable feeling of being in the ballpark of knowing what to expect is priceless. These videos are pure gold. I snagged your book off of AMZ.
@cleversolarpower
4 ай бұрын
Thank you for your comment. I do appreciate it as it keeps me making more content like this. 🙏
@wasistgluckeineformelfurgl7327
2 ай бұрын
Ich habe insgesamt 6 Laderegler parallel geschaltet. Es funktioniert ohne Probleme.
@cleversolarpower
2 ай бұрын
Lucky you! (Just kidding) Of course it works 😉
@GlobalSolarEnergyPakistan
2 ай бұрын
Good demonstration with proof of calculations.❤
@808pathfinder
4 ай бұрын
This subject can be tricky but you dumb it down nicely so I can understand more about these systems, ty👍
@cleversolarpower
4 ай бұрын
Thanks!
@mapbike
2 ай бұрын
Just ordered your book so looking forward to the shared knowledge you give in this book, this will help me get my off grid cabin setup and maybe I can help some friends also.
@cleversolarpower
2 ай бұрын
Thanks for your support! Send me an email if you have questions.
@mapbike
2 ай бұрын
@@cleversolarpower Thank you very much.
@The_Resistance_1961
Жыл бұрын
An excellent video which answered pretty much all my questions, and gave me some info I didn't know. I'm subbed.
@eddiepires3998
7 ай бұрын
very helpful. Clearly explained
@Cliflyri
22 күн бұрын
Fantastic, thank you for sharing this information.
@timgiddens9799
Жыл бұрын
Thank you so much! This is such a helpful video!
@user-wm4xd6rb8v
6 ай бұрын
Thank you for your answers to my question my friend
@ihavehotmail2
7 ай бұрын
Great explanation and diagrams. Now I have to learn about c-rate of batteries, do you have a video ?
@cleversolarpower
7 ай бұрын
Yes, check it out on the channel page using the search function.
@stevewhite9813
Ай бұрын
Well there we go thank you very much 😊 ☺
@moto-rambler
Жыл бұрын
Thanks for the video. It would've been more helpful to see where circuit breakers or fuses would go in the wiring diagrams you provided.
@cleversolarpower
Жыл бұрын
Thanks, I have made a video especially about fusing a solar system. Checkout my channel for more information.
@ekeretteekpo3004
6 ай бұрын
Thank you for the video. I would like to remark on MPPT controllers, particularly that they come with preset configurations for different kinds of batteries. I would think that the default for different types of batteries should rightly have taken into consideration their C rates and therefore control the charging suitably. No?
@cleversolarpower
6 ай бұрын
The charge controllers are only regulated for their charging parameters, not the capacity (Ah) of the battery they are charging. The highest current charge/discharge is mostly from the inverters, not the solar panels.
@mskman83
15 күн бұрын
Can both charge controllers be landed on a bus bar? I have a victron 100/30 and want to add another perhaps bigger mppt. Can both controllers be connected to the positive and negative bus bar instead of directly to the battery? If so is fusing required beyond the positive fuse from charge controller.
@tombouie
2 ай бұрын
Thks
@kkp8398
3 ай бұрын
Thanks for the great video. Practical question. I have 2x 20a mppt i want to connect them to a 250ah battery. How should I practically do that? Connect both mppt's to the battery-poles? Or first bring them together, and then with one set of wires to the battery?
@cleversolarpower
3 ай бұрын
There is a max limit on connections to battery terminals. This is a maximum of 3. If you have more, then bring them to a busbar.
@petermizon4344
Жыл бұрын
Very good explanation, I'm wiser now lol
@cinnamonoctopus
8 ай бұрын
Do both charge controllers have to be of the same rate?
@cleversolarpower
8 ай бұрын
No, they can charge at different currents. Of course they have to be the same voltage. It's the same as a charger from shore and a charge controller combined. The battery will take all the energy it can, even if it comes from multiple sources.
@takkikayo
3 ай бұрын
Can i use two different type of scc on a 200 Ah lifepo4 batteries if so do you have diagram ? And how to calibrate?
@roy196805
19 күн бұрын
What kind of set up would I need for a 3000 W pure sine inverter and 4 200 Wah AGM BATTERYS
@cleversolarpower
18 күн бұрын
Check my most popular video: how many batteries for a 3,000W inverter.
@chadrickwhite146
11 күн бұрын
Question. So my batteries reached 0% then I wake up at 4am and check them they are at 35%(series connected 12v) is that even possible
@NYCamper62
2 ай бұрын
I have 4x agm batteries, would you say the 1 controller for equalize still applies?
@Dylon1981
6 ай бұрын
I read somewhere that modern charge controllers (MPPT/PWM) can automatically detect the type of battery connected and they will automatically provide what voltage and current needed. is it true?
@cleversolarpower
6 ай бұрын
Not true. They can only detect voltage, not battery type.
@SaeedSolution
Жыл бұрын
Nice❤ I have same problem my solar panel junction box over heat and burn wire I have one battery and 2 charging source 1st is 3 solar panel in parallel 2nd is ups connect I think this is the reason of burning wire of pv modules no breaker installed between pv and charge controler
@cleversolarpower
Жыл бұрын
Yes always have a fuse or breaker installed on every wire. The fuse protects the wire from catching fire, that's it's first use.
@nehemz432
Ай бұрын
Does it matter if having two MPPT of different size, e.g. 30a + 60a. 30a having panels of 200w*2 (total of 400w) and the 60a having 500w*2 (total of 1000w). The same parallel charging a battery pack on 48v.
@cleversolarpower
Ай бұрын
No problem.
@stevemcmahon974
Жыл бұрын
Thanks, very useful information!
@Info-h3o
27 күн бұрын
Plz answer one important question for me Can we connect in parallel pwm and mppt , to charge one tubular battery. Pwm and mppt have different charging voltages, so will it cause any problem or work fine?
@cleversolarpower
27 күн бұрын
Yes, it will be ok.
@Info-h3o
27 күн бұрын
@@cleversolarpower Thanks
@brandonhayes19
5 ай бұрын
Thanks for the super detailed video, this answered most of the questions I have been searching for weeks to find! The only thing left I am wondering is do I have to match the amperage of my current charge controller? I just upgraded my tv battery from one 65ah lead acid to 2 100ah lifepo4 batteries. I have a 200w panel with a 30a charge controller currently, I am looking to add another charge controller to a suitcase panel that I can move into the sunlight as needed. Does the suitcase panel charge controller also have to be 30a or can I install a 10a or a 20a with no issues? Thank you in advance for any insight!
@cleversolarpower
4 ай бұрын
You don't have to increase the current of your charger. It will just take longer to charge the battery. However, you need to get a charger suitable for lithium batteries. As far as the charge controller, it doesn't need to have the same current. Watch my video about sizing a charge controller.
@papagiannis8235
6 ай бұрын
Hello. I have a photovoltaic system with 4 panels 340w and 4 panels 275w. at 340w I have a pwm regulator and at 275 an mppt regulator. I supply 24v batteries but the regulator mppts the 4 panel 275 no feeder at all. what should i improve in my system thanks you
@waynehobbs5175
2 жыл бұрын
Excellent thank you
@johnblack9473
11 ай бұрын
Hi I got a 300 watt solar blanket that I use on my 120ah lithium I want to get another solar blanket around 300-400 watt I don’t want to join them preferably just use another regulator for the other solar blanket will I have to use any fuses for this or it will be fine and the wires that go to the battery can I join them?
@cleversolarpower
11 ай бұрын
You dont need to fuse the solar panels. However, you need to fuse the wires going from the charge controller to the battery. Let's say your charge controller is 20A, then you need to use the following fuse: 20A*1.25=25A or higher. Then use a wire which is suited to carry 25A or more.
@baladanladiabraham6734
8 ай бұрын
Can i connect 4× tubular batteries in parallel,2× inverter in parallel, and 2× same charge controller in parallel in it possible?
@cleversolarpower
8 ай бұрын
Yes you can.
@chadrickwhite146
Ай бұрын
Can you connect pwm alongside an mppt
@cleversolarpower
Ай бұрын
Yes
@chadrickwhite146
Ай бұрын
OK thanks so much Could you also plz explain the charging Amp of a lithium battery plz because per calculation the scc Amp rating says 60a based on the 1500w input and 24v system at 100a but battery says per c-rating charge with 20a even with BMS plz explain
@rongray4118
7 ай бұрын
What would you suggest for an Absolyte GX 2,000 Amp hour/48 volt VRLA for charging OFF GRID with generator support? I have to make all the connection plates for this unit as well.
@cleversolarpower
7 ай бұрын
I'm not sure what your question is. I have a video about generators in the making.
@rongray4118
7 ай бұрын
@@cleversolarpower in regard to charging such a large VRLA - how many charge controllers would a person be limited to for charging purposes. We are on a mountaintop and roof space is limited but multiple stationary arrays with separate controllers may be able to solve our problem without having to purchase one or more trackers. I thought the price had come down on trackers but the price is still quite high.
@ilamalihilustan22
5 ай бұрын
What current MPPT controller is recommended for 24v 200ah LifePo4 battery?
@cleversolarpower
5 ай бұрын
Basically any MPPT that has a charging profile for lifepo4 batteries and work with 24V. Some brand names that come to mind are Epever, Victron, Renogy
@Rayz3ON
Жыл бұрын
Hello, here's an interesting question. what if you have one controller 12v pwm and another 24v connected mppt to 12v system? Is it possible/safe? What are the issues that can arise?
@cleversolarpower
Жыл бұрын
If you have a lithium battery with bms it will disconnect the battery. If you have a lead acid, it will cook it.
@roy196805
19 күн бұрын
I have a 30 amp m p p T controller
@mygadgetzhaiqal7410
Жыл бұрын
Can i use different charge controller brand to charge the same battery ?
@cleversolarpower
Жыл бұрын
Yes
@sebastianarceo7662
Жыл бұрын
Hi, I just want to ask if it is possible to have 2 charge controller for Hybrid of Hydro and Solar? Charging only 1 battery
@cleversolarpower
Жыл бұрын
I don't have experience with hydro, But it should be possible since its also a charging option.
@rongray4118
7 ай бұрын
Subscribed
@dPFarmville
Жыл бұрын
Hi, I have a novice question. How do I disable equalization on my lead acid battery? I have a 20a mppt solar charge controller connected to 220W (100W & 120W) panels and 100ah battery. I don’t seem to understand why my battery keeps overcarging reaching 16.1V at full sun.🥺
@cleversolarpower
Жыл бұрын
If you cannot disable it in the settings you can adjust the voltage level of the equalization function. Set that to the normal charging voltage for 100% charging.
@ekeretteekpo3004
6 ай бұрын
Kindly check your charger settings. Consult the manual and configure the charging to suit your type of lead acid battery. On mine I can choose between Sealed, Flooded, Lithium and Custom. So far, I have monitored the charging hourly and it seems to comply with the specifications from the manufacturer for my flooded lead acid battery. If yours is showing greater than 15, that's overcharging, especially if it stays that way for longer than 20 minutes. I learned that higher voltage charging tends to occur for equalisation purposes and this shouldn't take long (less than an hour).
@jhonelpernito9570
Жыл бұрын
nice
@jamesdean7756
Ай бұрын
It’s totally impossible to follow along with what you’re saying I even bought your book and found much of it to be just a waste of money a lot of overkill information not necessary for the average user to understand
@cleversolarpower
Ай бұрын
Thanks for getting my book James. If you have questions, feel free to email me.
@busarob1969
7 күн бұрын
Guru like to do this to just show you how great they are! Useless at best
@user-wm4xd6rb8v
10 ай бұрын
I see where you say a 20A controller can charge a 100A deep cycle lead battery, but I have a 6v deep cycle 225AH battery and my 100A controller won't work with it why? The pannel I am using is 590w /12v
@cleversolarpower
10 ай бұрын
You need to have a 12V battery to use with a 12V charge controller. It won't work with a 6V battery.
@user-wm4xd6rb8v
10 ай бұрын
@@cleversolarpower thank you very much for the clarification. would i be right in thinking that if I hook up booth 6v's together the 100A controller should charge both, what would be the best way to properly connect the 2 batteries together? forgive my illiteracy on this matter as it is my first time with solar systems. I bought another 100A controller as I don't think one controller can manage the 450AH when both batteries (225AH) combined as one
@markrosinski4814
9 ай бұрын
Amps your controller can handle shold be bigger than amps from your solar panels. Your solar panels 590w div 12v =~50A. What it means is that your batteries will be charged with 50A maximum minus some losses . Your 100A controller will handle 50A with ease@@user-wm4xd6rb8v
@adex2000ng
8 ай бұрын
@@user-wm4xd6rb8v connect the 2 batteries in series. That will increase the Voltage to 12v which is suitable for your Charge Controller
@ihavehotmail2
7 ай бұрын
Connect both 6v in series to increase the voltage to 12v. But the amp hours will not increase even tho you have 2 100ah batteries when in series together they will only produce 100ah @12v